Regency F39-LPG, F39-NG installation manual Copy of the Lighting Plate Instructions

Page 23

OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A) This appliance has a pilot which must be lighted

a qualified service technician. Force or attempted

by hand, following the instructions below

repair may result in a fire or explosion.

exactly.

D) Do not use this appliance if any part has been under

B) BEFORE LIGHTING smell all around the appliance

water. Immediately call a qualified service techni-

area for gas. Be sure to smell next to the floor

cian to inspect the appliance and to replace any part

because some gas is heavier than air and will

of the control system and any gas control which has

settle on the floor.

been under water.

WHAT TO DO IF YOU SMELL GAS

This appliance needs fresh air for safe operation and

- Do not try to light any appliance

must be installed so there are provisions for adequate

- Do not touch any electric switch, do not use any

combustion and ventilation air.

phone in your building

CAUTION: Hot while in operation. Do not touch.

- Immediately call your gas supplier from a

neighbors phone. Follow the gas supplier’s in-

Severe Burns may result. Due to high surface

structions.

temperatures keep children, clothing and

- If you cannot reach your gas supplier, call the

furniture, gasoline and other liquids having

fire department.

fammablevaporsaway.Keepburnerandcontrol

C)Use only your hand to push in or turn the gas compartment clean. See installation and control knob. Never use tools. If the knob will not operatinginstructionsaccompanyingappliance. push in or turn by hand, don’t try to repair it, call

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this

Release knob and it will pop back up. Pilot should

label.

 

 

 

 

remain lit. If it goes out, repeat steps 3) and 4).

1) Push in gas control knob slightly and turn

If knob does not pop up when released, stop and

clockwise

to “OFF”. Knob cannot be turned

immediately call your service technician or gas

from “PILOT” to “OFF” unless knob is pushed in

supplier.

 

 

slightly. Do

not

force.

 

 

If the pilot will not stay lit after several tries, turn the

2) Wait five (5) minutes to clear out any gas. If you

gas control knob to “OFF” and call your service

then smell gas STOP! follow “B” in the safety

technician or gas supplier.

 

 

information above on this label. If you don’t smell

5) Turn gas control knob counterclockwise

to “ON”.

gas, go to the next step.

 

6) Use rocker switch to operate main burner.

3) Turn knob

on

gas

control

counterclockwise

PILOT BURNER

 

 

to “PILOT”.

 

 

 

VEILLEUSE

 

OFF

4) Push in control

knob

all the

way and hold in.

THERMOPILE

 

 

Immediately push black button on spark igniter

 

 

ELEMENT

Gas Inlet

 

until pilot

lights. Continue to

hold the control

 

THERMO-

 

 

knob in for about 1/2 minute after the pilot is lit.

 

 

ELECTRIQUE

 

 

TO TURN OFF GAS APPLIANCE

 

1) Push in the gas control knob slightly and turn

2) Turn off all electric power to the appliance if

 

 

 

 

 

clockwise

 

 

 

 

to “OFF”. Do not force.

 

service is to be performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You may shut off the pilot during prolonged non use periods to conserve fuel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT REMOVE THIS INSTRUCTION PLATE

908-649c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

OPERATING

SOUNDS OF GAS

APPLIANCES

It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.

Blower:

Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the firebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound.This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be au- dible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

Regency® F39 Room Sealed Freestanding Gas Stove

23

Image 23
Contents 05/18/06 Please Keep These Instructions For Future ReferenceRegency F39 Room Sealed Freestanding Gas Stove Unit SpecificationsTable of Contents Safety Label Before YOU Start InstallationSpecifications General Safety InformationLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Flueing Introduction Louver InstallationInstallation Precautions Safety Precautions For the InstallerSpace Heaters Exterior Flue Termination LocationsClearance k in mm Flue Restrictor Position Fluing ArrangementsHorizontal Terminations for All Fluing Systems Optional DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation DURA-FLUE Fluing Components Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Termination KITView as possible. DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble Pipe and elbows to the ap- pliance adaptor withHole previously drilled in the ceiling, and mark DURA-FLUE Vertical TerminationCathedral Ceilings GAS Pipe Pressure TestingOffset Chart GAS ConnectionSystem Data Aeration AdjustmentValve Description System Data F39 with 40mjConversion Kit Contains Qty Description Conversion KIT #731-968 from NG to LPGConversion to Lower BTU Rating LOG SET InstallationPlace Front Left Log C02-44 onto Place the Middle Left Log B02-56 on the two pins as shownPlace Front Right Log E02-45 on the two pins as shown Final Check Front Door InstallationOptional Remote Control Optional Wall ThermostatWiring Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsGOLD-PLATED Doors MaintenanceMaintenance Instructions General Flue MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing F39 Fan FAN MaintenanceAlternate Fan Access To remove F39 fanRemoving Valve Part# Description Parts ListF39 Main Assembly DescriptionF39 Burner & LOG Assembly 936-243 Glass Gasket 650-920 Door Gasket KitCeramic Paper 940-323/P Side GlassWarranty Lifetime Warranty

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.