Regency F39-NG, F39-LPG installation manual Conversion to Lower BTU Rating, LOG SET Installation

Page 18

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.

NG Conversion Kit 730-920

Contains:

Qty. Part # Description

1904-240 Burner Orifi ce #37 (NG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

LPG Conversion Kit 730-922

Contains:

Qty. Part # Description

1904-390 Burner Orifi ce #52 (LPG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

Additional Piece (pkg. with unit:

1Log Bracket Restrictor

1)Shut off the gas supply.

2)Open the front door. Carefully remove the logs and lava rock.

3)Remove burner. See diagram below.

6)Remove burner orifi ce with a 1/2" spanner and discard.

Burner Orifi ce

7)Reinstall new burner orifi ce (NG stamped #37 or LPG stamped #52) and tighten.

8)Reverse steps 3) and 2).

9)Adjust Flue restrictor setting: To set the Flue restrictionasindicatedinthediagram,simply loosen the screws and push the fl ue restric- tor plate to the correct position. Tighten the screws.

Unit

Btu/h

Restrictor Opening

F39

40 Mj/h

A 45mm

31 Mj/h

B 35mm

Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-65 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e)02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)

Embers

902-151

i)

Lava

902-154

Note: Install Optional Brick Panels prior to installing logs.

Note: Use a magnetic

type screwdriver if

possible.

4)Unscrew the 2 Rear Log Pins and move

to the front hole posi- tion.

5)Remove Rear Log Bracketandslidethe

Log Bracket Restric- torbetweentheRear

Log Bracket and the burner, secure with the 2 screws.

Flue Restrictor set-

Flue Restrictor set-

ting at High Btu/h

ting at Low Btu/h

10)Attach the label "This unit has been con- verted to..." on top of the data badge over the higher Btu information.

11)Check for gas leaks.

12)Check inlet and outlet pressures.

13)Check operation of fl ame control. Check for proper fl ame appearance on logs.

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the fi rebox base.

EmbersEmbers

Position the Log Bracket Restrictor between

the Rear Log Bracket and the burner.

18

Regency® F39 Room Sealed Freestanding Gas Stove

Image 18
Contents Please Keep These Instructions For Future Reference 05/18/06Unit Specifications Regency F39 Room Sealed Freestanding Gas StoveTable of Contents Safety Label General Safety Information InstallationSpecifications Before YOU StartInstallation Checklist Clearances to CombustiblesLocating Your Regency GAS Stove Safety Precautions For the Installer Louver InstallationInstallation Precautions Flueing IntroductionExterior Flue Termination Locations Clearance k in mmSpace Heaters Fluing Arrangements Horizontal Terminations for All Fluing SystemsFlue Restrictor Position Qty. Description DV Stove Horizontal Flue KIT # 946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationMinimum components for a Dura-Flue Horizontal Installation DURA-FLUE Fluing ComponentsPipe and elbows to the ap- pliance adaptor with DURA-FLUE Horizontal Installations988 Wall Strap 942 Wall Thimble View as possible.DURA-FLUE Vertical Termination Hole previously drilled in the ceiling, and markGAS Connection GAS Pipe Pressure TestingOffset Chart Cathedral CeilingsSystem Data F39 with 40mj Aeration AdjustmentValve Description System DataConversion KIT #731-968 from NG to LPG Conversion Kit Contains Qty DescriptionLOG SET Installation Conversion to Lower BTU RatingPlace the Middle Left Log B02-56 on the two pins as shown Place Front Right Log E02-45 on the two pins as shownPlace Front Left Log C02-44 onto Optional Wall Thermostat Front Door InstallationOptional Remote Control Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesGeneral Flue Maintenance MaintenanceMaintenance Instructions GOLD-PLATED DoorsGlass Replacement LOG ReplacementLatch Adjustment Door GasketTo remove F39 fan FAN MaintenanceAlternate Fan Access Replacing F39 FanRemoving Valve Description Parts ListF39 Main Assembly Part# DescriptionF39 Burner & LOG Assembly 940-323/P Side Glass 650-920 Door Gasket KitCeramic Paper 936-243 Glass GasketWarranty Warranty Lifetime

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.