Regency F39-LPG Installation, Specifications, Before YOU Start, General Safety Information

Page 5

INSTALLATION

IMPORTANT

SAVE THESE

INSTRUCTIONS

The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instruc- tions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, seriousbodilyinjury,and/orproperty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

Note: These instructions take precedence over Simpson Dura-Flue instruc- tions.

SPECIFICATIONS

Fuels: F39-NG is approved for use with NG.

F39-LPG is approved for use with lique- fi ed petroleum gases (LPG).

Electrical: 240V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fi bre, 7 per set.

Flue System: Coaxial (6-5/8" outer / 4" inner liner) rigid fl ue and termination cap.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AU- THORIZED SERVICE PERSON. THISAPPLIANCE SHOULD BE IN- STALLED, REPAIRED, INSPECT- ED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORIZED SERVICE PERSON. MORE FRE- QUENT CLEANING MAY BE RE- QUIREDDUETOEXCESSIVELINT FROM CARPETING, ETC. IT IS IMPERATIVETHATTHECONTROL

COMPARTMENT, BURNERSAND CIRCULATING AIR PASSAGE- WAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFICAND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

1)Provide adequate clearances for servicing, properoperationandaroundtheairopenings into the combustion chamber.

2)The appliance may be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood fl ooring or other com- bustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The Regency® Room Sealed Freestanding Gas Stove can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

3)The Regency® Room Sealed Freestanding Gas Stove is approved for alcove installa- tions, which meet the clearances listed on page 7. This unit is approved for manufac-

tured home installations, see page 9 for the required flue arrangements. If installed into a manufactured home the unit must be bolted down to the fl oor.

4)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

5)This appliance is Listed for Alcove installa- tions, maintain minimum Alcove clearances as follows, minimum width of 48" (1219mm), a maximum depth of 36" (914mm), and minimum ceiling height of 64"(1626mm).

6)We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have an authorized building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions,local gas fi tting regulations, municipal building codes, water supply regulations, electrical wiring regulations, with AG 601 (AGA gas installation code) NZS 5261 (New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)DO NOT CONNECT TO MASONARY FLUE.

4)This appliance must be connected to the specified flue and termination cap to the outside of the building envelope. Never flue to another room or inside a building. Make sure that the flue is fitted as per Flueing instructions.

5)Inspect the flueing system annually for block- age and any signs of deterioration.

6)Flueing terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appli- ance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

Regency® F39 Room Sealed Freestanding Gas Stove

5

Image 5
Contents 05/18/06 Please Keep These Instructions For Future ReferenceRegency F39 Room Sealed Freestanding Gas Stove Unit SpecificationsTable of Contents Safety Label Specifications InstallationGeneral Safety Information Before YOU StartLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Installation Precautions Louver InstallationSafety Precautions For the Installer Flueing IntroductionSpace Heaters Exterior Flue Termination LocationsClearance k in mm Flue Restrictor Position Fluing ArrangementsHorizontal Terminations for All Fluing Systems DV Stove Horizontal Flue KIT DV Stove Horizontal Flue KIT # 946-112 InstallationQty. Description OptionalInstallation Minimum components for a Dura-Flue Horizontal Installation Planning Your Dura-Flue InstallationDURA-FLUE Termination KIT DURA-FLUE Fluing Components988 Wall Strap 942 Wall Thimble DURA-FLUE Horizontal InstallationsPipe and elbows to the ap- pliance adaptor with View as possible.Hole previously drilled in the ceiling, and mark DURA-FLUE Vertical TerminationOffset Chart GAS Pipe Pressure TestingGAS Connection Cathedral CeilingsValve Description Aeration AdjustmentSystem Data F39 with 40mj System DataConversion Kit Contains Qty Description Conversion KIT #731-968 from NG to LPGConversion to Lower BTU Rating LOG SET InstallationPlace Front Left Log C02-44 onto Place the Middle Left Log B02-56 on the two pins as shownPlace Front Right Log E02-45 on the two pins as shown Optional Remote Control Front Door InstallationOptional Wall Thermostat Final CheckWiring Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceGeneral Flue Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove F39 fan Replacing F39 FanRemoving Valve F39 Main Assembly Parts ListDescription Part# DescriptionF39 Burner & LOG Assembly Ceramic Paper 650-920 Door Gasket Kit940-323/P Side Glass 936-243 Glass GasketWarranty Lifetime Warranty

F39-LPG, F39-NG specifications

The Regency F39-LPG and F39-NG are contemporary gas fireplaces that have garnered attention for their stylish design and advanced technology. These models cater to homeowners seeking an efficient and visually appealing heating solution. Designed with both function and aesthetics in mind, the F39 series stands out for its elegant linear design, making it suitable for a variety of interior styles.

One of the distinguishing features of the F39 series is its commitment to energy efficiency. Both the F39-LPG, which operates on liquid propane, and the F39-NG, which utilizes natural gas, have been engineered to deliver optimal heat output while consuming minimal fuel. This efficiency not only reduces energy costs but also minimizes environmental impact, aligning with modern sustainable living practices.

The F39 series boasts advanced venting technology, allowing for versatile installation options. This feature enables homeowners to select the perfect location for their fireplace without compromising aesthetic appeal or functionality. The unit can be vented either vertically or horizontally, providing flexibility in design while ensuring safe and effective operation.

In terms of control, the Regency F39 models come equipped with a user-friendly remote control option. This allows for convenient operation from across the room, making it easy to adjust flame height and heat settings to create the perfect ambiance. Moreover, the models can also be connected to smart home systems, enabling homeowners to integrate their fireplace into a broader heating management system.

Aesthetically, the F39 series offers customizable options, including various media and decorative elements. Homeowners can choose from traditional logs, contemporary glass, or pebbles, allowing each unit to reflect their personal style and complement their home’s decor. The large glass viewing area enhances the visual experience, showcasing the beautiful flame patterns that add warmth and character to any room.

Durability is also a significant aspect of the design, with high-quality materials that ensure longevity and performance. The F39-LPG and F39-NG are constructed to withstand the rigors of everyday use while maintaining their sleek appearance.

In summary, the Regency F39-LPG and F39-NG fireplaces represent a blend of efficiency, technology, and elegance. With their advanced features, customizable aesthetics, and environmentally friendly operation, these models are ideal for those looking to enhance their living spaces with both warmth and style. Whether for a modern home or a more traditional setting, the F39 series is designed to meet diverse heating needs while providing a stunning focal point in any room.