Wayne JCU50 instruction manual Electrical, Chart 3 Recommended Fuse & Wiring Data 60 HZ Motors

Page 5

Operating Instructions and Parts Manual

JCU50

 

Pressure

Switch

Air

Volume

Control

Tubing

Air

Volume

Control

Figure 6 - Horizontal Tank

Air Volume Control Air

Pressure

Switch

Figure 8 - Precharged Storage Tank

CONVERTING THE DEEP WELL PUMP TO SHALLOW WELL OPERATION (FIGURE 9)

SWS50BOOST have dual voltage motors preset at the factory to 230 volts. The motors can be converted to 115 volts by turning the voltage selector to the desired voltage (See Figure 10). Use a needle nose pliers to pull the selector out approximately 1/4”, rotate and then reinsert in correct position.

Hose

Volume Control

For shallow wells (25 feet or less), a

Coupling

Figure 7 - Vertical Tank

Tubing

bolt-on shallow well jet is available as an accessory for deep well pumps. The jet attaches to the front of the pump with the two bolts provided and con- verts the deep well pump into a shal- low well pump. The shallow well jet has a 1” NPT inlet and a 1/8” NPT opening for an air volume control. For optimum performance, an incline check valve on the inlet side of the shallow well jet is

Figure 10 - Voltage Selector

Select the proper size wire and fuse (Chart 3). Time delay fuses are recom-

Installation (Cont’d)

3.Install a valve and isolating hose between the system and the house plumbing to aid in pump removal for servicing and for reducing noise trans- mitted through the house piping.

4.Provide a hose bib (faucet) at the lowest point in the system to drain for service or storage.

DEEP WELL PUMP WITH PRECHARGED STORAGE TANK (FIGURE 8)

1.

Check tank precharge using a tire

 

pressure gauge. The precharge pres-

 

sure should be 28 - 30 psi on 1/2, 3/4

 

and 1 HP models.

2.

Check the pressure with the power

recommended

To Air Volume

Control

Jet

Figure 9 - Shallow Well Jet

Electrical

Risk of electrical shock. This pump is

designed for indoor installation only.

The voltage of power supply must match the voltage of the pump. All above ground well pumps except

mended over standard fuses for motor circuit protection. All pump motors have built-in automatic overload pro- tection that will prevent damage to the motor due to overheating.

Do not connect to electric power sup- ply until unit is permanently grounded.

Connect ground wire to approved ground then connect terminal provided.

A metal underground water pipe or well casing at least 10 feet long makes the best ground electrode. If plastic pipe or insulated fittings are used, run a wire directly to the metal well casing or use a ground electrode furnished by the power company.

off, faucets open and no water

flowing (zero water pressure).

3. Install a valve and isolator hose

between the system and the house

plumbing to aid in pump removal

for servicing and for reducing noise

transmitted to the house through

the piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain

for service or storage.

CHART 3 - RECOMMENDED FUSE & WIRING DATA - 60 HZ MOTORS

 

 

 

 

 

 

 

Distance In Feet

 

 

 

 

 

 

 

 

 

 

 

From Meter To Motor

 

 

 

 

 

 

 

 

 

Dual

0

51

101

201

 

 

 

 

 

 

 

 

Element

To

To

To

To

 

 

 

 

 

Fuse

50

100

200

300

 

 

 

 

HP

Volt

250V

 

 

Wire Size

 

 

 

 

 

1/2

 

 

115

15

14

14

12

10

 

 

 

 

 

 

230

10

14

14

14

14

 

 

 

 

 

 

 

 

 

 

 

3/4

 

 

115

15

14

14

10

8

 

 

 

 

 

 

230

10

14

14

14

14

 

 

 

 

 

 

 

 

 

 

 

1

 

 

115

20

12

12

10

8

 

 

 

 

 

 

230

10

14

14

14

14

 

 

 

 

 

 

 

 

 

 

www.waynewatersystems.com

5

Image 5
Contents General Safety Information Safety GuidelinesDescription UnpackingInformation Cont’d General SafetyPre-Installation Installation Pre-Installation Cont’dDeep Well Installation Installation Cont’dElectrical Chart 3 Recommended Fuse & Wiring Data 60 HZ MotorsOperation MaintenanceInstalling NEW Shaft Seal Maintenance Cont’dLubrication Precharged TankWater Supplies Water SuppliesSymptom Possible Causes Corrective Action Troubleshooting ChartDescription JCU50-1/2 HP Qty For Replacement Parts, callModel Motor Suction Discharge Pressure psi Lift Feet PerformanceJCU50 Pump JetAttach Your Receipt Here Limited WarrantyGénéralités sur la Sécurité Directives de SécuritéDéballage Les pompes à jet sont des pompes à eauSécurité Suite Pré-InstallationGénéralités sur la Pré-Installation Suite Profond Installation SuiteInstallaiton Pour Puits Distance En Metres ’un Metre à Le Moteur Fusible 15,6 Électrique61,3 Élément Double 15,2 30,5 91,4 Volts Taille de FilFonctionnement Électrique SuiteEntretien Amorçage DE LA Pompe Pour Puits DE SurfaceEntretien Suite 20 Fr Sources d’Eau Sources d’EauSymptôme Causes Possibles Mesures Correctives Guide De DépannageRéf Description JCU50-1/2 HP Qté Pour Pièces de Rechange, appeler12,2 15,2 18,3 21,4 24,4 27,4 30,5 Para Desempacar DescripciónMedidas de Seguridad Pre-Instalación InformacionesGenerales de Seguridad Instalación Tamanos DE LOS Tubos Instalación EN UN ProfundoInstalación EN Pozos Poco ProfundosFusible 15,6 30,8 61,3 Distancia en Metros De Medidor a Motor15,2 30,5 91,4 Voltios Tamano del alambreMm 1/4, gírela y colóquela en su posición correcta EléctricasMantenimiento FuncionamientoInstalación DE UN Nuevo Sello Para Sacar EL Sello UsadoDEL EJE Figura 16 Suministros de Agua Suministros de AguaGuía de Diagnóstico de Averías Problema Posibles Causas Acción a TomarNo. de Descripción JCU50-1/2 HP Ctd Para Piezas de Repuestos, Llame alGrape SU Recibo DE Compra Aqui Rendimiento

JCU50 specifications

The Wayne JCU50 is an innovative fuel dispenser designed to meet the needs of modern fueling operations. As part of Wayne's comprehensive suite of fuel dispensing solutions, the JCU50 stands out due to its advanced features, reliable technology, and user-friendly design.

One of the main features of the Wayne JCU50 is its efficient architecture that allows for high throughput, minimizing wait times for customers. The dispenser is equipped with multiple product fueling capabilities, enabling it to handle various fuel types including gasoline, diesel, and even alternative fuels. This flexibility is crucial for service stations looking to adapt to shifting market demands and the growing popularity of biofuels and electrification.

The JCU50 utilizes smart technology, incorporating digital displays that are user-friendly and intuitive. These displays provide customers with essential information including price per gallon, total sale amount, and promotional messages, enhancing the customer experience. Additionally, the dispenser's interface is designed for easy interaction, reducing confusion at the pump.

Another critical characteristic of the Wayne JCU50 is its robust construction aimed at durability and longevity. The dispenser is designed to withstand harsh weather conditions and heavy usage, ensuring reliable operation across all environments. The materials used in its construction are resistant to corrosion, promoting a longer lifespan and reducing maintenance costs.

In terms of technology, the JCU50 integrates advanced payment solutions, supporting various payment methods such as credit cards, mobile payments, and loyalty programs. This feature not only enhances convenience for customers but also boosts sales opportunities for operators. Furthermore, the dispenser is equipped with state-of-the-art security measures to safeguard transactions and prevent fraudulent activities.

The Wayne JCU50 also emphasizes sustainability. With increasing regulatory pressures around emissions and environmental responsibility, the dispenser supports eco-friendly practices, making it easier for fuel retailers to comply with new regulations.

Overall, the Wayne JCU50 represents a sophisticated solution for fuel dispensers, marrying efficiency with technology and sustainability. Its myriad features and durable design make it an excellent choice for fuel retailers looking to modernize their operations while enhancing customer satisfaction and boosting sales.