Nortec Industries manual GS Series Internal Components Spare Parts

Page 68

GS Series Internal Components Spare Parts

Number

Description

Part #

GS 100

GS 200

GS 300

GS 400

GS 500

GS 600

 

 

 

 

 

 

 

 

 

101

Cover Plate, Clean-Out Port

2523457

1

1

2

2

3

3

 

 

 

 

 

 

 

 

 

102

Gasket, Tank Cover Plate

2524361

1

1

2

2

3

3

 

 

 

 

 

 

 

 

 

103

Secondary Safety Switch

1504832

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

104

Fill Box

2526152

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

105

Vacuum Break Valve ½” npt

1505959

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

106

P-Trap

2526521

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

107

Dual Fill Valve 10.0 l/min & 0.35 l/min

1505759

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

108

Heat Exchanger Gasket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single

2524405

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual

2524403

 

1

2

2

3

3

 

 

 

 

 

 

 

 

 

109

Direct Vent Air Manifold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 100

1506140

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 200

1506141

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 300/400

1506142

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

GS 500/600

1506143

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

110

Heat Exchanger Replacement Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mini

2528422

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single

2528423

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

Dual

2528424

 

1

1

2

2

3

 

 

 

 

 

 

 

 

 

111

Stack High Limit Switch

1506745

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

112

Exhaust Manifold Gasket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single

1505973

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual

1505942

 

1

2

2

3

3

 

 

 

 

 

 

 

 

 

113

Exhaust Manifold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 100

1505875

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 200

1505861

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GS 300/400

1505843

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

GS 500/600

1505828

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

114

Flexible Gas Hose with fittings

1505960

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

115

Auxillary Drain Plug

1507043

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

116

Auxillary Drain Termination

1506925

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

117

Drain Pump 24v 60 hz

1502644

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

118

Tank Thermal Sensor

1506026

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

119

Float Chamber

1115933

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

120

Float Chamber Mounting Bracket

1113777

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

121

Float Board

2521137

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

122

Lower Mixing Box

1506749

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

123

Replacement Burner Ass’y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110-120V Models

2528416

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

 

208-240V Models

1507669

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

124

Burner Plate Gasket

1505936

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

125

Sight Port Replacement Kit

2528417

1

2

3

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 64 -

Image 68
Contents Installation User & Maintenance Guide For Your Safety Table Of Contents Principle of Operation General Specifications DeliveryReceiving & Unpacking Equipment Model DesignationModel Specification Figure #1 Typical Installation Indoor Locating and Mounting Side ClearanceGAS Piping GASCombustion AIR Requirements Direct Vent GuidelinesExhaust Venting General RequirementsFigure #7 Vertical Venting Application Using B or BH Venting Figure # Co-venting Application Using B Vent Only Installation as a Category I Appliance Recommended B-Venting ManufacturersBH Vent Manufacturers Installation as a Category III ApplianceAdditional Requirements When Venting Through a Sidewall Electrical Primary WiringLOW Voltage Control Wiring 600V/3ph 5 6 7 8 9 10 11 12 13 14 15 16 17 Control Installation PlumbingFill Water Supply Line Drain LineGS Outdoor Installation AUX Drain PortSteam Lines and Condensate Line MountingFigure # Gstc Outdoor Typical Installation Rooftop TOP GAS Piping Figure #17 Gas PipingElectrical Installation Exhaust Venting Outdoor UnitsFigure #21 Fill Water Connection Auxiliary DrainSteam Lines CombustionWater Management Start UP Procedure START-UP ChecklistTesting the Ignition Safety SHUT-OFF Filling the SystemStarting the Humidifier Taking OUT of OperationGS Inspection Check List Supply Water Line Factory for more informationScale Management Water QualitySafety Instructions Fault ConditionsDraining the Tank Gstc ModelsMandatory Maintenance Schedule Cleaning the Steel Tank Figure #26 Cleaning Tank AccessBurner Service Checks Combustion BlowerServicing the Unit Burner Removal and Installation Consult Factory Prior to the Replacement of ANY ComponentHot Surface Igniter and Flame Sensor Replacement Removal and Installation of the Combustion Blower Gas Valve ReplacementAir Switch Replacement Float Chamber ReplacementFill Valve Replacement Ignition Module ReplacementTransformer Replacement Drain Pump Replacement Fill Box ReplacementFigure #38 Heat Exchange Assembly Removal of Heat ExchangerPage Maintenance GSP DAY DrainKeep Warm Analog ChannelMaintenance Shutdown Input ChannelTime Proportioning Blowdown GSPNortec TC Controller Main Menu System Status User Settings Status Lockout System Status 1System Status Service Interval System Status 2Service Level 1 Main Menu System Status Service Level User SettingsService Level 2 User Settings 1 User Settings 2 Main Menu System Status Service Level User SettingsUser Settings 3 TypeService Level password protected User Settings password protectedDiagnostics safety loop protected Product nameScreen Service interval Safety sensorsRemaining Start DateService history Service LevelService interval Fault history Tank DrainBurners Tank Pre-CleanShort Cycle Delay User Settings Date / Time UnitsTime of day DateFtbd Hours Language ControlsWater Management Float Check Ftbd HourBlowdown Rate Fill Corrctn correction Drain Corrctn correctionDrain Cool Control InputCalibrate Transducer InputCapacity Limit Fault List Fault GIF-X See Fault List Page GS Series Internal Components Spare Parts Igniter / flame sensor gasket Page GS Series Indoor Cabinetry Spare Parts GS Series Outdoor Cabinetry Exploded View GS Outdoor Spare Parts List Page InstructionsAssembly GS Quick Reference Limited Warranty Walter Meier Climate USA Inc

GS Series specifications

Nortec Industries has established itself as a leader in the field of industrial automation, particularly with the introduction of its GS Series. This series is designed to cater to the needs of a diverse range of industries, providing advanced solutions for modern manufacturing challenges. The GS Series embodies a perfect blend of technology, precision, and versatility, designed to enhance productivity and efficiency.

One of the standout features of the GS Series is its modular design. This allows for easy customization and scalability, making it a suitable choice for businesses of any size. Users can configure their systems to meet specific operational requirements, ensuring that they get the most out of their investment. The modularity of the GS Series enables companies to start small and expand their operations as needed without extensive overhauls.

Another key characteristic of the GS Series is its incorporation of cutting-edge technologies. This series leverages artificial intelligence and machine learning algorithms to optimize production processes. These technologies enable the system to learn from real-time data, making adjustments that can significantly boost efficiency and reduce waste. Furthermore, the GS Series features advanced sensors and automation tools that allow for precise monitoring and control of manufacturing processes, ensuring that quality standards are consistently met.

The GS Series is also built with robust connectivity options, allowing for seamless integration with existing enterprise systems. This interoperability is crucial in today’s fast-paced business environment, where data-driven decision-making is key to maintaining a competitive edge. The ability to connect with Internet of Things (IoT) devices enhances the flexibility of the GS Series, enabling manufacturers to gather and analyze data from multiple sources for more informed operations.

Safety features are paramount in the design of the GS Series. Nortec Industries prioritizes the well-being of its operators by incorporating numerous safety protocols and fail-safes within the system. These features not only comply with industry standards but also ensure that operations can continue without interruptions caused by safety concerns.

In summary, Nortec Industries' GS Series represents a significant advancement in industrial automation. With its modular design, integration of AI and machine learning, robust connectivity, and inherent safety features, the GS Series is poised to drive efficiency and productivity across various sectors. Companies looking to enhance their manufacturing capabilities would find the GS Series an invaluable asset in navigating the complexities of modern production environments.