Fan Hood

 

1507811

1

1

1

1

1

1

26

Cover Plate Top Panel

 

1508109

1

1

1

1

1

1

27

Gasket, Steamline

100

1508105

1

 

 

 

 

 

 

 

200/300

1507872

 

1

1

 

 

 

 

 

400/500/600

1507871

 

 

 

1

1

1

28

Cover Plate Steam Line

100

1508106

1

 

 

 

 

 

 

 

200/300

1507870

 

1

1

 

 

 

 

 

400/500/600

1507810

 

 

 

1

1

1

29

Step-up transformer (120/240V option)

1508167

1

1

1

1

1

1

30

Mounting bracket, step-up transformer

1507759

1

1

1

1

1

1

31

Mid Cross Member

Mini

1506958

1

 

 

 

 

 

 

 

Single

1506978

 

1

 

 

 

 

 

 

Double

1506983

 

 

1

1

 

 

 

 

Triple

1506972

 

 

 

 

1

1

32

Gas Line Bracket

 

1506960

1

1

2

2

2

2

33

Rear Frame Element

 

1506963

1

1

1

1

1

1

34

Rear Panel

 

1507785

1

1

1

1

1

1

35

Cross Member

Mini

1506957

2

 

 

 

 

 

 

 

Single

1506979

 

2

 

 

 

 

 

 

Double

1506981

 

 

2

2

 

 

 

 

Triple

1506971

 

 

 

 

2

2

36

Mounting bracket, float chamber

1508114

1

1

1

1

1

1

37

Front Frame

 

1506959

1

1

1

1

1

1

38

Right Panel

Mini

1508087

1

 

 

 

 

 

 

 

Single

1508097

 

1

 

 

 

 

 

 

Double

1507862

 

 

1

1

 

 

 

 

Triple

1507803

 

 

 

 

1

1

39

Access Door, Side

 

1507801

1

 

 

 

 

 

 

 

 

1507800

 

1

 

 

2

2

 

 

 

1507860

 

 

1

1

 

 

40

Base Assembly

Mini

1508123

1

 

 

 

 

 

 

 

Single

1508122

 

1

 

 

 

 

 

 

Double

1508017

 

 

1

1

 

 

 

 

Triple

1508018

 

 

 

 

1

1

41

Lifting Lug

 

1507901

4

4

4

4

4

4

42

Pump House Heater 500 watts

1508039

1

1

2

2

3

3

43

Mounting Bar Pump House Heater, Mini

1508113

2

 

 

 

 

 

 

 

Single

1508112

 

2

 

 

 

 

 

 

Double

1508111

 

 

2

2

 

 

 

 

Triple

1508164

 

 

 

 

2

2

44

Strapping, Pump House Heater

1508110

1

1

2

2

3

3

- 70 -

Image 74
Contents Installation User & Maintenance Guide For Your Safety Table Of Contents Principle of Operation Receiving & Unpacking Equipment General SpecificationsDelivery Model DesignationModel Specification Figure #1 Typical Installation Indoor Locating and Mounting Side ClearanceGAS Piping GASCombustion AIR Requirements Direct Vent GuidelinesExhaust Venting General RequirementsFigure #7 Vertical Venting Application Using B or BH Venting Figure # Co-venting Application Using B Vent Only Installation as a Category I Appliance Recommended B-Venting ManufacturersBH Vent Manufacturers Installation as a Category III ApplianceAdditional Requirements When Venting Through a Sidewall Electrical Primary WiringLOW Voltage Control Wiring 600V/3ph 5 6 7 8 9 10 11 12 13 14 15 16 17 Fill Water Supply Line Control InstallationPlumbing Drain LineSteam Lines and Condensate Line GS Outdoor InstallationAUX Drain Port MountingFigure # Gstc Outdoor Typical Installation Rooftop TOP GAS Piping Figure #17 Gas PipingElectrical Installation Exhaust Venting Outdoor UnitsFigure #21 Fill Water Connection Auxiliary DrainSteam Lines CombustionWater Management Testing the Ignition Safety SHUT-OFF Start UP ProcedureSTART-UP Checklist Filling the SystemStarting the Humidifier Taking OUT of OperationGS Inspection Check List Supply Water Line Factory for more informationScale Management Water QualityDraining the Tank Safety InstructionsFault Conditions Gstc ModelsMandatory Maintenance Schedule Cleaning the Steel Tank Figure #26 Cleaning Tank AccessBurner Service Checks Combustion BlowerServicing the Unit Burner Removal and Installation Consult Factory Prior to the Replacement of ANY ComponentHot Surface Igniter and Flame Sensor Replacement Removal and Installation of the Combustion Blower Gas Valve ReplacementAir Switch Replacement Float Chamber ReplacementFill Valve Replacement Ignition Module ReplacementTransformer Replacement Drain Pump Replacement Fill Box ReplacementFigure #38 Heat Exchange Assembly Removal of Heat ExchangerPage Keep Warm Maintenance GSPDAY Drain Analog ChannelTime Proportioning Maintenance ShutdownInput Channel Blowdown GSPNortec TC Controller Main Menu System Status User Settings Status Lockout System Status 1System Status Service Interval System Status 2Service Level 1 Main Menu System Status Service Level User SettingsService Level 2 User Settings 1 User Settings 2 Main Menu System Status Service Level User SettingsUser Settings 3 TypeDiagnostics safety loop protected Service Level password protectedUser Settings password protected Product nameScreen Remaining Service intervalSafety sensors Start DateService history Service LevelService interval Fault history Tank DrainBurners Tank Pre-CleanShort Cycle Delay Time of day User SettingsDate / Time Units DateFtbd Hours Language ControlsWater Management Float Check Ftbd HourBlowdown Rate Drain Cool Fill Corrctn correctionDrain Corrctn correction Control InputCalibrate Transducer InputCapacity Limit Fault List Fault GIF-X See Fault List Page GS Series Internal Components Spare Parts Igniter / flame sensor gasket Page GS Series Indoor Cabinetry Spare Parts GS Series Outdoor Cabinetry Exploded View GS Outdoor Spare Parts List Page InstructionsAssembly GS Quick Reference Limited Warranty Walter Meier Climate USA Inc

GS Series specifications

Nortec Industries has established itself as a leader in the field of industrial automation, particularly with the introduction of its GS Series. This series is designed to cater to the needs of a diverse range of industries, providing advanced solutions for modern manufacturing challenges. The GS Series embodies a perfect blend of technology, precision, and versatility, designed to enhance productivity and efficiency.

One of the standout features of the GS Series is its modular design. This allows for easy customization and scalability, making it a suitable choice for businesses of any size. Users can configure their systems to meet specific operational requirements, ensuring that they get the most out of their investment. The modularity of the GS Series enables companies to start small and expand their operations as needed without extensive overhauls.

Another key characteristic of the GS Series is its incorporation of cutting-edge technologies. This series leverages artificial intelligence and machine learning algorithms to optimize production processes. These technologies enable the system to learn from real-time data, making adjustments that can significantly boost efficiency and reduce waste. Furthermore, the GS Series features advanced sensors and automation tools that allow for precise monitoring and control of manufacturing processes, ensuring that quality standards are consistently met.

The GS Series is also built with robust connectivity options, allowing for seamless integration with existing enterprise systems. This interoperability is crucial in today’s fast-paced business environment, where data-driven decision-making is key to maintaining a competitive edge. The ability to connect with Internet of Things (IoT) devices enhances the flexibility of the GS Series, enabling manufacturers to gather and analyze data from multiple sources for more informed operations.

Safety features are paramount in the design of the GS Series. Nortec Industries prioritizes the well-being of its operators by incorporating numerous safety protocols and fail-safes within the system. These features not only comply with industry standards but also ensure that operations can continue without interruptions caused by safety concerns.

In summary, Nortec Industries' GS Series represents a significant advancement in industrial automation. With its modular design, integration of AI and machine learning, robust connectivity, and inherent safety features, the GS Series is poised to drive efficiency and productivity across various sectors. Companies looking to enhance their manufacturing capabilities would find the GS Series an invaluable asset in navigating the complexities of modern production environments.