Nortec Industries GS Series manual User Settings, Date / Time Units, Time of day

Page 59

User Settings

DATE/TIME/UNITS

LANGUAGE CONTROLS

WATER MANAGEMENT

CONTROL TYPE

CAPACITY LIMIT

CALIBRATE

When a parameter requires a change, press the two arrow keys and enter the password (0335). As long as you remain in this section, you will not need to enter the password more than once.

Date / Time Units

This field is used for modifying the Date, time and the units of measurement. The date and time are important parameters when features such as full tank blowdown are enabled.

DATE/TIME/UNITS

LANGUAGE CONTROLS

WATER MANAGEMENT

CONTROL TYPE

 

1

CAPACITY LIMIT

CALIBRATE

Time (of day)

TIME HH:MM

DATE MM.DD.YY

UNITS: LB/HR

CHANGE TIME

0335 XX:XX

 

 

 

 

 

 

CHANGE DATE

 

 

 

 

 

 

MM.DD.YY

 

 

 

 

 

 

0335

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT UNITS

0335

LB/HR

 

KG/HR

To set the time of day, highlight the selection then enter the user code (0335). Press enter. Use the UP/DOWN arrows to adjust the hours (24 hour format). Pressing enter saves the setting and indexes the display to minutes. Use the UP/DOWN arrows to adjust the minutes. Pressing enter saves the setting and returns the user to the previous menu.

Date

To set the date, highlight the selection then enter the user code (0335). Press enter. Use the UP/DOWN arrows to select the month. Pressing enter saves the setting and indexes the display to number of the month. Use the UP/DOWN arrows to adjust the number. Pressing enter saves the setting and indexes the display to year. Use the UP/DOWN arrows to adjust the year. Pressing enter saves the setting and returns the user to the previous menu.

Units

Here the user can select the unit of steam production rate. To set the units, highlight the selection then enter the user code (0335). Press enter. Use the UP/DOWN arrows to select the units (LB/HR or KG/HR). Pressing enter saves the setting and returns the user to the previous menu.

- 55 -

Image 59
Contents Installation User & Maintenance Guide For Your Safety Table Of Contents Principle of Operation Model Designation General SpecificationsDelivery Receiving & Unpacking EquipmentModel Specification Figure #1 Typical Installation Indoor Side Clearance Locating and MountingGAS GAS PipingDirect Vent Guidelines Combustion AIR RequirementsGeneral Requirements Exhaust VentingFigure #7 Vertical Venting Application Using B or BH Venting Figure # Co-venting Application Using B Vent Only Recommended B-Venting Manufacturers Installation as a Category I ApplianceBH Vent Manufacturers Installation as a Category III ApplianceAdditional Requirements When Venting Through a Sidewall Electrical Primary WiringLOW Voltage Control Wiring 600V/3ph 5 6 7 8 9 10 11 12 13 14 15 16 17 Drain Line Control InstallationPlumbing Fill Water Supply LineMounting GS Outdoor InstallationAUX Drain Port Steam Lines and Condensate LineFigure # Gstc Outdoor Typical Installation Rooftop TOP Figure #17 Gas Piping GAS PipingExhaust Venting Outdoor Units Electrical InstallationAuxiliary Drain Figure #21 Fill Water ConnectionSteam Lines CombustionWater Management Filling the System Start UP ProcedureSTART-UP Checklist Testing the Ignition Safety SHUT-OFFTaking OUT of Operation Starting the HumidifierGS Inspection Check List Factory for more information Supply Water LineWater Quality Scale ManagementGstc Models Safety InstructionsFault Conditions Draining the TankMandatory Maintenance Schedule Figure #26 Cleaning Tank Access Cleaning the Steel TankBurner Service Checks Combustion BlowerServicing the Unit Burner Removal and Installation Consult Factory Prior to the Replacement of ANY ComponentHot Surface Igniter and Flame Sensor Replacement Gas Valve Replacement Removal and Installation of the Combustion BlowerFloat Chamber Replacement Air Switch ReplacementFill Valve Replacement Ignition Module ReplacementTransformer Replacement Fill Box Replacement Drain Pump ReplacementRemoval of Heat Exchanger Figure #38 Heat Exchange AssemblyPage Analog Channel Maintenance GSPDAY Drain Keep WarmBlowdown GSP Maintenance ShutdownInput Channel Time ProportioningNortec TC Controller System Status 1 Main Menu System Status User Settings Status LockoutSystem Status 2 System Status Service IntervalMain Menu System Status Service Level User Settings Service Level 1Service Level 2 User Settings 1 Main Menu System Status Service Level User Settings User Settings 2Type User Settings 3Product name Service Level password protectedUser Settings password protected Diagnostics safety loop protectedScreen Start Date Service intervalSafety sensors RemainingService history Service LevelService interval Tank Drain Fault historyBurners Tank Pre-CleanShort Cycle Delay Date User SettingsDate / Time Units Time of dayFtbd Hours Language ControlsWater Management Float Check Ftbd HourBlowdown Rate Control Input Fill Corrctn correctionDrain Corrctn correction Drain CoolCalibrate Transducer InputCapacity Limit Fault List Fault GIF-X See Fault List Page GS Series Internal Components Spare Parts Igniter / flame sensor gasket Page GS Series Indoor Cabinetry Spare Parts GS Series Outdoor Cabinetry Exploded View GS Outdoor Spare Parts List Page InstructionsAssembly GS Quick Reference Limited Warranty Walter Meier Climate USA Inc

GS Series specifications

Nortec Industries has established itself as a leader in the field of industrial automation, particularly with the introduction of its GS Series. This series is designed to cater to the needs of a diverse range of industries, providing advanced solutions for modern manufacturing challenges. The GS Series embodies a perfect blend of technology, precision, and versatility, designed to enhance productivity and efficiency.

One of the standout features of the GS Series is its modular design. This allows for easy customization and scalability, making it a suitable choice for businesses of any size. Users can configure their systems to meet specific operational requirements, ensuring that they get the most out of their investment. The modularity of the GS Series enables companies to start small and expand their operations as needed without extensive overhauls.

Another key characteristic of the GS Series is its incorporation of cutting-edge technologies. This series leverages artificial intelligence and machine learning algorithms to optimize production processes. These technologies enable the system to learn from real-time data, making adjustments that can significantly boost efficiency and reduce waste. Furthermore, the GS Series features advanced sensors and automation tools that allow for precise monitoring and control of manufacturing processes, ensuring that quality standards are consistently met.

The GS Series is also built with robust connectivity options, allowing for seamless integration with existing enterprise systems. This interoperability is crucial in today’s fast-paced business environment, where data-driven decision-making is key to maintaining a competitive edge. The ability to connect with Internet of Things (IoT) devices enhances the flexibility of the GS Series, enabling manufacturers to gather and analyze data from multiple sources for more informed operations.

Safety features are paramount in the design of the GS Series. Nortec Industries prioritizes the well-being of its operators by incorporating numerous safety protocols and fail-safes within the system. These features not only comply with industry standards but also ensure that operations can continue without interruptions caused by safety concerns.

In summary, Nortec Industries' GS Series represents a significant advancement in industrial automation. With its modular design, integration of AI and machine learning, robust connectivity, and inherent safety features, the GS Series is poised to drive efficiency and productivity across various sectors. Companies looking to enhance their manufacturing capabilities would find the GS Series an invaluable asset in navigating the complexities of modern production environments.