Daewoo DSB-071LH, Split Airconditioning System owner manual Black

Page 12

INSTALLATION (CONTINUED)

INSTALLING THE INDOOR/OUTDOOR WIRE TO THE OUTDOOR UNIT FOR AC CONNECTION

The Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire, follow the procedures below.

1.Remove the screw holding on the connection cover. Remove the connection cover on the outdoor unit to access the connection area.

Connection

Cover

2.Route the indoor/outdoor wire into the opening on the outdoor unit and through the wire holder. To con- nect to the wire holder, loosen the screw on the wire holder, insert the wires through, then tighten the screw.

Use the wire as shown below:

Brown

Yellow/Green

Blue

Blue

Black

3.Connect the wires to the housing and terminals on the Control board individually according to the out- door unit Connection.

Housing & Terminals on the

Main PCB

 

 

 

 

 

 

 

Terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indoor unit

 

 

 

L

 

 

 

 

 

Y

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.To connect wires, loosen the screw in the Terminal Block and insert the correct wires like following fig- ure. Connect the Brown wire to the “L” connection, Yellow/Green wire to the “ ” connection, the Blue wire to “Y” connection, the Blue wire to “1” connec- tion and the Black wire to “2” connection. Insert Housing “A” and Housing “B” to connection.

<OUTDOOR UNIT(Control Panel)>

color of wires

color of wires

Housing A

Brown

Yellow/

Blue

Blue

Black

Green

BLACK GRAY

BLACK GRAY

Brown

Yellow/

Blue

Blue

Black

Green

Housing

B

L

Y

1

2

 

 

 

Housing

 

 

 

A

Brown Yellow

Blue

 

Black

Housing & Terminals on the

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

Y

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outdoor unit

Housing B

 

 

 

 

 

Terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Make sure the Indoor unit’s AC cord is not connected to AC power when connecting the indoor/outdoor wire.

When connecting wires, make sure they are fully insert- ed and minimum copper wire is exposed. If they are not, shorting, overheating, no operation, etc. may occur.

Be sure to comply with local codes on running a wire from the indoor to the outdoor unit.

/Green

Blue

 

 

 

 

 

 

Clamp Cord

1)

2)Connection

Cable Cover 3)

The used connection cable connected to indoor and outdoor unit must be ;

1) H07RN-F 3G1.5mm2 (NOT INCLUDED)

2) H07RN-F 2G1.5mm2 (NOT INCLUDED)

3) UL2464 AWG22 2G0.75mm2 (INCLUDED IN SET)

11

Image 12
Contents DSB-071LH Safety Instructions Important NotesContents Basic Accessories Accessories Supplied with the UnitWall Bracket Concrete Nails Remote Controller Copper TubingOptional Accessories Accessories not Supplied with the UnitAccessories 1, 2, 3, 4, 5, 6, 7 Description Qty Material SizeInstallation Diagram OverviewInstallation Installing the Wall BracketSelecting a Site Brown Blue Blue Black Yellow/Green Mounting the Indoor Unit Connecting Copper Tubes To connect the copper tubes, follow the procedures belowPreparing the Copper Tubing not Included Connecting the Drain Hose To connect the drain hose, follow the procedures belowBlack Tubing AIR Purging AIR Purging with Vacuum Pump Test RUNLeak Test Evacuation Finishing the jobTest RUN Pump DownAir Cleaning Filters LCD Remote ControllerLocation of Controls Indoor UnitIndoor Unit Display Remote Controller Remote DisplayConnecting the AC Cord Setting the Unit for Remote OperationThree Minute Compressor Delay OperationHOW to Install Batteries Celsius to Fahrenheit Conversion ChartTo SET the Unit to Auto Mode SET Unit to Quick ModeTo SET Unit to Cool Mode FAN SpeedsTo SET Unit to Dehumidifier Mode To Operate FAN onlyTo SET Unit to Heat Mode To Select the FAN DirectionTo SET the on Timer Mode To SET the OFF Timer ModePress the Timer OFF button once to enter the Timer screen Play. For example, if it is 800 P.M.To SET Unit to Sleep Mode To Cancel Sleep ModeEmergency Operation CHANGING/CLEANING the AIR Filters Cleaning the Indoor CoverInsert cleaned or new black fil- ters back into the unit Care and Maintenance PrecautionsAfter the Season Before the SeasonTroubleshooting Guide Symptoms Possible Cause Possible SolutionsPush EMERGENCY/REMOTE Specifications Model