INSTALLATION (CONTINUED)
INSTALLING THE INDOOR/OUTDOOR WIRE TO THE INDOOR UNIT FOR AC CONNECTION
The Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire, follow the procedures below.
1.Open the connection cover on the indoor unit to ac- cess the connection area.
Connection cover
Remove the Connection
Cover.
• Loosen one screw for fixing the Connection Cover.
•Loosen one screw at the Connection Cover.
•Remove the Connection Cover.
Screw
2.Fish the indoor/outdoor wire from the rear of the in- door unit through the front of the unit.
For easier connection, make sure enough wire is pulled through the front.
Use the wire as shown below:
Brown
Yellow/Green
Blue
Blue
Black
3.To connect wires, loosen the screw in the Terminal Block and insert the correct wires like following fig-
ure. Connect the Brown wire to the “L” connection, Yellow/Green wire to the “ ” connection, the Blue wire to “Y” connection, the Blue wire to “1” connec- tion and the Black wire to “2” connection.
NOTES:
•This appliance must be installed according to National power supply requirement.
•If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qual- ified person in order to avoid a hazard.
•Make sure the Indoor unit’s AC cord is not connected to AC power when connecting the indoor/outdoor wire.
•When connecting wires, make sure they are fully insert- ed and minimum copper wire is exposed. If they are not, shorting, overheating, no operation, etc. may occur.
•Be sure to comply with local codes on running a wire from the indoor to the outdoor unit.