Daewoo DSB-071LH, Split Airconditioning System owner manual Specifications, Model

Page 30

 

SPECIFICATIONS

 

 

 

 

MODEL

DSB-071LH

 

 

 

 

 

Function

 

Cooling / Heating (Heat pump)

 

 

 

 

Power Supply

 

AC 220-240V, 50Hz

 

 

 

 

Cooling Capacity (Heating)

1,688 Kcal/h (1,764 Kcal/h)

 

 

 

 

 

Operating Current (Heating Mode)

3.0 A (3.2 A)

 

 

 

 

 

Power Consumption (Heating Mode)

676 W (693 W)

 

 

 

 

 

Indoor Unit Dimensions

W 750 x H 240 x D 174 mm

 

 

 

 

Outdoor Unit Dimensions

W 654 x H 549 x D 256 mm

 

 

 

 

Net Weight

Indoor

7.0 kg

 

 

 

Outdoor

34 kg

 

 

 

 

 

Connection

Type

Flare

 

 

 

Gas

1/2" (12.7 mm)

the piping

 

 

 

Liquid

1/4" (6.35 mm)

 

 

 

 

 

Air Cleaning

 

Anti-bacteria Filter, (Electrostatic Filter, Deodorizing Filter Option)

 

 

 

 

Operating

Indoor side (Heating Mode)

min 21˚C ~ max 32˚C (min 15˚C ~ max 27˚C)

Condition

 

 

 

Outdoor side (Heating Mode)

min 21˚C ~ max 43˚C (min -5˚C ~ max 24˚C)

 

 

 

 

Design and specification are subject to change without notice for product improvemont.

S/N : 3103901701

29

Image 30
Contents DSB-071LH Safety Instructions Important NotesContents Wall Bracket Concrete Nails Remote Controller Basic AccessoriesAccessories Supplied with the Unit Copper TubingAccessories 1, 2, 3, 4, 5, 6, 7 Optional AccessoriesAccessories not Supplied with the Unit Description Qty Material SizeInstallation Diagram OverviewInstallation Installing the Wall BracketSelecting a Site Brown Blue Blue Black Yellow/Green Mounting the Indoor Unit Connecting Copper Tubes To connect the copper tubes, follow the procedures belowPreparing the Copper Tubing not Included Connecting the Drain Hose To connect the drain hose, follow the procedures belowBlack Tubing AIR Purging AIR Purging with Vacuum Pump Test RUNLeak Test Evacuation Finishing the jobTest RUN Pump DownLocation of Controls Air Cleaning FiltersLCD Remote Controller Indoor UnitIndoor Unit Display Remote Controller Remote DisplayThree Minute Compressor Delay Connecting the AC CordSetting the Unit for Remote Operation OperationHOW to Install Batteries Celsius to Fahrenheit Conversion ChartTo SET Unit to Cool Mode To SET the Unit to Auto ModeSET Unit to Quick Mode FAN SpeedsTo SET Unit to Dehumidifier Mode To Operate FAN onlyTo SET Unit to Heat Mode To Select the FAN DirectionPress the Timer OFF button once to enter the Timer screen To SET the on Timer ModeTo SET the OFF Timer Mode Play. For example, if it is 800 P.M.To SET Unit to Sleep Mode To Cancel Sleep ModeEmergency Operation CHANGING/CLEANING the AIR Filters Cleaning the Indoor CoverInsert cleaned or new black fil- ters back into the unit After the Season Care and MaintenancePrecautions Before the SeasonTroubleshooting Guide Symptoms Possible Cause Possible SolutionsPush EMERGENCY/REMOTE Specifications Model