INSTALLATION DIAGRAM
Below is an overview for the connection of the the Indoor unit to the Outdoor unit. The pages following will give detailed instructions for full installation. Remember to read the complete Installation section and follow all the safety instructions fully when installing the Indoor and Outdoor units.
OVERVIEW
This appliance must be installed according to national power supply aequirement.
10cm (3.95in) from ceiling
10cm (3.95in) from
side wall
30cm (11.8in) from
side wall
At least 30cm (11.8in) from unit
AC Outlet
and Plug
Plug into 220V
AC Outlet
23.6 | 60 | |
cm | ||
inches | ||
|
| Wall |
|
Wall | Drain |
|
Bracket | Hose | Wall Cap |
|
|
Pipes
(Not Supplied)
AC
Connection
(Not Supplied)
Wrap with
Tape
Maximum Height 7M(21Ft)
Maximum Length 15M(49Ft)
Any tube length between 7 and 15 meters must
be precharged with freon using the following calulation:
(Length – 5) x 30 grams
Adding additonal tubing will decrease efficiency
10 cm
3.9 inches
NOTES:
•After installation it must be possi- ble for the user to disconnect the power supply plug.
•If the AC outlet is a
•Contanct service man when re- place the power cord set.
•The specification of AC connection is 1.5mm2X5PX6m.
|
| 27.6 |
|
|
| 70 | inches |
| |
| cm |
|
| |
|
|
| Copper | Drain |
|
|
| Tubing | |
|
|
| Hose | |
|
|
|
| |
60 | 23.6 |
|
|
|
cm |
|
|
| |
inches |
|
|
| |
|
|
| 1/2" side piping | |
| Connecting |
|
| |
| cable |
| 1/4" side piping | |
|
|
| Drain Hose |
5