INSTALLATION DIAGRAM

Below is an overview for the connection of the the Indoor unit to the Outdoor unit. The pages following will give detailed instructions for full installation. Remember to read the complete Installation section and follow all the safety instructions fully when installing the Indoor and Outdoor units.

OVERVIEW

This appliance must be installed according to national power supply aequirement.

10cm (3.95in) from ceiling

10cm (3.95in) from

side wall

30cm (11.8in) from

side wall

At least 30cm (11.8in) from unit

AC Outlet

and Plug

Plug into 220V

AC Outlet

23.6

60

cm

inches

 

 

Wall

 

Wall

Drain

 

Bracket

Hose

Wall Cap

 

 

Pipes

(Not Supplied)

AC

Connection

(Not Supplied)

Wrap with

Tape

Maximum Height 7M(21Ft)

Maximum Length 15M(49Ft)

Any tube length between 7 and 15 meters must

be precharged with freon using the following calulation:

(Length – 5) x 30 grams

Adding additonal tubing will decrease efficiency

10 cm

3.9 inches

NOTES:

After installation it must be possi- ble for the user to disconnect the power supply plug.

If the AC outlet is a 3-pronged type or other, have an electrician install a new outlet.

Contanct service man when re- place the power cord set.

The specification of AC connection is 1.5mm2X5PX6m.

 

 

27.6

 

 

 

70

inches

 

 

cm

 

 

 

 

 

Copper

Drain

 

 

 

Tubing

 

 

 

Hose

 

 

 

 

60

23.6

 

 

 

cm

 

 

 

inches

 

 

 

 

 

 

1/2" side piping

 

Connecting

 

 

 

cable

 

1/4" side piping

 

 

 

Drain Hose

5

Image 6
Contents DSB-071LH Safety Instructions Important NotesContents Wall Bracket Concrete Nails Remote Controller Basic AccessoriesAccessories Supplied with the Unit Copper TubingAccessories 1, 2, 3, 4, 5, 6, 7 Optional AccessoriesAccessories not Supplied with the Unit Description Qty Material SizeInstallation Diagram OverviewInstallation Installing the Wall BracketSelecting a Site Brown Blue Blue Black Yellow/Green Mounting the Indoor Unit Connecting Copper Tubes To connect the copper tubes, follow the procedures belowPreparing the Copper Tubing not Included Connecting the Drain Hose To connect the drain hose, follow the procedures belowBlack Tubing AIR Purging AIR Purging with Vacuum Pump Test RUNLeak Test Evacuation Finishing the jobTest RUN Pump DownLocation of Controls Air Cleaning FiltersLCD Remote Controller Indoor UnitIndoor Unit Display Remote Controller Remote DisplayThree Minute Compressor Delay Connecting the AC CordSetting the Unit for Remote Operation OperationHOW to Install Batteries Celsius to Fahrenheit Conversion ChartTo SET Unit to Cool Mode To SET the Unit to Auto ModeSET Unit to Quick Mode FAN SpeedsTo SET Unit to Dehumidifier Mode To Operate FAN onlyTo SET Unit to Heat Mode To Select the FAN DirectionPress the Timer OFF button once to enter the Timer screen To SET the on Timer ModeTo SET the OFF Timer Mode Play. For example, if it is 800 P.M.To SET Unit to Sleep Mode To Cancel Sleep ModeEmergency Operation CHANGING/CLEANING the AIR Filters Cleaning the Indoor CoverInsert cleaned or new black fil- ters back into the unit After the Season Care and MaintenancePrecautions Before the SeasonTroubleshooting Guide Symptoms Possible Cause Possible SolutionsPush EMERGENCY/REMOTE Specifications Model