Daewoo DSB-071LH owner manual Connecting the AC Cord, Setting the Unit for Remote Operation

Page 20

OPERATION

CONNECTING THE AC CORD

The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the in- door unit to AC, follow the procedures below:

1.Insert the attached AC plug into a pronged 220V AC outlet.

AC Outlet

and Plug

Plug into 220V AC Outlet.

NOTES:

Never connect the AC line cord plug to other than the specified voltage (220V).

Use the attached power cord only.

The new air conditioner system should be on it’s own 220V circuit. Contact your local electrical installer for in- stallation.

SETTING THE UNIT FOR REMOTE OPERATION

After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation, follow the procedures below:

1.Open the indoor unit’s cover and make sure the EMERGENCY/REMOTE switch is set to the RE- MOTE position; this will allow the unit to operate with the remote controller.

EMERGENCY/REMOTE Switch

2.Press the ON/OFF button on the remote controller to turn on the unit. The On LED will light on the indoor unit and “ON” will light in the remote display.

To select the various modes and settings, read the following pages.

EMR. REMOCON

THREE MINUTE COMPRESSOR DELAY

After turning the indoor unit on and setting it for air con- ditioner operation, the compressor (outdoor unit) will not come on for three minutes. This is a feature that will protect the compressor from damage due to quick start and stops.

19

Image 20
Contents DSB-071LH Safety Instructions Important NotesContents Basic Accessories Accessories Supplied with the UnitWall Bracket Concrete Nails Remote Controller Copper TubingOptional Accessories Accessories not Supplied with the UnitAccessories 1, 2, 3, 4, 5, 6, 7 Description Qty Material SizeInstallation Diagram OverviewSelecting a Site InstallationInstalling the Wall Bracket Brown Blue Blue Black Yellow/Green Mounting the Indoor Unit Preparing the Copper Tubing not Included Connecting Copper TubesTo connect the copper tubes, follow the procedures below Connecting the Drain Hose To connect the drain hose, follow the procedures belowBlack Tubing Leak Test AIR PurgingAIR Purging with Vacuum Pump Test RUN Evacuation Finishing the jobTest RUN Pump DownAir Cleaning Filters LCD Remote ControllerLocation of Controls Indoor UnitIndoor Unit Display Remote Controller Remote DisplayConnecting the AC Cord Setting the Unit for Remote OperationThree Minute Compressor Delay OperationHOW to Install Batteries Celsius to Fahrenheit Conversion ChartTo SET the Unit to Auto Mode SET Unit to Quick ModeTo SET Unit to Cool Mode FAN SpeedsTo SET Unit to Dehumidifier Mode To Operate FAN onlyTo SET Unit to Heat Mode To Select the FAN DirectionTo SET the on Timer Mode To SET the OFF Timer ModePress the Timer OFF button once to enter the Timer screen Play. For example, if it is 800 P.M.Emergency Operation To SET Unit to Sleep ModeTo Cancel Sleep Mode Insert cleaned or new black fil- ters back into the unit CHANGING/CLEANING the AIR FiltersCleaning the Indoor Cover Care and Maintenance PrecautionsAfter the Season Before the SeasonPush EMERGENCY/REMOTE Troubleshooting GuideSymptoms Possible Cause Possible Solutions Specifications Model