Daewoo Split Airconditioning System, DSB-071LH owner manual Connecting the Drain Hose

Page 11

INSTALLATION (CONTINUED)

3.Once a smooth match is made, tighten the flare nut using a wrench. Be very careful not to strip the threads or flare nut. Repeat this process for the small and large tubing. When tightening the flare nut, use another wrench to securely hold the coupler from twisting and possibly damaging the tubing.

4.Remove the flare nut stoppers from the outdoor unit’s valves. Connect the larger copper tubing to the larger valve on the outdoor unit. Connect the smaller copper tubing to the smaller valve on the outdoor unit.

5.Perform a leak test on all copper tube connections. To prevent heat loss and damage to walls from con- densation, the copper tube connections coming from the wall must be insulated. Do this by wrapping foam rubber or equivalent around the connection approxi- mately 8mm thick so no copper tubing is exposed.

NOTES:

As with all wiring and hookups on this unit, make sure the AC plug on the indoor unit is unplugged.

Be very careful not to strip the threads or flare nut.

When insulating the connections, use foam rubber or equivalent.

CONNECTING THE DRAIN HOSE

To connect the drain hose, follow the procedures below:

1.Connect the drain hose extension to the drain hose coming from the indoor unit by loosing the clamp on the extension using a phillips screwdriver, attaching the hoses together and then tightening the clamp.

2.Run the drain hose, slanted downward, outside. If the drain pipe is exposed indoors, make sure it is thoroughly insulated so condensation does not ruin walls or furniture or come in contact with the AC con- nection or extension. Also, do not crease or form a trap in the tubing.

Wall Bracket

Insert Putty

Drain Hose

10

Image 11
Contents DSB-071LH Important Notes Safety InstructionsContents Copper Tubing Basic AccessoriesAccessories Supplied with the Unit Wall Bracket Concrete Nails Remote ControllerDescription Qty Material Size Optional AccessoriesAccessories not Supplied with the Unit Accessories 1, 2, 3, 4, 5, 6, 7Overview Installation DiagramSelecting a Site InstallationInstalling the Wall Bracket Brown Blue Blue Black Yellow/Green Mounting the Indoor Unit Preparing the Copper Tubing not Included Connecting Copper TubesTo connect the copper tubes, follow the procedures below To connect the drain hose, follow the procedures below Connecting the Drain HoseBlack Tubing Leak Test AIR PurgingAIR Purging with Vacuum Pump Test RUN Finishing the job EvacuationPump Down Test RUNIndoor Unit Air Cleaning FiltersLCD Remote Controller Location of ControlsIndoor Unit Display Remote Display Remote ControllerOperation Connecting the AC CordSetting the Unit for Remote Operation Three Minute Compressor DelayCelsius to Fahrenheit Conversion Chart HOW to Install BatteriesFAN Speeds To SET the Unit to Auto ModeSET Unit to Quick Mode To SET Unit to Cool ModeTo Operate FAN only To SET Unit to Dehumidifier ModeTo Select the FAN Direction To SET Unit to Heat ModePlay. For example, if it is 800 P.M. To SET the on Timer ModeTo SET the OFF Timer Mode Press the Timer OFF button once to enter the Timer screenEmergency Operation To SET Unit to Sleep ModeTo Cancel Sleep Mode Insert cleaned or new black fil- ters back into the unit CHANGING/CLEANING the AIR FiltersCleaning the Indoor Cover Before the Season Care and MaintenancePrecautions After the SeasonPush EMERGENCY/REMOTE Troubleshooting GuideSymptoms Possible Cause Possible Solutions Model Specifications