K. DIAGRAMS FOR VERTICAL VENTING
ROOF VENT WITH TEE (INTAKE)
AND COUPLING (EXHAUST)
STRAIGHT
COUPLING
24" MIN.
TEE
12" OVER MAXIMUM SNOW LEVEL OR 24"
WHICHEVER IS GREATER
SUPPORT BRACKETS
MUST BE USED ON
ALL HORIZONTAL
AND VERTICAL PIPING
INTAKE AIR
VENT
RIGHT SIDE VIEW | EXTERIOR WALL |
EXHAUST |
|
VENT |
|
ROOF VENT WITH TEE (INTAKE)
AND COUPLING (EXHAUST)
EXHAUST VENT |
|
(STRAIGHT |
|
COUPLING) | 24" MIN. |
12" OVER MAXIMUM
SNOW LEVEL OR 24"
WHICHEVER IS GREATER
INTAKE AIR VENT (TEE)
SUPPORT BRACKETS
MUST BE USED ON
ALL HORIZONTAL
AND VERTICAL PIPING
ROOF VENT WITH
CONCENTRIC VENT KIT
12" OVER MAXIMUM SNOW LEVEL OR 24"
WHICHER IS GREATER
SUPPORT BRACKETS
MUST BE USED ON
ALL HORIZONTAL
AND VERTICAL PIPING
INTAKE AIR
VENT
EXHAUST
VENT
RIGHT SIDE VIEW | EXTERIOR WALL |
ROOF VENT WITH
CONCENTRIC VENT KIT
12" OVER MAXIMUM SNOW LEVEL OR 24"
WHICHEVER IS GREATER
SUPPORT BRACKETS
MUST BE USED ON
ALL HORIZONTAL
AND VERTICAL PIPING
RIGHT SIDE
VIEW
RIGHT SIDE
VIEW
EXTERIOR WALL
Figure
EXTERIOR WALL
Figure
NOTE: When placing support brackets on vent piping, the first bracket must be within 1 foot of the appliance and the balance at 4 foot invervals on the vent pipe. The boiler venting must be readily accessible for visual inspection for the first three feet from the boiler.
GENERAL NOTE: All vent pipes must be glued, properly supported and the exhaust must be pitched a minimum of a ¼" per foot back to the heater (to allow drainage of condensate).
44