Lochinvar 400-801 operation manual Ratings, Outdoor Knight XL Boiler Ahri Rating

Page 7

Ratings

Outdoor Knight XL Boiler

AHRI Rating

Model Number

 

Input

 

Net

 

MBH

Gross

AHRI

 

 

 

 

 

 

Output

Ratings

Note: Change “N” to

 

(Note 4)

MBH

Water,

 

 

 

 

MBH

“L” for L.P. gas models.

 

 

 

 

Min

 

Max

 

 

 

(Note 1)

(Note 2)

OKN400

80

 

399

370

322

OKN501

100

 

500

463

402

OKN601

120

 

600

566

493

OKN701

140

 

700

658

572

OKN801

160

 

800

748

651

 

 

 

 

 

 

Outdoor Knight XL Installation & Operation Manual

Other Specifications

Boiler Water

Water

Gas

 

Content

Air Size

Connections

Connections

Gallons

 

 

 

 

 

 

 

3.4

1-1/2"

1"

4"

 

 

 

 

4.2

1-1/2"

1"

4"

 

 

 

 

4.2

2"

1"

4"

 

 

 

 

5.0

2"

1"

4"

 

 

 

 

5.7

2"

1"

4"

 

 

 

 

NOTICE

Notes:

Maximum allowed working pressure is located on the rating plate.

1.The ratings are based on standard test procedures prescribed by the United States Department of Energy.

2.Net AHRI ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15.

3.Standard Outdoor Knight XL boilers are equipped to operate from sea level to 4,500 feet only with no adjustments. The boiler will de-rate by 4% for each 1,000 feet above sea level up to 4,500 feet.

4.Ratings have been confirmed by the Hydronics Section of AHRI.

5.Outdoor Knight XL boilers comply with the requirements of CSD-1 Section CW-400 requirements as a temperature operation control. The manual reset high limit provided with the Outdoor Knight XL is listed to UL353.

7

Image 7 Contents
Outdoor Knight XL Models 400 Contents Please read before proceeding When servicing boilerStainless steel heat exchanger Outdoor Knight XL How it worksModel Models 601 Outdoor Knight XL Boiler Ahri Rating RatingsDetermine boiler location Installation must comply withBefore locating the boiler, check Prevent combustion air contamination Provide clearancesOutdoor vent / air intake location Flooring and foundationPrepare boiler Install flue pipe assembly Models 400Remove boiler from wood pallet Models 701 3Install flue pipe assembly Models 701Gas conversions Model 4Installing Propane Orifice ModelLeveling the boiler Models 601Hydronic piping TEE with 1 Fitting on TOP Nipple Close Nipple Near boiler piping components Flow switch adjustmentCirculator sizing Near boiler piping connectionsVariable speed pump option Pressure Head Feet20F 25F 30F 35F Model 7Single Boiler Multiple Temperatures 8Single Boiler Primary/Secondary Piping Manifold Pipe Sizes in Inches mm Number of Units10Multiple Boilers Primary/Secondary Piping Temperature Wires to Loop Sensors 120VAC to Gas connections Connecting gas supply pipingPropane Gas Natural gasInches Check inlet gas supplyGas pressure Gas valve replacementLow voltage connections Field wiringInstallation must comply with Line voltage connectionsThermostat Outdoor temperature sensorHigh gas pressure switch Low gas pressure switchModBus Flow switchAlarm contacts Wiring of the cascade3Low Voltage Field Wiring Connections Condensate drain Condensate disposalFill and test water system Freeze protection when usedStart-up Check/control water chemistryInspect/check condensate lines and fittings Check for gas leaksCheck thermostat circuits Inspect/fill condensate systemCheck system and boiler Final checks before starting the boilerStart the boiler If boiler does not start correctlyFor Your Safety Read Before Operating Natural Gas Propane Set space heating operationSet domestic hot water DHW operation Verify DHW modeConfiguration of the cascade How the control module operates Operating informationGeneral How the boiler operatesProtection features Temperature controlBoiler temperature regulation Cascade Outdoor reset operation, if usedOperation Display Sequence of operationStandby, ready to start a new cycle User Access modesInstaller Outdoor Knight XL control moduleCall for Heat Information Dial Function Service technician Maintenance Maintenance and annual startupOwner maintenance Maintenance Check boiler relief valve Flue vent system and air pipingCheck water system Check expansion tankInspect ignition and flame sense electrodes Check ignition ground wiringCheck all boiler wiring Check control settingsModel Kit Part Component Number Description Check flame signalCleaning boiler heat exchanger Review with ownerHigh Voltage Diagrams2Ladder Diagram