Bradford-White Corp BRHHH, BRHHV warranty Βρυτε Μαγνυμ

Page 1

Installation and Operation Instructions

Docyment 1246

 

 

Installation and Operation

Instructions for

ΒΡΥΤΕ ΜΑΓΝΥΜ

Modulating Boiler

Model BRHHH

Modulating Water Heater

Model BRHHV

U.S. Patent No. 6,644,393

Canada Patent Pending

FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler and heater installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a nearby phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or gas

AVERTISSEMENT

Assurez-vous de bien suivres les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

Ne pas tenter d’allumer d’appareils.

Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones dansle bâtiment où vous vous trouvez.

Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.

L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.

H2343400-

238-49223-00A REV 4/11

Image 1
Contents Βρυτε Μαγνυμ Βραδφορδ Ωηιτε Χορπ Maintenance Table of ContentsTroubleshooting Replacement PartsList of Figures List of TablesIntroduction General InformationModel Identification Model DesignationDimensions WarrantyLocating the Appliance Inches 91cm horizontally Combustion Air Venting and Combustion AIRCombustion Air From Room Intake Combustion AirLocating Vent & Combustion Air Terminals VentingHorizontal Vent Terminal Combustion Air and Vent Through Side Wall From Massachusetts Rules and Regulations 248 CMR Installation of Carbon Monoxide DetectorsSide Wall Combustion Air Terminal Common Vent Test BoilersVertical Vent Terminal Vertical Combustion Air TerminalDistance from Gas Meter or Last Stage Regulator GAS Supply and Piping4A.1 Heating System Piping Hot Supply Connections Boiler Water Connections Brute Magnum Boiler4A.2 Cold Water Make-Up Boiler 4A.3 Freeze Protection Boiler Water Connections Brute Magnum Water Heater4B.1 Water System Piping Water Heater 4B.2 Hot Water Supply Piping Water HeaterHydronic Piping Multiple Boilers 4B.3 Water Flow Requirements Water HeaterHydronic Piping Multiple Boilers Alternate 4B.4 Combined Water potable Heating and Space Heating Hydronic Piping One Boiler, Multi-Temperature System4B.5 Freeze Protection Water Heater Heater or in the pipes in the system. When waterWater Heater Piping One Heater, One Tank Water Heater Piping Multiple Heaters, One Tank Water Heater Piping One Heater, Multiple Tanks Water Heater Piping Multiple Heaters, Multiple Tanks Temperature Control Boiler Main PowerTemperature Control Water Heater Electrical ConnectionsInternal Water Heater Temperature Control Temperature Control FeaturesTemperature Setpoint Differential SettingThrottling Range OffsetIntegration Constant Minimum Output SettingControl Parameter Possible Interference Mixing System and ControlExternal Control Connections Wiring DiagramsWiring Diagram, Size 1200, Standard and Codes a and F Βρυτε Μαγνυμ Wiring Diagram, Size 1200, Code B Wiring Diagram, Sizes 1600, 2000 and 2400, Code B Wiring Schematic, Model 1200, Standard and Codes a and F Wiring Schematic, Model 1200, Code B Operating Instructions Operating the Burner and Set UpFilling the Boiler System Gas/Air Test Panel System Maintenance MaintenanceAppliance Maintenance Component Description Shutting Down the Brute MagnumGas Trains Filter BurnerModulating Gas Valve Manual Reset High Limit Control Safety Gas ValveAuto Reset Temperature Limit Mixing ControlFlow Switch Ignitor / Flame Sensor AssemblyMixing Actuator Ignition ControlMotorized Safety Valve TroubleshootingGas Pressure Switches Sequence of OperationResolving Lockouts Delayed Ignition Possible CausesShort Cycling Boiler Short Cycling Water Heater Replacement PartsHigh Gas Consumption Combustion Components See Figure Parts ListElectrical Components See Figure Jacket See Figure Combustion Components Gas Train/Combustion Air Components Gas Train Components Electrical Components Heat Exchanger / Water Path Components Heat Exchanger / Water Path Components Jacket Components Litho in U.S.A. Bradford White 1102 Document