Burnham 81433101R16-1/10 manual VI. Oil Piping, General, Single-pipe Oil Lines

Page 21

VI. Oil Piping

A.General

1.Use flexible oil line(s) so that Swing Door can be opened without disconnecting oil supply.

2.A supply line fuel oil filter is recommended as a minimum for all firing rates but a pleated paper fuel oil filter is recommended for the lowest (.6 GPH) firing rate application to prevent nozzle fouling.

3.Use Flared fittings only. Do not use compression fittings.

4.Use of a high efficiency micron oil filter (Garber or equivalent) in addition to conventional filter is highly recommended.

B.Single-pipe Oil Lines.

1.Standard burners are provided with single-stage 3450 rpm fuel units with the bypass plug removed for single-pipe installations.

2.The single-stage fuel unit may be installed single- pipe with gravity feed or lift. Maximum allowable lift is 8 feet. See Figure 16.

NOTICE

Single-pipe installations must be absolutely airtight or leaks or loss of prime may result. Bleed line and fuel unit completely.

Table 2: Single-Stage Units (3450 RPM) - Two Pipe Systems

 

Maximum Length of Tubing

Lift "H"

"H" + "R"

3/8" OD

1/2" OD

 

 

Tubing (3 GPH)

Tubing (3 GPH)

 

 

 

0'

84'

100'

 

 

 

1'

78'

100'

 

 

 

2'

73'

100'

 

 

 

3'

68'

100'

 

 

 

4'

63'

100'

 

 

 

5'

57'

100'

 

 

 

6'

52'

100'

 

 

 

7'

47'

100'

 

 

 

8'

42'

100'

 

 

 

9'

36'

100'

 

 

 

10'

31'

100'

 

 

 

11'

26'

100'

 

 

 

12'

21'

83'

 

 

 

13'

---

62'

 

 

 

14'

---

41'

 

 

 

Figure 16: Single-Pipe Installation

21

Image 21
Contents 81433101R16-1/10 Price $3.00 Ledv SeriesImportant Information Read Carefully Page Table of Contents Water Content 6.1 gallons Pre-Installation II. Unpack Boiler Do not drop boiler. Do not bump boiler jacketAgainst floor Minimum Clearances to Combustible Materials III. Water Piping and Trim Page Page General Guidelines IV. Venting / Air Intake PipingIntake Terminal Location Vent Pipe Part NumbersVent Installation Vent Connector, Assembled Air Intake Installation Direct Vent only See Figure Page Electrical and Sequence of Operations Electrical Sequence of Operations Beckett Burner Schematic Wiring Diagram Page VI. Oil Piping GeneralSingle-pipe Oil Lines Two-Pipe Oil Lines Two-Pipe InstallationAdjusting Settings Always Inspect Installation Before Starting BurnerVII. System Start-up Ii. DisplayControl Operating Characteristics LED Error CodesBurner START-UP Install Pressure Gauge Riello BF Burner SettingsCheck / Adjust OIL Pressure Remove Test Plug in Flue CollarHints on Combustion Test Controls Simulate power failureSimulate flame failure Simulate ignition failurePage Section Viii Service and Cleaning Firetubes and Combustion ChamberBurner Low water cutoff if so equipped Avoid Breathing Fiber Particulates and Dust Ledv Boiler Trim & Controls IX. Repair PartsLedv Boiler Jacket & Insulation Ledv Bare Boiler Assembly PartsRepair KitVent Beckett Afii Oil Burner Repair Part Beckett Afii Burner Replacement Parts Service Record Wiring of Typical Lwco Low Water Cut Off Lwco on Hot Water BoilersLwco Location Limited Warranty