Burnham 81433101R16-1/10 manual Avoid Breathing Fiber Particulates and Dust

Page 31

Important Product Safety Information

Refractory Ceramic Fiber Product

Warning:

The Repair Parts list designates parts that contain refractory ceramic fibers (RCF). RCF has been classified as a possible human carcinogen. When exposed to temperatures about 1805°F, such as during direct flame contact, RCF changes into crystalline silica, a known carcinogen. When disturbed as a result of servicing or repair, these substances become airborne and, if inhaled, may be hazardous to your health.

AVOID Breathing Fiber Particulates and Dust

Precautionary Measures:

Do not remove or replace RCF parts or attempt any service or repair work involving RCF without wearing the following protective gear:

1.A National Institute for Occupational Safety and Health (NIOSH) approved respirator

2.Long sleeved, loose fitting clothing

3.Gloves

4.Eye Protection

Take steps to assure adequate ventilation.

Wash all exposed body areas gently with soap and water after contact.

Wash work clothes separately from other laundry and rinse washing machine after use to avoid contaminating other clothes.

Discard used RCF components by sealing in an airtight plastic bag. RCF and crystalline silica are not classified as hazardous wastes in the United States and Canada.

First Aid Procedures:

If contact with eyes: Flush with water for at least 15 minutes. Seek immediate medical attention if irritation persists.

If contact with skin: Wash affected area gently with soap and water.

Seek immediate medical attention if irritation persists.

If breathing difficulty develops: Leave the area and move to a location with clean fresh air. Seek immediate medical attention if breathing difficulties persist.

Ingestion: Do not induce vomiting. Drink plenty of water. Seek immediate medical attention.

31

Image 31
Contents 81433101R16-1/10 Price $3.00 Ledv SeriesImportant Information Read Carefully Page Table of Contents Water Content 6.1 gallons Pre-Installation Do not drop boiler. Do not bump boiler jacket II. Unpack BoilerAgainst floor Minimum Clearances to Combustible Materials III. Water Piping and Trim Page Page General Guidelines IV. Venting / Air Intake PipingIntake Terminal Location Vent Pipe Part NumbersVent Installation Vent Connector, Assembled Air Intake Installation Direct Vent only See Figure Page Electrical Electrical and Sequence of OperationsSequence of Operations Beckett Burner Schematic Wiring Diagram Page General VI. Oil PipingSingle-pipe Oil Lines Two-Pipe Oil Lines Two-Pipe InstallationIi. Display Always Inspect Installation Before Starting BurnerAdjusting Settings VII. System Start-upLED Error Codes Control Operating CharacteristicsBurner START-UP Remove Test Plug in Flue Collar Riello BF Burner SettingsInstall Pressure Gauge Check / Adjust OIL PressureHints on Combustion Simulate ignition failure Simulate power failureTest Controls Simulate flame failurePage Firetubes and Combustion Chamber Section Viii Service and CleaningBurner Low water cutoff if so equipped Avoid Breathing Fiber Particulates and Dust Ledv Boiler Trim & Controls IX. Repair PartsLedv Boiler Jacket & Insulation Ledv Bare Boiler Assembly PartsRepair KitVent Beckett Afii Oil Burner Repair Part Beckett Afii Burner Replacement Parts Service Record Low Water Cut Off Lwco on Hot Water Boilers Wiring of Typical LwcoLwco Location Limited Warranty