FIRELARM 2500 Operating Manual

 

 

Secondary

Secondary Function Description

Function

 

(DELETE)

Deletes the value at the cursor location when entering numeric values.



Numeric entry of 1.



Numeric entry of 2.



Numeric entry of 3.



Numeric entry of 4.



Numeric entry of 5.



Numeric entry of 6.



Numeric entry of 7.



Numeric entry of 8.



Numeric entry of 9.



Numeric entry of 0.

(YES)

Confirm change of data.

(NO)

Abort change of data.

(comma)

Enter 2-second delay for ZDACT phone number.

2.2Visual indicators (LEDs)

The LED’s give immediate visual indication of panel status.

Figure 2-2. FireLarm 2500 LED label

2-2

Image 10
Contents Operating Manual CPG #2561255 Firelarm 2500 Operating Manual Warranty Overview CPG #2561255 Firelarm 2500 Operating ManualMaintenance Overview System featuresGeneral description Housing SpecificationsElectrical specifications ZdactService use NFPA-72 Listings and approvalsCPG #2561255 IRE L ARM 2500 Operating Manual Touchpad OperationPrimary Primary Function Description Contents Silence and reset operation Normal Standby ConditionSupervisory trouble 6 … Initiating circuit alarmNAC trouble / silence Initiating zone troubleAC power conditions Auxiliary power output conditionsBattery power conditions System troubleCPG #2561255 IRE L ARM 2500 Operating Manual Safety message to installers InstallationNfpa and UL installation requirements Requirements for Central Station Fire Alarm Systems Installing the cabinet and optional bezelBattery size requirements WiringZonal Digital Alarm Communicator Transmitter optional Zdact Using the Calculation Table TableCurrent Requirements Motherboard Device Wiring Diagram Notification Appliance Circuits ConnectionsCPG #2561255 IRE L ARM 2500 Operating Manual 1 B1 Strobe device Configuration and ProgrammingSelecting connected device options DIP switches 2 B1 Temporal patternProgram configuration of the panel Setup ZONES? Order of charactersZdact configuration Setup ZDACT?AC Delay HR Password settings Number KeysInspection and Test procedure MaintenanceAuto Reset feature One-man test Testing the control panelTesting the Remote Annunciator Remote Annunciator with Liquid Crystal Display 2500-RALCD Appendix A. Optional AccessoriesKey Function Control When Active Electrical ConnectionsZonal Digital Alarm Communicator Transmitter 2500-ZDACT Figure A-2. Zdact MountingStyle Z Class a Module for NAC circuits CAM Transient Protected Built in 5.1K END of Line ResistorMaster Box Module Model MBM Figure A-5. MBMInstallation MBMCPG #2561255 IRE L ARM 2500 Operating Manual Appendix B. Smoke Detector Compatibility ESL MAX. NO. of Detectors PER Zone isContents Appendix C. NAC Compatibility Contents Base Components Model No Description Stock No Replacement Parts Model No Description Stock NoAppendix D. Ordering Information Options Model No Description Stock NoContents Appendix E. Quick Reference Operating Instructions FireLarm Contents