CPG manual Overview, CPG #2561255 Firelarm 2500 Operating Manual

Page 3

CPG #2561255

FIRELARM 2500 Operating Manual

 

Contents

1 Overview

1-1

1.1

General description

1-1

1.2

System features

1-1

1.3

Specifications

1-2

1.3.1

Electrical specifications

1-2

1.3.2

Housing

1-2

1.3.3

Service use: NFPA-72

1-3

1.3.4

Listings and approvals

1-3

2 Operation

2-1

2.1

Touchpad

2-1

2.2

Visual indicators (LEDs)

2-2

2.3

Normal Standby Condition

2-3

2.4

Silence and reset operation

2-3

2.4.1 Silencing a non-normal condition (buzzer or NAC)

2-3

2.4.2 Resetting an alarm condition

2-3

2.4.3 Resetting a trouble condition

2-3

2.5

Alarm, trouble, and supervisory conditions (by panel LED label)

2-3

2.5.1

Ground fault

2-3

2.5.2

Annunciator trouble

2-3

2.5.3 NAC trouble / silence

2-4

2.5.4

Supervisory trouble

2-4

2.5.5

Initiating zone trouble

2-4

2.5.6 …..............................................................................................................................................2-4

2.5.7

Initiating circuit alarm

2-4

2.5.8 Auxiliary power output conditions

2-5

2.5.9

Battery power conditions

2-5

2.5.10

AC power conditions

2-5

2.5.11

System trouble

2-5

2.5.12 Supervisory initiating device circuit

2-5

3 Installation

3-1

3.1

Safety message to installers

3-1

3.2

NFPA and UL installation requirements

3-1

3.2.1 Requirements for all installations

3-1

3.2.2 Requirements for Local Fire Alarm Systems

3-1

3.2.3 Requirements for Auxiliary Fire Alarm Systems

3-1

3.2.4 Requirements for Remote Station Fire Alarm Systems

3-1

3.2.5 Requirements for Central Station Fire Alarm Systems

3-2

3.3

Installing the cabinet (and optional bezel)

3-2

3.4

Wiring

3-3

3.5

Quick Reference Operating Instructions form

3-3

3.6

Zonal Digital Alarm Communicator Transmitter (optional ZDACT)

3-3

3.7

Battery size requirements

3-3

3.8

Notification Appliance Circuits Connections

3-7

4 Configuration and Programming

4-1

4.1 Selecting connected device options (DIP switches)

4-1

i

Contents

1

2

3

4

5

A

B

C

D

Image 3
Contents Operating Manual CPG #2561255 Firelarm 2500 Operating Manual Warranty CPG #2561255 Firelarm 2500 Operating Manual OverviewMaintenance System features OverviewGeneral description Zdact SpecificationsElectrical specifications HousingListings and approvals Service use NFPA-72CPG #2561255 IRE L ARM 2500 Operating Manual Operation TouchpadPrimary Primary Function Description Contents Normal Standby Condition Silence and reset operationInitiating zone trouble 6 … Initiating circuit alarmNAC trouble / silence Supervisory troubleSystem trouble Auxiliary power output conditionsBattery power conditions AC power conditionsCPG #2561255 IRE L ARM 2500 Operating Manual Installation Safety message to installersNfpa and UL installation requirements Installing the cabinet and optional bezel Requirements for Central Station Fire Alarm SystemsUsing the Calculation Table Table WiringZonal Digital Alarm Communicator Transmitter optional Zdact Battery size requirementsCurrent Requirements Motherboard Device Wiring Notification Appliance Circuits Connections DiagramCPG #2561255 IRE L ARM 2500 Operating Manual 2 B1 Temporal pattern Configuration and ProgrammingSelecting connected device options DIP switches 1 B1 Strobe deviceProgram configuration of the panel Order of characters Setup ZONES?Setup ZDACT? Zdact configurationAC Delay HR Number Keys Password settingsTesting the control panel MaintenanceAuto Reset feature One-man test Inspection and Test procedureTesting the Remote Annunciator Electrical Connections Appendix A. Optional AccessoriesKey Function Control When Active Remote Annunciator with Liquid Crystal Display 2500-RALCDFigure A-2. Zdact Mounting Zonal Digital Alarm Communicator Transmitter 2500-ZDACTTransient Protected Built in 5.1K END of Line Resistor Style Z Class a Module for NAC circuits CAMFigure A-5. MBM Master Box Module Model MBMMBM InstallationCPG #2561255 IRE L ARM 2500 Operating Manual ESL MAX. NO. of Detectors PER Zone is Appendix B. Smoke Detector CompatibilityContents Appendix C. NAC Compatibility Contents Options Model No Description Stock No Replacement Parts Model No Description Stock NoAppendix D. Ordering Information Base Components Model No Description Stock NoContents Appendix E. Quick Reference Operating Instructions FireLarm Contents