FIRELARM 2500 Operating Manual

Appendix E. Quick Reference Operating

Instructions

FireLarm 2500

Normal Standby

Green AC indicator on. All other indicators off.

Alarm Conditions

Red zone indicator on. Audible/visual signaling indicator

 

operating

To Silence Alarm

Do not silence alarm until it has been determined that an

 

emergency situation does not exist (panel must be reset to

 

silence waterflow alarms). Open cover and press . This will

 

also cause the bell trouble indicator to flash.

To Reset an Alarm

After condition that caused alarm has been corrected, press

 

.

Trouble Conditions

Yellow SYSTEM TROUBLE indicator and buzzer on. Yellow

 

indicator for specific trouble on (battery, zone, trouble, etc.)`

Supervisory Condition

Yellow SYSTEM TROUBLE indicator and buzzer on. Yellow

 

SUPERVISORY indicator on (valve closed, low air, low

 

temperature, etc.)

To Silence Trouble

Open cover and press . The panel automatically restores

Devices

to normal when the trouble condition has been corrected.

 

Some trouble conditions require pressing for restoration.

 

Note: The problem must be corrected as soon as possible as

 

this may make system inoperative. Contact your service

 

organization if necessary.

To Test Alarm

Notify building occupants (if a fire department or other

 

monitoring agency, such as a Central Station alarm company,

 

monitors alarms, they must also be notified). Open cover,

 

press and hold for 2 seconds.

This system should be thoroughly inspected on a regular basis in accordance with the NFPA-72 National Fire Alarm Code and the authority having jurisdiction. Contact the agency listed below for this service.

For Service, Call

Name:

Address:

Telephone:

INSTALLER: FRAME THIS SHEET AND PLACE ADJACENT TO CONTROL PANEL

CPG Signals

2519 4th Ave., P.O. Box 590, Moline, IL 61265

(800)577-5758 / (309) 762-0731 / FAX (309) 762-8215 www.cpglifesafety.com

E

E-1

Image 43
Contents Operating Manual CPG #2561255 Firelarm 2500 Operating Manual Warranty CPG #2561255 Firelarm 2500 Operating Manual OverviewMaintenance Overview System featuresGeneral description Zdact SpecificationsElectrical specifications HousingListings and approvals Service use NFPA-72CPG #2561255 IRE L ARM 2500 Operating Manual Touchpad OperationPrimary Primary Function Description Contents Normal Standby Condition Silence and reset operationInitiating zone trouble 6 … Initiating circuit alarmNAC trouble / silence Supervisory troubleSystem trouble Auxiliary power output conditionsBattery power conditions AC power conditionsCPG #2561255 IRE L ARM 2500 Operating Manual Safety message to installers InstallationNfpa and UL installation requirements Installing the cabinet and optional bezel Requirements for Central Station Fire Alarm SystemsUsing the Calculation Table Table WiringZonal Digital Alarm Communicator Transmitter optional Zdact Battery size requirementsCurrent Requirements Motherboard Device Wiring Notification Appliance Circuits Connections DiagramCPG #2561255 IRE L ARM 2500 Operating Manual 2 B1 Temporal pattern Configuration and ProgrammingSelecting connected device options DIP switches 1 B1 Strobe deviceProgram configuration of the panel Order of characters Setup ZONES?Setup ZDACT? Zdact configurationAC Delay HR Number Keys Password settingsTesting the control panel MaintenanceAuto Reset feature One-man test Inspection and Test procedureTesting the Remote Annunciator Electrical Connections Appendix A. Optional AccessoriesKey Function Control When Active Remote Annunciator with Liquid Crystal Display 2500-RALCDFigure A-2. Zdact Mounting Zonal Digital Alarm Communicator Transmitter 2500-ZDACTTransient Protected Built in 5.1K END of Line Resistor Style Z Class a Module for NAC circuits CAMFigure A-5. MBM Master Box Module Model MBMMBM InstallationCPG #2561255 IRE L ARM 2500 Operating Manual ESL MAX. NO. of Detectors PER Zone is Appendix B. Smoke Detector CompatibilityContents Appendix C. NAC Compatibility Contents Options Model No Description Stock No Replacement Parts Model No Description Stock NoAppendix D. Ordering Information Base Components Model No Description Stock NoContents Appendix E. Quick Reference Operating Instructions FireLarm Contents