Hearth and Home Technologies COLBAY-FS-B Serial Number Barcode, Model Name Test Lab Report No

Page 2

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fireplaces. And yet we are old-fash- ioned when it comes to craftsmanship. Each appliance is

meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. From design, to fabrication, to shipping: Our guarantee of quality is more than a word, it’s Quadra- Fire tradition, and we proudly back this tradition with a Lim- ited Lifetime Warranty.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: ON BACK OF APPLIANCE

 

 

 

MODEL / MODÈLE:

 

SERIAL NO.

 

 

 

COLUMBIA BAY

 

002

 

 

800 West Jefferson Street

VENTED GAS FIREPLACE HEATER.

 

 

 

Report / Rapport

NOT FOR USE WITH SOLID FUEL

 

 

 

061-S-19b-5

Lake City, MN 55041

FOURNAISE AU GAZ AVEC VENTILATION

 

 

 

 

www.quadrafire.com

NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE

 

 

APPROVED FOR CANADA AND USA TO:

 

 

 

MINIMUM CLEARANCES TO COMBUSTIBLES

ESPACE MINIMUM AUX COMBUSTIBLES

Minimum clearances required from combustible construction for all appliance surfaces.

Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.

Serial Number Barcode

ANSI Z21.88a-2001 / CSA 2.33a-M01 Vented Gas Fireplace Heaters, and applicable

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:

ANSI Z21.88a-2001 / CSA 2.33a-M01 Fournaises au Gaz avec Ventilation, et les sections

sections of UL307b Gas Burning Heating Appliances for Manufactured Homes

applicable de UL 307b Appareils de Chauffage Au Gaz pour les Maisons Mobiles et les

and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances for use

Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for use at High Altitudes”.

at High Altitudes.” This appliance is manufactured for operation with Natural

Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour une conversion

Gas. For conversion to propane Manufacturer’s Part #842-4041 and instructions

au gaz propane les pièces du Manufacturier #842-4041 et ses instructions doivent être

must be used. This appliance may be installed in a bedroom or bedsitting room;

utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle de séjour; au

in Canada remote thermostat installation is required.

 

 

Canada, l’installation d’un thermostat à distance est exigée.

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE

Thermal Efficiency / Efficacité Thermique*

Blower Electrical Rating / Évaluation du Ventilateur Électrique:

 

 

 

84% NG (blower on / avec ventilateur allumé)

 

 

 

86% LP (blower on / avec ventilateur allumé)

115 V., 1.5 Amps, 60 Hz, 150 Watts

 

* With Maximum horizontal length. / Avec longueur horizontale maximum.

 

 

P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum) 65.42% NG / 65.96% LP

 

For use with Natural Gas

For use with Propane

 

Usage Au Gaz Naturel

Usage Au Gaz Propane

Top Vent: Input Rate on “HI” (BTU/Hr)

0-2000’

 

0-2000’

Puissance Évaluée à “HI” (BTU/Hr)

30,000

 

30,000

Input Rate on “LO” (BTU/Hr)

21,000

 

24,500

Puissance Évaluée à “LO” (BTU/Hr)

Maximum Output (BTU/Hr)**

25,250

 

25,800

Puissance Maximum (BTU/Hr)**

Main Burner Orifice

.1065 (36 DMS)

 

.0635 (52 DMS)

Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)

4.5”

 

11”

Pression Minimum de la Valve (pouces W.C.)

Maximum Inlet Pressure (Inches W.C.)

7.0”

 

14”

Pression Maximum de la Valve (pouces W.C.)

Manifold Pressure on “HI” (Inches W.C.)

3.5”

 

10”

Pression du Collecteur d’ Échappement à “HI”

**Max Venting, Blower On

 

 

 

 

(pouces W.C.)

 

 

 

 

** Ventilation Maximum, Ventilateur Allumé

I

 

B

C

 

 

H

A

 

D

 

 

F

E

E

Alcove height G- Hauteur De

l’Alcôve

A* A*

Model Name

Test Lab &

Report No.

This appliance equipped only for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes.

Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations sur ces changements.

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow the National Fuel Gas Code, ANSI Z223.1 or Canadian Installation Codes, CAN/CGA-B149. Install and use only in accordance with manufacturer’s installation and operating instructions. NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.)

Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez ANSI Z223.1/CAN 1-B149.

Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)

This appliance must be installed in accordance with the current Standard C N/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard,

Title 24 CFR, Part 3280, or when such standard is not applicable, NSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard.

Serie

WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions.

Installer l'appareil selon la norme CAN/CSA-Z240,

MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces

normes ne sont pas pertineutes, utilisez la norme ANSI/NCSBCS 225.1/NFPA 501A, Manufactured Home Installations Standard. AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant.

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions. Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant.

Keep burner and control compartment clean. ee installation and operating instructions accompanying this appliance. This vented gas fireplace heater is not for use with air filters. Due to high surface temperatures, keep children, clothing and furniture away.

Gardez le brûleur et le compartiment de contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent cet appareil. Cet appareil de chauffage au gaz n’est pas pour l’usage avec des filtres d’air. Du aux surfaces de températures élevées, gardez les enfants, les vêtements et les meubles à distance éloignée.

A.

Side of stove top to side wall

6 in. (152 mm)

A*.

Du coté du poêle au coté du mur

6-3/4 in. (171 mm)

In an Alcove

B.

Dans l’alcôve

2 in. (51 mm)

Rear of control box to back wall

C.

Le contrôle arrière au mur arrière

6 in. (152 mm)

Flue pipe to back wall

D.

Du tuyau de cheminée au mur arrière

14 in. (356 mm)

Flue pipe to side wall

E.

Du tuyau de cheminée au mur du coté

2 in. (51 mm)

Rear corner of stove top to side wall

F.

Du coin arrière du poêle au mur de coté

84 in. (2134 mm)

Min. Floor to ceiling height (std. room)

G.

Hauteur minimum du plancher au plafond (pièce standard)

19 in. (483 mm)

Top of stove to alcove ceiling

H.

Du dessus du poêle au plafond de l’alcôve

36 in. (914 mm)

Maximum alcove depth

I.

Profondeur maximum de l’alcôve

36 in. (914 mm)

Minimum alcove width

 

Largeur minimum de l’alcôve

 

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support

the stove without a tipping hazard.

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.

 

Date of Manufacture / Date du Manufacturier

 

DO NOT REMOVE THIS LABEL / NE PAS

 

 

 

2005 2006 2007 Jan Feb Mar Apr May Jun

Jul

Aug Sep

Oct Nov Dec

ENLEVER L’ÉTIQUETTE

 

Made in U.S.A. / Fait Aux États-Unis

 

 

 

 

 

 

 

 

 

 

250-5184

 

 

 

 

 

Manufactured Date

Page 2

Quadra-Fire • Columbia Bay • 250-5195 Rev.K

10/08

Image 2
Contents Do not Discard this Manual What to do if you smell gasCOLBAY-FS-B Do DiscardnotSerial Number Barcode Model Name Test Lab Report NoTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances Appliance Location and ClearancesSelecting Appliance Location 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsVertical Distance From Appliance to To the 90 Elbow How to Use the Vent GraphVenting Guidelines Horizontal Termination StepWallline Thimble Fold Strap Here Sheet Metal Screw Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Top Adapter Flex Pipe Sheet Metal Screws StepExisting Masonry Chimney Retro Connector Converting to LP Gas Gas InformationFuel Conversions Valve Regulator Replacement Gas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationThermopile GAS Pilot Ignitor Thermocouple Brick Installation Door Crown Installation Appliance SetupAccessories Remove Shipping MaterialsInstall NEW Brick SET Positioning the LogsGlass Door Replacement Mineral WoolBlower Installation BlackVertical Damper Adjustment Shutter AdjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions After Appliance is LitTroubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Service and Maintenance Log Appliance Dimension Diagram Reference MaterialsVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Part number list on followingAt Depot StockedDepot Pedestal ComponentsStocked Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Serial Number Date Purchased Date Installed Dealer Telephone Columbia Bay Direct Vent Gas Appliance