Symptom

Possible Cause

Corrective Action

3.

(Continued)

c. Defective valve.

Turn the valve knob to the ON position. Place the ON/OFF switch in the

 

 

 

ON position. Check the millivolt meter at the thermopile terminals. The

 

 

 

millivolt meter should read greater than 125mV. If the reading is accept-

 

 

 

able, and if the burner does not come on, replace the gas valve.

 

 

d. Plugged burner

Check the burner orifice for stoppage. Remove stoppage.

 

 

orifice.

 

 

 

e. Wall switch or

Follow the corrective action in Symptom and Possible Cause 1.a.

 

 

wires are defective.

Check the switch and wiring. Replace where defective.

4.

Frequent pilot outage

a. Pilot flame may

Clean and adjust the pilot flame for maximum flame impingement on

problem.

be too high or too

thermocouple. Follow lighting instructions carefully.

 

 

low, or blowing

 

 

 

(high), causing safety

 

 

 

pilot to drop out.

 

5.

The pilot and main

a. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while

b. Inner vent pipe

Check for proper vent connection at flue collar and all vent joints.

in operation.

leaking exhaust

 

 

 

gases back into the

 

 

 

system.

 

 

 

c. Horizontal vent

The horizontal vent cap should slope down only enough to prevent any

 

 

improperly pitched.

water from entering the appliance.

 

 

d. Bad thermopile or

Replace if necessary.

 

 

thermocouple.

 

 

 

e. Improper vent cap

Check for proper installation and freedom from debris or blockage.

 

 

installation.

 

6.

Glass soots.

a. Flame impinge-

Adjust the log set so that the flame does not excessively impinge on it.

 

 

ment.

Check that logs are placed according to installation instructions.

 

 

b. Improper shutter

Adjust the air shutter at the base of the burner.

 

 

setting.

 

 

 

c. Debris around

Inspect the opening at the base of the burner. NO MATERIAL SHOULD

 

 

opening at base of

BE PLACED IN THIS OPENING.

 

 

burner.

 

7.

Flame burns blue

a. Insufficient

Ensure that the vent cap is installed properly and free of debris. Ensure

and lifts off burner.

oxygen being sup-

that the vent system joints are tight and have no leaks.

 

 

plied.

Ensure that no debris has been placed at the base of, or in the area of

 

 

 

 

 

 

the air holes in the center of the base pan beneath the burner.

 

 

 

Ensure that the glass is tightened properly on the appliance, particu-

 

 

 

larly on top corners.

10/08

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

Page 37

Image 37
Contents COLBAY-FS-B What to do if you smell gasDo not Discard this Manual Do DiscardnotModel Name Test Lab Report No Serial Number BarcodeTable of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Getting Started Design & Installation ConsiderationsInspect Appliance & Components Tools and Supplies NeededSelecting Appliance Location Appliance Location and ClearancesClearances Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsVenting Guidelines How to Use the Vent GraphVertical Distance From Appliance to To the 90 Elbow Step Horizontal TerminationWallline Thimble Fold Strap Here Sheet Metal Screw Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Top Adapter Flex Pipe Sheet Metal Screws Step Class a Metal ChimneyExisting Masonry Chimney Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Electrical InformationThermopile GAS Pilot Ignitor Thermocouple Accessories Appliance SetupBrick Installation Door Crown Installation Remove Shipping MaterialsPositioning the Logs Install NEW Brick SETMineral Wool Glass Door ReplacementBlack Blower InstallationShutter Adjustment Vertical Damper AdjustmentBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsSymptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceMaintenance Tasks Inspect Service and Maintenance Log Reference Materials Appliance Dimension DiagramSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListPart number list on following Log Set AssemblyStocked At DepotStocked Pedestal ComponentsDepot Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Columbia Bay Direct Vent Gas Appliance Serial Number Date Purchased Date Installed Dealer Telephone