Figure 8.9 Place right and left front logs on burner in the grooves provided on the burner surface.

that gas can contact them on all sides. Avoid stacking the embers on top of each other.

NOTE: Do not block gas ports.

G. Glass Door Replacement

Remove the grille: Slide the grille out of the slots in the exist- ing door.

Remove the existing door from the appliance.

Remove the crown from the existing door by removing four screws on the back side of the door assembly. Pull crown off door face.

Install replacement door with glass onto appliance.

Reinstall the crown.

Reinstall the grille onto the new door assembly.

Figure 8.10 Place twig over the locator pin on the rear log, gently laying the log across the two front logs. To complete your log set application reinstall the front of the unit.

F. Mineral Wool

WARNING

Explosion Risk.

Follow ember placement instructions in manual.

Do NOT place embers directly over burner ports.

Replace ember material annually.

Improperly placed embers interferes with proper burner operation.

CAUTION

Handle glass assembly with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass assembly as a complete assembly.

Figure 8.11 Place individual pieces of embers in front of and around the gas log where they can be seen. Space them so

Page 30

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

10/08

Image 30
Contents Do not Discard this Manual What to do if you smell gasCOLBAY-FS-B Do DiscardnotSerial Number Barcode Model Name Test Lab Report NoTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance to To the 90 Elbow Horizontal Termination StepWallline Thimble Fold Strap Here Sheet Metal Screw Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Top Adapter Flex Pipe Sheet Metal Screws StepExisting Masonry Chimney Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Gas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical Information Thermopile GAS Pilot Ignitor Thermocouple Brick Installation Door Crown Installation Appliance SetupAccessories Remove Shipping MaterialsInstall NEW Brick SET Positioning the LogsGlass Door Replacement Mineral WoolBlower Installation BlackVertical Damper Adjustment Shutter AdjustmentOperating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions After Appliance is LitTroubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Service and Maintenance Log Appliance Dimension Diagram Reference MaterialsVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Part number list on followingAt Depot StockedDepot Pedestal ComponentsStocked Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Serial Number Date Purchased Date Installed Dealer Telephone Columbia Bay Direct Vent Gas Appliance