Hearth and Home Technologies COLBAY-FS-B owner manual Retro Connector

Page 21

WARNING

Fire Risk.

Explosion Risk.

Do not let the flex liner sag below the level at which it will connect to the appliance or connector. This could allow hot gas to become trapped and potentially become a fire hazard. The flex liner path should always be sloped up toward the termination cap.

Step 7.

If additional lengths of flex liner are needed to span the chimney height, use a flex coupler to connect the pieces of flex liner together. Connect the flex to the coupler by using four sheet metal screws for each side (Figure 5.28).

FLEX LINER

FLEX COUPLER

SHEET METAL

SCREWS

Figure 5.28

Step 8.

Secure the top adapter to the flashing. Use three sheet metal screws through the side of the top adapter into the flange on the flashing (Figure 5.29). Twist lock the high wind termination cap on to the top adapter.

HIGH WIND

TERMINATION CAP

TOP ADAPTOR

Step 9.

Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector (Figure 5.30). Mount the retro connector to the masonry wall using masonry bolts. Redrill larger holes on connector as needed. Be careful to ensure that the connector is centered in the opening and the mounting holes line up with the masonry wall.

6 in. (152mm)

DIAMETER OPENING IN MASONRY WALL

RETRO CONNECTOR

 

THREE MASONRY BOLTS

Figure 5.30

(NOT INCLUDED)

 

Step 10.

Slide the wall thimble cover over retro connector and secure with masonry bolts (Figure 5.31). If you have a framed wall in front of the masonry, use wood screws to mount wall thimble cover to framed wall, over retro connector and 10 in. (254mm) square framed opening (Figure 5.26, page 20). If needed, add a section of direct vent pipe to the retro connector in order to extend through the opening in the wall thimble cover.

RETRO CONNECTOR

Figure 5.29

THREE SHEET

METAL SCREWS

FLASHING

WALL THIMBLE COVER

FOUR MASONRY BOLTS (NOT INCLUDED)

Figure 5.31

Step 11.

The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

10/08

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

Page 21

Image 21
Contents COLBAY-FS-B What to do if you smell gasDo not Discard this Manual Do DiscardnotModel Name Test Lab Report No Serial Number BarcodeTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Getting Started Design & Installation ConsiderationsInspect Appliance & Components Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance to To the 90 Elbow Step Horizontal TerminationWallline Thimble Fold Strap Here Sheet Metal Screw Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Top Adapter Flex Pipe Sheet Metal Screws Step Class a Metal ChimneyExisting Masonry Chimney Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Electrical InformationThermopile GAS Pilot Ignitor Thermocouple Accessories Appliance SetupBrick Installation Door Crown Installation Remove Shipping MaterialsPositioning the Logs Install NEW Brick SETMineral Wool Glass Door ReplacementBlack Blower InstallationShutter Adjustment Vertical Damper AdjustmentOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsSymptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceMaintenance Tasks Inspect Service and Maintenance Log Reference Materials Appliance Dimension DiagramSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListPart number list on following Log Set AssemblyStocked At DepotStocked Pedestal ComponentsDepot Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Columbia Bay Direct Vent Gas Appliance Serial Number Date Purchased Date Installed Dealer Telephone