IGNITOR

Red 28 in.

(711MM)

ON/OFF

SWITCH

Red 28 in.

(711MM)

Figure 7.1

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

THERMOPILE

GAS PILOT IGNITOR

THERMOCOUPLE

TPTH

 

A

E

 

 

 

TP

 

 

 

 

HI

O

 

TH

 

L

 

 

N

O

 

 

O

F

 

 

 

F

 

 

 

T

 

 

 

OLIP

 

P

 

 

 

TOLI

 

 

VALVE

CAUTION

Shock hazard.

Replace damaged wire with type 105O C rated wire.

Wire must have high temperature insulation.

10/08

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

Page 27

Image 27
Contents Do Discardnot What to do if you smell gasCOLBAY-FS-B Do not Discard this ManualModel Name Test Lab Report No Serial Number BarcodeTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools and Supplies Needed Design & Installation ConsiderationsGetting Started Inspect Appliance & ComponentsAppliance Location and Clearances Selecting Appliance LocationClearances Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance to To the 90 Elbow Step Horizontal TerminationWallline Thimble Fold Strap Here Sheet Metal Screw Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Top Adapter Flex Pipe Sheet Metal Screws Step Class a Metal ChimneyExisting Masonry Chimney Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Pressure Gas Pressures Gas ConnectionCheck for GAS Leaks Electrical Information Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringThermopile GAS Pilot Ignitor Thermocouple Remove Shipping Materials Appliance SetupAccessories Brick Installation Door Crown InstallationPositioning the Logs Install NEW Brick SETMineral Wool Glass Door ReplacementBlack Blower InstallationShutter Adjustment Vertical Damper AdjustmentOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsSymptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceMaintenance Tasks Inspect Service and Maintenance Log Reference Materials Appliance Dimension DiagramSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListPart number list on following Log Set AssemblyStocked At DepotValve Components Pedestal ComponentsStocked DepotCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Columbia Bay Direct Vent Gas Appliance Serial Number Date Purchased Date Installed Dealer Telephone