Page 6

2 Getting Started

A. Design & Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

When planning an installation, it is necessary to determine the following information before installing:

Where the appliance is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Whether optional accessories - devices such as a blower, thermostat or remote control - are desired.

C. Inspect Appliance & Components

WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

• Do NOT install substitute components.

Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

Remove cast door and glass door, and set aside on pro- tective surface.

Remove log set and component pack from firebox.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING

Keep appliance dry.

Mold or rust may cause odors.

Water may damage controls.

B.Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available. Note: Not all

tools will apply to every installation.

Reciprocating saw

Variable Speed Drill/Driver

Pliers

Wrench Set

Hammer

Framing Square

Phillips Screwdriver

Framing Material

Flat Blade Screwdriver

Hi temp caulking material

Plumb Line

Voltmeter

Level

Gloves

Manometer

Safety Glasses

Tape Measure

Non-corrosive Leak Check Solution

 

or combustible gas detector

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

Page 6

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

10/08

Image 6
Contents Do not Discard this Manual What to do if you smell gasCOLBAY-FS-B Do DiscardnotSerial Number Barcode Model Name Test Lab Report NoTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance to To the 90 Elbow Horizontal Termination StepWallline Thimble Fold Strap Here Sheet Metal Screw Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Top Adapter Flex Pipe Sheet Metal Screws StepExisting Masonry Chimney Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Gas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationThermopile GAS Pilot Ignitor Thermocouple Brick Installation Door Crown Installation Appliance SetupAccessories Remove Shipping MaterialsInstall NEW Brick SET Positioning the LogsGlass Door Replacement Mineral WoolBlower Installation BlackVertical Damper Adjustment Shutter AdjustmentOperating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions After Appliance is LitTroubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Service and Maintenance Log Appliance Dimension Diagram Reference MaterialsVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Part number list on followingAt Depot StockedDepot Pedestal ComponentsStocked Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Serial Number Date Purchased Date Installed Dealer Telephone Columbia Bay Direct Vent Gas Appliance