Hearth and Home Technologies COLBAY-FS-B Vent Components Diagram, SLP Series Vent Components

Page 42

B. Vent Components Diagram

6-9/16 in.

167 mm

9-7/16 in.

240 mm

6-5/8 in. 168 mm

SLP45

6-1/2 in. 165 mm

6-9/16 in.

 

167 mm

9-1/4 in.

6 in.

235 mm

152 mm

6-5/8 in. 168 mm

9-3/4 in. 248 mm

SLP90

6-5/8 in.

168 mm

6-5/8 in.

168 mm

13-1/4 in. 337 mm

7-1/4 in.

184 mm

6-9/16 in.

167 mm

SLP12A

SLP6A

6-5/8 in.

168 mm

6-5/8 in.

168 mm

25-1/4 in.

641 mm

13-1/4 in.

337 mm

6-9/16 in.

 

 

 

 

 

6-9/16 in.

 

 

 

 

 

167 mm

 

 

 

 

 

 

 

 

 

 

167 mm

 

 

 

 

 

 

6-5/8 in.

168 mm

5-1/4 in.

133 mm

6-9/16 in.

167 mm

SLP4

6-5/8 in.

168 mm

37-1/4 in.

946 mm

6-9/16 in.

167 mm

6-5/8 in.

168 mm

7-1/4 in.

184 mm

SLP6

6-5/8 in.

168 mm

49-1/4 in.

1251 mm

6-9/16 in.

167 mm

SLP12

SLP24

SLP36

SLP48

Note: Pipes overlap 1-3/8 inches (34.93 mm) at each joint.

Figure 12.2 SLP Series Vent Components

Page 42

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

10/08

Image 42
Contents Do not Discard this Manual What to do if you smell gasCOLBAY-FS-B Do DiscardnotSerial Number Barcode Model Name Test Lab Report NoTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance to To the 90 Elbow Horizontal Termination StepWallline Thimble Fold Strap Here Sheet Metal Screw Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Top Adapter Flex Pipe Sheet Metal Screws StepExisting Masonry Chimney Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Valve Regulator Replacement Gas Pressures Gas Connection PressureCheck for GAS Leaks Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationThermopile GAS Pilot Ignitor Thermocouple Brick Installation Door Crown Installation Appliance SetupAccessories Remove Shipping MaterialsInstall NEW Brick SET Positioning the LogsGlass Door Replacement Mineral WoolBlower Installation BlackVertical Damper Adjustment Shutter AdjustmentOperating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions After Appliance is LitTroubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Service and Maintenance Log Appliance Dimension Diagram Reference MaterialsVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Part number list on followingAt Depot StockedDepot Pedestal ComponentsStocked Valve ComponentsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Serial Number Date Purchased Date Installed Dealer Telephone Columbia Bay Direct Vent Gas Appliance