Hearth and Home Technologies Heat & Glo, 6000TRSI-AUC manual LOG Placement Instructions, Tabs

Page 22

G. LOG PLACEMENT INSTRUCTIONS

Log Assembly: LOG-6TRSI-AUC

 

 

 

 

 

 

 

 

1

3

TABS

2

5 4

CAUTION: Logs are fragile! Carefully remove the logs from the packaging.

1

1

LOG #1 (SRV2049-700):Locate log #1 by placing log notches on the second and fifth grate bars and push log against rear log locators.

2

2

LOG #2 (SRV2049-701):Locate log #2 on grate with notches. Slide back against tabs.

22

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

Image 22
Contents Installation and Operation Instructions Model 6000TRSI-AUCHeat & Glo Quality Systems Table of Contents Installation Instructions 476 686 31-5/8 803 174 126.9Top Flue Rear FlueClearance Requirements Framing the Heater Clearances n mm Flue System Approvals and Installations 10.97m13.1 331mm 24 610mm ElbowsFlueing with One 90 Elbow +H 1 FT + H 1 FT 13 Flueing with three 90 elbows Flueing with Three 3 90 Elbows + H 1 FTFlueing Out the Rear Flue Flueing Out the Top FlueAssembling Flue Components Install Support Brackets Flue Termination Connecting the GAS Supply Must be Positioned SO That the Arrow is Pointing UPIgnition System Wiring Shock RiskBlower Fan Mantel Clearances Clearance to a mantelpiece is 12 inches 305mm. See FigureLOG Placement Instructions TabsHeat & Glo 6000TRSI-AUC 2078-900 Rev. G 12/06 Installer Testing Operating InstructionsOperating Cautions For Your Safety Read Before Lighting Instructions Safety & Lighting InformationPower Outage FAN OperationServicing and Maintenance Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemAdjust the air shutter at the base of the burner Log set assembly 6000TRSI-AUC6000TRSI-AUC GLA-6TRXILimited 10 Year Warranty Heat & GLO, a brand of Hearth & Home Technologies IncMelbourne