Hearth and Home Technologies Heat & Glo, 6000TRSI-AUC manual Inspect Maintenance Tasks

Page 30

E.MAINTENANCE TASKS

Inspect

 

Maintenance Tasks

Doors

1. Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

 

2.

Verify no obstructions to airflow .

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to

 

heat.

 

3. Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment

 

components are intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot

 

be removed.

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as

 

necessary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as

 

necessary.

 

2.

Replace gas fireplace if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

 

necessary.

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or

 

obstruct lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

9.

Inspect thermocouple for soot, corrosion and deterioration. Clean with emery cloth or

 

replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote controls

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

30

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

Image 30
Contents Installation and Operation Instructions Model 6000TRSI-AUCHeat & Glo Quality Systems Table of Contents Installation Instructions 476 686 31-5/8 803 174 126.9Rear Flue Top FlueClearance Requirements Framing the Heater Clearances n mm Flue System Approvals and Installations 10.97m13.1 331mm 24 610mm ElbowsFlueing with One 90 Elbow +H 1 FT + H 1 FT 13 Flueing with three 90 elbows Flueing with Three 3 90 Elbows + H 1 FTFlueing Out the Rear Flue Flueing Out the Top FlueAssembling Flue Components Install Support Brackets Flue Termination Connecting the GAS Supply Must be Positioned SO That the Arrow is Pointing UPIgnition System Wiring Shock RiskBlower Fan Mantel Clearances Clearance to a mantelpiece is 12 inches 305mm. See FigureLOG Placement Instructions TabsHeat & Glo 6000TRSI-AUC 2078-900 Rev. G 12/06 Installer Testing Operating InstructionsOperating Cautions For Your Safety Read Before Lighting Instructions Safety & Lighting InformationPower Outage FAN OperationServicing and Maintenance Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemAdjust the air shutter at the base of the burner Log set assembly 6000TRSI-AUC6000TRSI-AUC GLA-6TRXILimited 10 Year Warranty Heat & GLO, a brand of Hearth & Home Technologies IncMelbourne