Hearth and Home Technologies Heat & Glo manual For Your Safety Read Before Lighting Instructions

Page 26

A.SAFETY & LIGHTING INFORMATION

Follow SAFETY INFORMATION and LIGHTING IN- STRUCTIONS to light the appliance.

By design, the flame pattern will not be identical from unit to unit. Additionally, flame pattern may vary depend- ing on installation type and weather conditions.

NOTE: THE TIPS OF THE FLAMES SHOULD NEVER HIT THE TOP OF THE FIREBOX.

These gas models have remote control valve which al- low you to increase or decrease the height of the main burner flames. Push thebutton to increase the flame height and the button to decrease the flame height.

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS

1. This gas fireplace is equipped with an

ignition device which automatically

A. This appliance is equipped with an electronic ignition system which automatically lights the burner. Do not try to light the burner by hand.

B. BEFORE LIGHTING, smell all

around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. Do not use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

lights the burner. Do not try to light the

burner by hand.

GAS

VALVE

2. Wait five (5) minutes to clear out any

gas. Then smell for gas, including near

the floor. If you smell gas, STOP! Fol-

low "B" in the Safety Information located

on the left side of this label. If you don't

smell gas, go to next step.

WARNING:

DO NOT CONNECT 220/240

VAC TO THE CONTROL VALVE.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam- age. Refer to the owner's informa- tion manual provided with this ap- pliance.

This appliance needs fresh air for safe operation and must be in- stalled so there are provisions for adequate combustion and ventila- tion air.

If not installed, operated, and main- tained in accordance with the manufacturer's instructions, this product could expose you to sub- stances in fuel or fuel combustion.

Keep burner and control compart- ment clean. See installation and operating instructions accompany- ing appliance.

CAUTION:

Hot while in operation. Do not touch. Keep children, clothing, fur- niture, gasoline and other liquids having flammable vapors away.

Do not operate the appliance with panel(s) removed, cracked or bro- ken. Replacement of the panel(s) should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural, propane and butane gases.

3. To light the burner, simultaneously

press the star and up arrow but- tons on the remote control until a short acoustic signal confirms the start se- quence has begun.

4.If the gas fireplace will not operate, check the batteries then follow the instructions “To Turn Off Gas to Ap- pliance” and call your service techni- cian or gas supplier.

TO TURN OFF GAS TOAPPLIANCE

1.Push the "OFF" button on remote.

2.Remove power from receiver.

26

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

Image 26
Contents Installation and Operation Instructions Model 6000TRSI-AUCHeat & Glo Quality Systems Table of Contents Installation Instructions 476 686 31-5/8 803 174 126.9Clearance Requirements Rear FlueTop Flue Framing the Heater Clearances n mm Flue System Approvals and Installations 10.97m13.1 331mm 24 610mm ElbowsFlueing with One 90 Elbow +H 1 FT + H 1 FT 13 Flueing with three 90 elbows Flueing with Three 3 90 Elbows + H 1 FTFlueing Out the Rear Flue Flueing Out the Top FlueAssembling Flue Components Install Support Brackets Flue Termination Connecting the GAS Supply Must be Positioned SO That the Arrow is Pointing UPIgnition System Wiring Shock RiskBlower Fan Mantel Clearances Clearance to a mantelpiece is 12 inches 305mm. See FigureLOG Placement Instructions TabsHeat & Glo 6000TRSI-AUC 2078-900 Rev. G 12/06 Installer Testing Operating InstructionsOperating Cautions For Your Safety Read Before Lighting Instructions Safety & Lighting InformationPower Outage FAN OperationServicing and Maintenance Adjustments and Replacement Parts Removal of Components for ServiceParts Replacement Removal of Covers for ServicingMaintenance Tasks Inspect Maintenance TasksTroubleshooting Electronic Ignition SystemAdjust the air shutter at the base of the burner Log set assembly 6000TRSI-AUC6000TRSI-AUC GLA-6TRXILimited 10 Year Warranty Heat & GLO, a brand of Hearth & Home Technologies IncMelbourne