B. POWER OUTAGE

In the event of a power interruption during opera- tion, either push the OFF button on the remote control or open access door and push the switch to OFF (as shown in Figure 39) to shut off manually. The switch must be returned to the ON position prior to operation once power is restored.

SWITCH IS SHOWN

IN "ON" POSITION

Figure 2.2

C. FAN OPERATION

The accessory fan is wired in series with a speed con- trol switch and a temperature sensor switch. Set the speed control to an "ON" position and light the heater. The temperature sensor switch will automatically start the fan when the switch warms up—and stop the fan when it cools down. You can manually stop the fan by turning the speed control switch to "OFF". See Figure 1.30 for fan wiring diagram.

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

27

Image 27
Contents Model 6000TRSI-AUC Installation and Operation InstructionsHeat & Glo Quality Systems Table of Contents 476 686 31-5/8 803 174 126.9 Installation InstructionsRear Flue Top FlueClearance Requirements Framing the Heater Clearances n mm 10.97m Flue System Approvals and InstallationsElbows 13.1 331mm 24 610mmFlueing with One 90 Elbow +H 1 FT + H 1 FT 13 Flueing with three 90 elbows + H 1 FT Flueing with Three 3 90 ElbowsFlueing Out the Top Flue Flueing Out the Rear FlueAssembling Flue Components Install Support Brackets Flue Termination Must be Positioned SO That the Arrow is Pointing UP Connecting the GAS SupplyShock Risk Ignition System WiringBlower Fan Clearance to a mantelpiece is 12 inches 305mm. See Figure Mantel ClearancesTabs LOG Placement InstructionsHeat & Glo 6000TRSI-AUC 2078-900 Rev. G 12/06 Operating Instructions Installer TestingOperating Cautions Safety & Lighting Information For Your Safety Read Before Lighting InstructionsFAN Operation Power OutageServicing and Maintenance Removal of Covers for Servicing Removal of Components for ServiceParts Replacement Adjustments and Replacement PartsInspect Maintenance Tasks Maintenance TasksElectronic Ignition System TroubleshootingAdjust the air shutter at the base of the burner 6000TRSI-AUC Log set assemblyGLA-6TRXI 6000TRSI-AUCHeat & GLO, a brand of Hearth & Home Technologies Inc Limited 10 Year WarrantyMelbourne