Electronic Ignition System - (continued)
Symptom | Possible Causes | Corrective Actions |
10. Glass soots. | a. Flame impingement on | Adjust the log set so that the flame does not impinge on it. |
| logs. |
|
|
|
|
| b. Improper venturi setting. | Adjust the air shutter at the base of the burner. |
|
|
|
| c. Debris around venturi. | Inspect the opening at the base of the burner. It is imperative that NO |
|
| material be placed in this opening. |
|
|
|
11. Flame burns blue | a. Insufficient oxygen | 1. Check to make sure flue cap is installed properly and free of debris. |
and lifts off burner. | being supplied. | Make sure that flue system points are tight and have no leaks. |
|
| 2. Check to make sure that no material has been placed in the opening at |
|
| the burner base or in the area of the air holes in the center of the base |
|
| pan beneath the burne. |
|
| 3. Be sure glass is tighened properly on unit, particularly on top corners. |
32 | Heat & Glo • |