Wayne RPPCAP50, 331301-001 operating instructions Troubleshooting Chart RPP50

Page 4

Operating Instructions

Troubleshooting Chart - RPP50

Symptom

Possible Cause(s)

Corrective Action

 

 

 

Pump will not start or run

1. Water level too low

1. Pump switch will not turn on unless water covers top of

 

pump

2. Blown fuse or tripped circuit

2. If blown, replace with proper sized fuse or reset breaker

breaker

 

3. Low line voltage

3. If voltage is under recommended minimum, check wiring

 

size from the main switch on property. If OK, contact power

 

company.

4. Defective motor

4. Return for service or replace motor

5. Defective float switch

5. Replace float switch

6. Impeller (pump filled with

6. If impeller will not turn, remove housing and remove debris

debris)

 

7. Tangled switch

7. Arrange switch so the switch moves freely. Reposition pump

 

if necessary

8. Insufficient liquid level

8. Make sure liquid level is at least 13" from the basin floor

Pump starts and stops too often

1. Backflow of water from piping

1. Install check valve

2. Faulty float switch

2. Replace float switch

3. Check valve not installed or

3. Remove and examine check valve for proper installation

leaking

and free operation

4. Discharge head is less than

4. Recheck all sizing calculations to determine proper pump

manufacturer’s minimum

size

Pump shuts off and turns on independently of switch (trips thermal overload protection)

1.Excessive water temperature

2.Defective switch or entangled switch is causing pump to run dry

1.Pump should not be used for water above 120°

2.Replace or reposition pump

Pump may start unexpectedly. Disconnect power supply before

servicing

3. Low line voltage

3. If voltage is under recommended minimum, check wiring

 

size from the main switch on property. If OK, contact power

 

company

 

 

Pump operates noisily or vibrates excessively

1.Worn bearings

2.Debris in impeller cavity or broken

3.Piping attachments to building structure too rigid or too loose

1.Replace pump

2.Remove housing, clean impeller and/or replace broken impeller

3.Replace portion of discharge pipe with flexible connector

Pump will not shut off 1. Defective float switch

2.Float switch movement restricted

3.Restricted discharge (obstruction in piping)

4.Excessive inflow or pump not properly sized for application

1.Replace float switch

2.Reposition pump or clean basin as required to provide adequate clearance for float

3.Remove pump and clean pump & piping

4.Recheck all sizing calculation to determine proper pump size

Pump operates but delivers little or no water

1.Low line voltage

2.Debris caught in impeller or discharge

3.Worn or defective pump parts or plugged impeller

4.Pump not properly sized for application

5.Check valve stuck closed or installed backwards

6.Shut off valve closed

1.If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company

2.Remove, clean and check for tightness

3.Replace entire pump. Clean parts if required

4.Recheck all sizing calculations to determine proper pump size

5.Remove and examine check valve for proper installation and free operation

6.Open valve

www.waynepumps.com

4

Image 4
Contents General Safety Information Safety GuidelinesDescription Installation Causing personal injury and/or property damageOperating Instructions Pump motor isMaintenance Basin Switch Genius surfaceCheck valve 45o Vent Gasket Make certainTroubleshooting Chart RPP50 Troubleshooting Chart RPPCAP50 Limited Warranty Attach Your Receipt HereDirectives de Sécurité Généralités sur la SécuritéSpécifications FabricationInstructions d’Utilisation Généralités sur la Sécurité SuiteCette pompe Une vanne devrait être installée dans Pompe puisse être enlevée sans tropClapet 45o Évent Joint d’étanchéité Arrivée Espace min Fileter le tuyau de décharge ou leEntretien Installation SuiteAvant d’enlever Guide de Dépannage RPP50 Si correcte, contacter la compagnie de service publiqueTaille des fils de l’interrupteur général de la propriété Guide de Dépannage- RPPCAP50 La pompe peut se démarrerSubitement. Débrancher la Source de puissance avant de procéder à l’entretienGarantie Limitée Descripción Medidas de SeguridadEspecificaciones Materiales de fabricaciónInformaciones Generales de Seguridad Continuación Informaciones Generales DE SeguridadInstalación De Seguridad ContinuaciónMantenimiento Instalación ContinuaciónLimpie bien el orificio de entrada de la bomba y la voluta Esta bombaDiagnóstico de Averías RPP50 Térmica se activaAl edificio son muy rígidas o están Muy flojasDiagnóstico de Averías RPPCAP50 Garantía Limitada Anexe SU Recibo Aqui