Constant green light on in dirt sensor.
No green or red dirt
sensor lights.
Performance Indicator
activates.
Vacuum cleaner picks up moveable rugs
Red light on
PowerMate.
I. Dirt passage is clogged. 2. Lenses are dirty.
I. No power to sensor board.
I. Full or dogged dust bag.
2.Dirty filters.
3.Blocked airflow passage.
4.Certain attachment tools.
I. Wrong pile height setting. 2. Suction too strong.
I. Tripped overload protector in PowerMate.
I.Check for clogs in air passages.
2. Clean lenses.
Take to your nearest Sears Service Center.
I.Change bag.
2. Change filters.
3. Clear blockage from airflow passage.
4.This is normal. Light should go off when tool is removed.
I.Adjust setting.
2. Select lower Power Level.
I.Remove any items that may be caught or jammed, then reset. If vacuum cleaner starts and stops again, clean agitator and end caps, then reset.
Cord | won't rewind. | I. | Dirty power cord. | I. | Clean the power | cord. |
|
| 2. | Cord jammed. | 2. | Pull out cord and | rewind. |
Vacuum cleaner leaves | I. | Wrong vacuuming pattern. | I. | See VACUUMING | TIPS. | |
marks | on carpet. |
|
|
|
|
|
Vacuum Cleaner Help Line: 1-877-531-7321
(U.S.A. and Canada)
- 24 -