Hearth and Home Technologies 810-02901 (MBK), CASTINS-CSB Baffle & Brick Set Removal, 35.1

Page 34

R

Castile Pellet Insert

G.Baffle & Brick Set Removal

1.Follow proper shutdown procedures on Page 28.

The top baffle has a hook on the bottom left side that rests on the top lip of the cast brick. There is a tab on the bottom right side that hooks into the side bracket. Remove the top baffle by first pulling the baffle forward until back edge drops down. Then slide baffle back until the front edge clears the shelf that it had been resting on.

Figure 34.1.

3.The top baffle must be removed before you can remove the right and left brick. Remove the right brick by hold- ing top lip of brick and lifting up, then push outside edge back. Slide brick to the right until it is flush with the firebox. Rotate the inside edge of the brick forward and remove brick. Repeat for left brick. Figure 34.2.

Hook on

left sideTab on right side

Figure 34.1

Remove Right

& Left Brick

Figure 34.2

Right Brick

Removed

Re-installing Baffle & Brick Set

1.Place right brick in behind the right bracket, and then slide to the left so the tabs are behind the center brick.

Figure 34.4

2.The brick will be flush against the back wall and notches exposed in the side bracket. Figure 34.5.

3.Lift slightly and pull the right edge of the brick forward until it stops and then drops down into both top and bottom notches of right bracket and locks into place. Figures

35.1and 35.2.

4.Repeat for left brick.

5.Insert baffle into top front inside the firebox and pull for- ward. Then raise up the bottom end and insert baffle tab into slot on the top of the right bracket to lock into place. Figure 35.3. Place the left side hook at the bottom of the baffle over the top edge of brick for stability. Figure

6.The baffle does not completely cover the top of the fire- box. There is an opening on the left as shown in Figure

Tabs

Figure 34.4

Brick is flush against back wall

Notches exposed

Figure 34.5

Vacuum

Exhaust Area

Figure 34.3

Page 34

250-7251F

September 1, 2008

Image 34
Contents Castile Pellet Insert 810-02901 MBK 810-03201 PMHCastile Pellet Insert Location Inside hopper on the topTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Glass SpecificationsGetting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationCastile Pellet Insert Tools And Supplies Needed Inspect Appliance & Components and Pre-Use Check List3Dimensions and Clearances Appliance DimensionsShown Optional Outside Air Castile Pellet Insert Clearance To Combustibles, UL and ULC0mm Clearance To Exposed Section And Face Trim Inches MillimetersMinimum Opening for Masonry and Zero Clearance Fireplaces Castile Pellet Insert Masonry and Zero Clearance FireplacesFloor Protection Location Inches MillimetersStarter hole Mark area of floor to cut Chimney and Exhaust Connection 4Vent InformationVenting Termination Requirements Castile Pellet Insert Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculation 5Venting Systems Castile Pellet Insert Full Reline With Outside Air Mobile Home Installation 6Mobile Home7Appliance Set-Up Top Vent InstallationRear Vent Installation Reversible Top or Rear Flue Adapter Leveling SystemAssembled View ItemDescriptionKit Includes See Base Plate Only InstallationCastile Pellet Insert Zero Clearance Trim Support Cont’d Piece. FigurePanel Set And Cast Trim Set Panel & Trim Set, EconoFour Piece Log Set Installation Top Log InstallationCastile Pellet Insert Thermostat Installation Fuel Size And Material Operating InstructionsGeneral Operating Information Castile Pellet Insert Before Your First Fire Feed Rate AdjustmentFire Characteristics Starting Your First FireFrequently Asked Questions Castile Pellet Insert Iginition CyclesSymptom TroubleshootingPossible Cause Corrective Action Page Symptom Possible Cause Corrective Action 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartCleaning or Inspection Frequency Daily Weekly Monthly YearlyAsh Removal from Firebox Remove Cast Sides for Cleaning & MaintenanceCleaning Firepot with Cleaning Rod & Firepot Scraper See Disposal of AshesCleaning Beneath Heat Exchanger Cleaning Heat Exchanger Chambers & Drop TubeCleaning the Exhaust Path Cleaning the Glass Cleaning the HopperCleaning Convection Blower Requires No Lubrication Cleaning Exhaust Blower Requires No LubricationDoor Gasket Inspection High Ash Fuel Content MaintenancePreparing Firebox for Non-Burn Season Frequency Yearly Igniter Replacement Baffle & Brick Set Removal 35.1Re-installing Baffle & Brick Set Cont’d Component Function Snap Disc #1 Convection Blower 110F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Fuel Delivery Interrupt 250FCleaning Rods & Heat Exchanger Tubes Castile Pellet Insert Component LocationsCastile Pellet Insert Exploded Views Glass Size 11-5/8 wide x 17-1/4 highDescription Castile Pellet Insert Service Parts and Accessories Item # Part Description, Alphabetical Order Part NumberItem No Appliance Item No Accessories, Alphabetical OrderItem # Part Description, Alphabetical Order Castile Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Homeowner’s Notes Castile Pellet Insert Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Castile Pellet Insert Telephone

CASTINS-CWL, CASTINS-CSB, 810-03201 (PMH), 810-02901 (MBK) specifications

Hearth and Home Technologies has made a significant mark in the hearth and home industry with a variety of innovative products, including models like the 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL. These models reflect state-of-the-art design and engineering, ensuring comfort and efficiency in residential heating solutions.

The 810-02901 (MBK) model is designed primarily for modular design, allowing for easy installation and integration into various home architectures. This model features advanced combustion technology that maximizes fuel efficiency while minimizing emissions. It is equipped with an innovative air control system that provides users with precise control over flame height and heat output, enhancing the overall user experience. With features such as a large viewing area, the MBK model provides an attractive look while ensuring optimum safety.

The 810-03201 (PMH) model offers versatile heating options and an elegant design that fits seamlessly into modern interiors. This model is notable for its user-friendly interface, which enables users to control settings with ease. It also has a remarkable heat distribution system, allowing warmth to spread evenly throughout the space, reducing cold spots and enhancing comfort. Additionally, the PMH model is built with durable materials that withstand the test of time, making it a long-lasting investment for homeowners.

The CASTINS-CSB and CASTINS-CWL models represent the pinnacle of contemporary fireplace design with their cast iron construction, enhancing durability and offering superior heat retention. Both models feature intricate designs that not only elevate the aesthetic of any room but also provide effective heating solutions. With the CASTINS series, Hearth and Home Technologies emphasizes the importance of safety with features such as heat shields and advanced flue systems that ensure proper ventilation.

In summary, Hearth and Home Technologies' 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL models are characterized by their innovative technology, elegant design, and efficient heating capabilities. These models cater to a variety of homeowner needs, providing comfort, efficiency, and safety while enhancing interior aesthetics. Whether you’re looking for a robust heating solution or an elegant focal point in your home, Hearth and Home Technologies offers durable and stylish options that stand out in any environment.