Hearth and Home Technologies 810-03201 (PMH), CASTINS-CSB 6Mobile Home, Mobile Home Installation

Page 15

R

Castile Pellet Insert

6Mobile Home

A. Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for instal- lation in a mobile home.

1.An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smoke spillage. Smoke spillage can also set off smoke alarms.

CAUTION

Maintain structural integrity of mobile home:

Floor, wall, ceiling and/or roof. Do NOT cut through:

Floor joist, wall studs or ceiling trusses.

Any supporting material that would affect the structural integrity.

2.The combustion air duct system must be made of metal. It must permit zero clearance to combustible construction and prevent material from dropping into the inlet or into the area beneath the dwelling and contain a rodent screen.

3.The appliance must be secured to the mobile home structure by bolting it to the floor (using lag bolts). Use the same holes that secured the appliance to the ship- ping pallet.

4.The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device.

5.Refer to clearances to combustibles and floor protection requirements on pages 8 & 9 for listings to combus- tibles and appropriate chimney systems.

6.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure.

7.Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home.

8.Installation shall be in accordance with the Manufactur- ers Home & Safety Standard (HUD) CFR 3280, Part 24.

 

 

Spar

rrestor

ap

Storm

ollar

 

 

 

 

 

 

 

 

 

Roof

las

i

g

 

oist S ield

irestop

ppro ed

lass

L

 

 

 

 

or

L

ellet

e

t

Figure 15.1

WARNING

Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

WARNING

Never install in a sleeping room.

September 1, 2008

250-7251F

Page 15

Image 15
Contents 810-02901 MBK 810-03201 PMH Castile Pellet InsertLocation Inside hopper on the top Castile Pellet InsertTable of Contents Glass Specifications Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Mobile Home ApprovedAppliance Location Design, Installation & Location ConsiderationsFire Safety Getting StartedInspect Appliance & Components and Pre-Use Check List Castile Pellet Insert Tools And Supplies NeededAppliance Dimensions 3Dimensions and ClearancesInches Millimeters Castile Pellet Insert Clearance To Combustibles, UL and ULC0mm Clearance To Exposed Section And Face Trim Shown Optional Outside AirLocation Inches Millimeters Castile Pellet Insert Masonry and Zero Clearance FireplacesFloor Protection Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut 4Vent Information Chimney and Exhaust ConnectionVenting Termination Requirements Pipe Selection Chart Castile Pellet Insert Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation 5Venting Systems Castile Pellet Insert Full Reline With Outside Air 6Mobile Home Mobile Home InstallationReversible Top or Rear Flue Adapter Leveling System Top Vent InstallationRear Vent Installation 7Appliance Set-UpItemDescription Assembled ViewPiece. Figure Base Plate Only InstallationCastile Pellet Insert Zero Clearance Trim Support Cont’d Kit Includes SeePanel & Trim Set, Econo Panel Set And Cast Trim SetTop Log Installation Four Piece Log Set InstallationCastile Pellet Insert Thermostat Installation Operating Instructions Fuel Size And MaterialGeneral Operating Information Starting Your First Fire Feed Rate AdjustmentFire Characteristics Castile Pellet Insert Before Your First FireCastile Pellet Insert Iginition Cycles Frequently Asked QuestionsTroubleshooting SymptomPossible Cause Corrective Action Page Symptom Possible Cause Corrective Action Frequency Daily Weekly Monthly Yearly Quick Reference Maintenance ChartCleaning or Inspection 10Maintaining & Servicing Your ApplianceSee Disposal of Ashes Remove Cast Sides for Cleaning & MaintenanceCleaning Firepot with Cleaning Rod & Firepot Scraper Ash Removal from FireboxCleaning Heat Exchanger Chambers & Drop Tube Cleaning Beneath Heat ExchangerCleaning the Exhaust Path Cleaning Exhaust Blower Requires No Lubrication Cleaning the HopperCleaning Convection Blower Requires No Lubrication Cleaning the GlassHigh Ash Fuel Content Maintenance Door Gasket InspectionPreparing Firebox for Non-Burn Season Frequency Yearly Igniter Replacement 35.1 Baffle & Brick Set RemovalRe-installing Baffle & Brick Set Cont’d Component Function Snap Disc #2 Fuel Delivery Interrupt 250F Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 110FCastile Pellet Insert Component Locations Cleaning Rods & Heat Exchanger TubesGlass Size 11-5/8 wide x 17-1/4 high Castile Pellet Insert Exploded ViewsDescription Item # Part Description, Alphabetical Order Part Number Castile Pellet Insert Service Parts and AccessoriesItem No Accessories, Alphabetical Order Item No ApplianceItem # Part Description, Alphabetical Order Date of Service Performed By Description of Service Castile Pellet Insert Service And Maintenance LogCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Castile Pellet Insert Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Telephone Castile Pellet Insert

CASTINS-CWL, CASTINS-CSB, 810-03201 (PMH), 810-02901 (MBK) specifications

Hearth and Home Technologies has made a significant mark in the hearth and home industry with a variety of innovative products, including models like the 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL. These models reflect state-of-the-art design and engineering, ensuring comfort and efficiency in residential heating solutions.

The 810-02901 (MBK) model is designed primarily for modular design, allowing for easy installation and integration into various home architectures. This model features advanced combustion technology that maximizes fuel efficiency while minimizing emissions. It is equipped with an innovative air control system that provides users with precise control over flame height and heat output, enhancing the overall user experience. With features such as a large viewing area, the MBK model provides an attractive look while ensuring optimum safety.

The 810-03201 (PMH) model offers versatile heating options and an elegant design that fits seamlessly into modern interiors. This model is notable for its user-friendly interface, which enables users to control settings with ease. It also has a remarkable heat distribution system, allowing warmth to spread evenly throughout the space, reducing cold spots and enhancing comfort. Additionally, the PMH model is built with durable materials that withstand the test of time, making it a long-lasting investment for homeowners.

The CASTINS-CSB and CASTINS-CWL models represent the pinnacle of contemporary fireplace design with their cast iron construction, enhancing durability and offering superior heat retention. Both models feature intricate designs that not only elevate the aesthetic of any room but also provide effective heating solutions. With the CASTINS series, Hearth and Home Technologies emphasizes the importance of safety with features such as heat shields and advanced flue systems that ensure proper ventilation.

In summary, Hearth and Home Technologies' 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL models are characterized by their innovative technology, elegant design, and efficient heating capabilities. These models cater to a variety of homeowner needs, providing comfort, efficiency, and safety while enhancing interior aesthetics. Whether you’re looking for a robust heating solution or an elegant focal point in your home, Hearth and Home Technologies offers durable and stylish options that stand out in any environment.