Hearth and Home Technologies CASTINS-CSB, CASTINS-CWL Castile Pellet Insert Iginition Cycles

Page 24

R

Castile Pellet Insert

G. Iginition Cycles

1.During each ignition cycle, it is normal to see some smoke in the firebox. The smoke will stop once the fire starts.

2.The convection blower will automatically turn on after your appliance has reached the set temperature. This blower transfers heat from your appliance into the room, and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down.

3.Occasionally the appliance may run out of fuel and shut itself down. When this happens, the red call light will be on. To restart it, fill the hopper and press the reset button. See Figure 21.1 on page 21. When you press the reset button the red call light will go out. Release the button and the light will come back on. You should see a fire shortly. If not, follow the instructions on page 23, “Starting Your First Fire”.

CAUTION

Odors and vapors released during initial operation.

Curing of high temperature paint.

Open windows for air circulation.

Odors may be irritating to sensitive individuals.

WARNING

Fire Risk

Do NOT operate appliance:

With appliance door open.

Firepot floor open.

Cleaning slide plates open. Do NOT store fuel:

Closer than required clearances to com- bustibles to appliance

Within space required for loading or ash removal.

Back side of Firepot

Firepot floor left open

 

 

 

Figure 24.1 - DO NOT LEAVE FIREPOT FLOOR OPEN

H. Frequently Asked Questions

 

 

 

 

 

 

 

ISSUES

 

SOLUTIONS

1.

Metallic noise.

1.

Noise is caused by metal expanding and contracting as

 

 

 

it heats up and cools down, similar to the sound pro-

 

 

 

duced by a furnace or heating duct. This noise does not

 

 

 

affect the operation or longevity of your appliance.

 

 

 

 

2.

Ash buildup on glass.

2.

This is normal. Clean the glass.

 

 

 

 

3.

Glass has turned dirty.

3.

Excessive build up of ash. The lower burn settings will

 

 

 

produce more ash, the higher burn settings produce

 

 

 

less. The more it burns on low the more frequent clean-

 

 

 

ing of the glass is required.

4.

Fire has tall flames with black tails and is lazy.

4.

The feed rate needs to be reduced or the firepot needs

 

 

 

cleaning. Heat exchanger or exhaust blower needs

 

 

 

cleaning.

5.

Smokey start-up or puffs of smoke from the airwash.

5.

Either the firepot is dirty or there is too much fuel at

 

 

 

start-up and not enough air. Close down feed rate 1/4

 

 

 

(6mm) inch at a time until this no longer happens.

 

 

 

 

6.

Large flame at start-up.

6.

This is normal. Flame will settle down once the fire is

 

 

 

established.

 

 

 

 

Page 24

250-7251F

September 1, 2008

Image 24
Contents Castile Pellet Insert 810-02901 MBK 810-03201 PMHCastile Pellet Insert Location Inside hopper on the topTable of Contents Listing and Code Approvals Appliance Certification BTU & Efficiency SpecificationsMobile Home Approved Glass SpecificationsDesign, Installation & Location Considerations Fire SafetyGetting Started Appliance LocationCastile Pellet Insert Tools And Supplies Needed Inspect Appliance & Components and Pre-Use Check List3Dimensions and Clearances Appliance DimensionsCastile Pellet Insert Clearance To Combustibles, UL and ULC 0mm Clearance To Exposed Section And Face TrimShown Optional Outside Air Inches MillimetersCastile Pellet Insert Masonry and Zero Clearance Fireplaces Floor ProtectionMinimum Opening for Masonry and Zero Clearance Fireplaces Location Inches MillimetersStarter hole Mark area of floor to cut 4Vent Information Chimney and Exhaust ConnectionVenting Termination Requirements Pipe Selection Chart Castile Pellet Insert Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation 5Venting Systems Castile Pellet Insert Full Reline With Outside Air Mobile Home Installation 6Mobile HomeTop Vent Installation Rear Vent Installation7Appliance Set-Up Reversible Top or Rear Flue Adapter Leveling SystemAssembled View ItemDescriptionBase Plate Only Installation Castile Pellet Insert Zero Clearance Trim Support Cont’dKit Includes See Piece. FigurePanel Set And Cast Trim Set Panel & Trim Set, EconoFour Piece Log Set Installation Top Log InstallationCastile Pellet Insert Thermostat Installation Operating Instructions Fuel Size And MaterialGeneral Operating Information Feed Rate Adjustment Fire CharacteristicsCastile Pellet Insert Before Your First Fire Starting Your First FireFrequently Asked Questions Castile Pellet Insert Iginition CyclesTroubleshooting SymptomPossible Cause Corrective Action Page Symptom Possible Cause Corrective Action Quick Reference Maintenance Chart Cleaning or Inspection10Maintaining & Servicing Your Appliance Frequency Daily Weekly Monthly YearlyRemove Cast Sides for Cleaning & Maintenance Cleaning Firepot with Cleaning Rod & Firepot ScraperAsh Removal from Firebox See Disposal of AshesCleaning Heat Exchanger Chambers & Drop Tube Cleaning Beneath Heat ExchangerCleaning the Exhaust Path Cleaning the Hopper Cleaning Convection Blower Requires No LubricationCleaning the Glass Cleaning Exhaust Blower Requires No LubricationHigh Ash Fuel Content Maintenance Door Gasket InspectionPreparing Firebox for Non-Burn Season Frequency Yearly Igniter Replacement Baffle & Brick Set Removal 35.1Re-installing Baffle & Brick Set Cont’d Component Function Vacuum Switch Wiring Harness See .1 belowSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FCleaning Rods & Heat Exchanger Tubes Castile Pellet Insert Component LocationsCastile Pellet Insert Exploded Views Glass Size 11-5/8 wide x 17-1/4 highDescription Castile Pellet Insert Service Parts and Accessories Item # Part Description, Alphabetical Order Part NumberItem No Accessories, Alphabetical Order Item No ApplianceItem # Part Description, Alphabetical Order Castile Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Homeowner’s Notes Castile Pellet Insert Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Castile Pellet Insert Telephone

CASTINS-CWL, CASTINS-CSB, 810-03201 (PMH), 810-02901 (MBK) specifications

Hearth and Home Technologies has made a significant mark in the hearth and home industry with a variety of innovative products, including models like the 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL. These models reflect state-of-the-art design and engineering, ensuring comfort and efficiency in residential heating solutions.

The 810-02901 (MBK) model is designed primarily for modular design, allowing for easy installation and integration into various home architectures. This model features advanced combustion technology that maximizes fuel efficiency while minimizing emissions. It is equipped with an innovative air control system that provides users with precise control over flame height and heat output, enhancing the overall user experience. With features such as a large viewing area, the MBK model provides an attractive look while ensuring optimum safety.

The 810-03201 (PMH) model offers versatile heating options and an elegant design that fits seamlessly into modern interiors. This model is notable for its user-friendly interface, which enables users to control settings with ease. It also has a remarkable heat distribution system, allowing warmth to spread evenly throughout the space, reducing cold spots and enhancing comfort. Additionally, the PMH model is built with durable materials that withstand the test of time, making it a long-lasting investment for homeowners.

The CASTINS-CSB and CASTINS-CWL models represent the pinnacle of contemporary fireplace design with their cast iron construction, enhancing durability and offering superior heat retention. Both models feature intricate designs that not only elevate the aesthetic of any room but also provide effective heating solutions. With the CASTINS series, Hearth and Home Technologies emphasizes the importance of safety with features such as heat shields and advanced flue systems that ensure proper ventilation.

In summary, Hearth and Home Technologies' 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL models are characterized by their innovative technology, elegant design, and efficient heating capabilities. These models cater to a variety of homeowner needs, providing comfort, efficiency, and safety while enhancing interior aesthetics. Whether you’re looking for a robust heating solution or an elegant focal point in your home, Hearth and Home Technologies offers durable and stylish options that stand out in any environment.