LG Electronics LSC183VMA service manual Connect the cable to the indoor unit

Page 27

CAUTIONI

If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.

Main power source

Air

Conditioner

Circuit Breaker Use a circuit breaker or time delay fuse.

3) Connect the cable to the indoor unit

1.Connect the wires to the terminals on the control board individually according to the outdoor unit connection.

Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

(Refer to Wiring diagram on page10.)

WARNING

Be sure to refer to the wiring diagram label inside the grille and carry out the correct field wiring.

Wrong wiring can cause the unit to misoperate to result in a fire hazard.

Check local electrical codes and any specified wiring instructions or limitations.

Connecting cable

-27-

Image 27
Contents Room Air Conditioner Contents Code Type Code of Model Meaning Details of 2003 LG Model NameIndoor Unit FunctionsSetting the Time or Timer Timer Selection Operation ON/OFF Operation Mode SelectionRoom, Temperature Checking Temperature SettingLSC183VMA Product ReferencesDimensions Indoor UnitIndoor Unit Gas side Outdoor Unit 18KCooling Only Models Refrigeration Cycle Diagram18K Cooling Only Models Wiring DiagramCooling Mode Operation Healthy Dehumidification ModeOperation Details Defrost Control Heating Mode OperationFuzzy Operation C/O Model Fuzzy Operation H/P ModelFuzzy Operation for Cooling Fuzzy Operation for Heating On-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer OperationOff-Timer ↔ On-Timer Operation Sleep Timer OperationTest operation Jet Cool Mode Operation H/P ModelRemote Control Operation Mode Forced OperationHeating Model Compressor on IndicatorDisplay Function Self-diagnosis FunctionPiping length and elevation InstallationInstallation of indoor, Outdoor unit Select the best locationDrain hose junction Preparing work for InstallationOpen panel front Cover pipe and cover side removeHow to fix installation plate Flaring Work and Connection of Piping Flaring workConnection of piping Indoor Wrap the insulation material around the connecting portion Indoor unit installationFor right piping. Follow the instruction below Installation Information For right piping Good caseBad case Connection of the pipes-OutdoorConnection of the cable Connecting The Cable Between Indoor Unit and Outdoor UnitFor strand wiring Connection method of the connecting cableExampleTo check the drainage Checking the Drainage and forming the pipingsChecking the drainage Form the pipingConnect the cable to the indoor unit Circuit Breaker Use a circuit breaker or time delay fusePreparation Air PurgingAir purging Air purging with vacuum pumpFinishing the job EvacuationDrive three screws Panel Front AssemblySettlement of outdoor unit Prepare remote controlPump Down Procedure Test RunningOperation Name and Function-Remote ControlTo remove the Control Box To remove the Grille from the ChassisTo remove the Evaporator Before removing the Turbo FanTo remove the Motor Way Valve Liquid Side Way, 3-way ValvePurge the air from the system ProcedureAir purging Check for gas leakagePumping down Air purging of the charge hoseSet the 2-way valve to the closed position Re-air purging Gas leakage Balance refrigerant of the 2-way, 3-way valvesAll amount of refrigerant leaked EvacuationPurge the air from the charge hose Gas ChargingAfter Evacuation Connect the charge hose to the charging cylinderTrouble analysis Cycle Troubleshooting GuideYES Product is not operate with the remote controller Compressor/Outdoor Fan are unable to drive Check connecting condition of the CN-MOTOR Connector When Indoor Fan does not operateWhen Vertical Louver does not operate When a comunication error occurs Indoor Unit Phenomena in case of connecting errorOutdoor Unit Voltage of Connectors according to No. of pinsIndoor Fan Speed Main PWB ASSYIndoor Unit Electronic Control DeviceModel Main PWB ASSYOutdoor UnitDisplay PWB Assembly SUB PCB ASM Indoor UnitMicom Outdoor UnitExploded View and Replacement Parts List Location Description Remarks LSC183VMA Parts ListindoorW0CZZ Outdoor unit18KLocation Description QTY Remarks LSC183VMA Parts ListoutdoorMemo Memo August