LG Electronics LSC183VMA service manual Product References

Page 6

Product References

 

 

Items

 

Unit

LSC183VMA

Power Supply

 

 

ø , V, Hz

1, 208/230, 60

Cooling Capacity

 

 

BTU/h

18,000/18,000

Input

 

 

W

1,900/1,900

Running Current

 

 

A

9.0/9.0

COMP. Locked Rotor AMP.

 

A

47

E.E.R

 

 

BTU/hW

9.5/9.5

Air Circulation

 

 

 

m3/min(cfm)

11.9(420)

Moisture Removal

 

 

 

l/h(pts/hr)

2.5(5.3)

Noise Level

 

Indoor, High

 

dB(A)±3

45

(Sound

 

Med

 

dB(A)±3

42

Pressure, 1m)

 

Low

 

dB(A)±3

39

 

 

Outdoor, Max

 

dB(A)±3

53

Features

 

Temperature Control

 

 

Thermistor

 

 

Air Deflection

 

 

4-way

 

 

Steps, Fan/Cool

 

 

3/4

 

 

 

 

 

 

 

 

Airflow Direction Control(up&down)

Auto

 

 

 

 

 

 

 

 

Airflow Direction Control(left&right)

Manual

 

 

Remocon Type

 

 

Wireless LCD

 

 

Setting Temperature Range, Cooling Mode

64~86°F

 

 

 

 

 

 

 

 

Temperature Increment

 

 

2°F

 

 

Auto Operation(electronic control)

Yes

 

 

Self Diagnosis

 

 

Yes

 

 

 

 

 

 

 

 

Timer

 

 

24hr, On/Off

 

 

Sleep Operation

 

 

Yes

 

 

Healthy Dehumidification Mode

Yes

 

 

Restart Delay

 

minutes

3

Refrigerant(R-22) Charge

 

 

g(oz)

1,280(45.2)

 

 

 

 

 

 

Power cord

 

 

AWG #: P*mm2

14:3*2.5

Fuse or breaker Capacity

 

 

A

20

Connecting Cable

 

 

AWG #: P*mm2

18:4*0.75

Connecting Tube

 

Liquid Side

 

mm(in)

6.35(1/4)

(ø . Socket Flare)

 

Gas Side

 

mm(in)

15.88(5/8)

 

 

Length, std

 

m(ft)

7.5(24.6)

 

 

 

 

 

Additional Drain Hose(Outer Dia.)

 

mm(in)

19(6/8)

Dimensions

 

Indoor

 

mm

928*522*147

(WxHxD)

 

 

 

in

36.5*20.6*5.8

 

 

Outdoor

 

mm

870*655*320

 

 

 

 

in

34.3*25.812.6

Net Weight

 

Indoor

 

kg(lbs)

16(35.3)

 

 

Outdoor

 

kg(lbs)

58(127.9)

 

 

 

 

 

 

NOTE: Please refer to Label Quality on the product since this specification may be changed for improving performance

-6-

Image 6
Contents Room Air Conditioner Contents Details of 2003 LG Model Name Code Type Code of Model MeaningFunctions Indoor UnitTemperature Setting Operation ON/OFF Operation Mode SelectionRoom, Temperature Checking Setting the Time or Timer Timer SelectionProduct References LSC183VMADimensions Indoor UnitIndoor Unit Outdoor Unit 18K Gas sideRefrigeration Cycle Diagram Cooling Only ModelsWiring Diagram 18K Cooling Only ModelsCooling Mode Operation Healthy Dehumidification ModeOperation Details Heating Mode Operation Defrost ControlFuzzy Operation C/O Model Fuzzy Operation H/P ModelFuzzy Operation for Cooling Fuzzy Operation for Dehumidification On-Timer OperationAirflow Speed Selection Fuzzy Operation for HeatingSleep Timer Operation Off-Timer OperationOff-Timer ↔ On-Timer Operation Chaos Swing ModeForced Operation Jet Cool Mode Operation H/P ModelRemote Control Operation Mode Test operationSelf-diagnosis Function Compressor on IndicatorDisplay Function Heating ModelSelect the best location InstallationInstallation of indoor, Outdoor unit Piping length and elevationCover pipe and cover side remove Preparing work for InstallationOpen panel front Drain hose junctionHow to fix installation plate Flaring Work and Connection of Piping Flaring workConnection of piping Indoor Indoor unit installation Wrap the insulation material around the connecting portionConnection of the pipes-Outdoor Installation Information For right piping Good caseBad case For right piping. Follow the instruction belowConnecting The Cable Between Indoor Unit and Outdoor Unit Connection of the cableConnection method of the connecting cableExample For strand wiringForm the piping Checking the Drainage and forming the pipingsChecking the drainage To check the drainageCircuit Breaker Use a circuit breaker or time delay fuse Connect the cable to the indoor unitAir purging with vacuum pump Air PurgingAir purging PreparationEvacuation Finishing the jobPanel Front Assembly Drive three screwsTest Running Prepare remote controlPump Down Procedure Settlement of outdoor unitName and Function-Remote Control OperationTo remove the Grille from the Chassis To remove the Control BoxTo remove the Evaporator Before removing the Turbo FanTo remove the Motor Way, 3-way Valve Way Valve Liquid SideCheck for gas leakage ProcedureAir purging Purge the air from the systemPumping down Air purging of the charge hoseSet the 2-way valve to the closed position Re-air purging Balance refrigerant of the 2-way, 3-way valves Gas leakageEvacuation All amount of refrigerant leakedConnect the charge hose to the charging cylinder Gas ChargingAfter Evacuation Purge the air from the charge hoseCycle Troubleshooting Guide Trouble analysisYES Product is not operate with the remote controller Compressor/Outdoor Fan are unable to drive When Indoor Fan does not operate Check connecting condition of the CN-MOTOR ConnectorWhen Vertical Louver does not operate When a comunication error occurs Phenomena in case of connecting error Indoor UnitOutdoor Unit Voltage of Connectors according to No. of pinsIndoor Fan Speed Electronic Control Device Main PWB ASSYIndoor UnitMain PWB ASSYOutdoor Unit ModelDisplay PWB Assembly Indoor Unit SUB PCB ASMOutdoor Unit MicomExploded View and Replacement Parts List Parts Listindoor Location Description Remarks LSC183VMAOutdoor unit18K W0CZZParts Listoutdoor Location Description QTY Remarks LSC183VMAMemo Memo August