LG Electronics service manual Parts Listoutdoor, Location Description QTY Remarks LSC183VMA

Page 60

Parts List(outdoor)

LOCATION

DESCRIPTION

PART No.

Q'TY

REMARKS

No.

 

LSC183VMA

 

 

 

 

 

 

 

 

261704

TRANSFORMER, POWER

6171AQ3198A

1

 

 

 

 

 

 

430411

BASE ASSY, WELD(OUTDOOR)

3041A30003F

1

R

 

 

 

 

 

435511

COVER ASSY, CONTROL(OUTDOOR)

3551AR7184T

1

R

 

 

 

 

 

435512

COVER ASSY, TOP(OUTDOOR)

3H03266J

1

R

 

 

 

 

 

437210

PANEL ASSY, FRONT(OUTDOOR)

3721A20005H

1

R

 

 

 

 

 

437212

PANEL ASSY, REAR

3720AP0003D

1

R

 

 

 

 

 

546810

MOTOR ASSY, OUTDOOR

4681A20013M

1

R

 

 

 

 

 

550140

ISOLATOR, COMP

4H00982E

3

R

 

 

 

 

 

552111

TUBE ASSY, CAPILLARY

5425AR3847L

1

R

 

 

 

 

 

552203-2

VALVE, SERVICE

2A00392N

1

R

 

 

 

 

 

552203-3

VALVE, SERVICE

2H02479F

1

R

 

 

 

 

 

554031

CONDENSER ASSY, BENT

5403A20022B

1

R

 

 

 

 

 

554160

COMPRESSOR SET

2520UMLK1BA

1

R

 

 

 

 

 

559010

FAN ASSY, PROPELLER

1A00195B

1

R

 

 

 

 

 

567502

O.L.P

6750U-L025A

1

R

 

 

 

 

 

649950

CONTROL BOX ASSY, OUTDOOR

4781AR1528U

1

R

 

 

 

 

 

668711

PWB(PCB) ASSY, MAIN(OUTDOOR)

6871A10036P

1

R

 

 

 

 

 

W0CZZ

CAPACITOR, DRAWING

6120AR2194B

1

R

 

 

 

 

 

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)

-60-

Image 60
Contents Room Air Conditioner Contents Details of 2003 LG Model Name Code Type Code of Model MeaningFunctions Indoor UnitOperation ON/OFF Operation Mode Selection Room, Temperature CheckingTemperature Setting Setting the Time or Timer Timer SelectionProduct References LSC183VMADimensions Indoor UnitIndoor Unit Outdoor Unit 18K Gas sideRefrigeration Cycle Diagram Cooling Only ModelsWiring Diagram 18K Cooling Only ModelsCooling Mode Operation Healthy Dehumidification ModeOperation Details Heating Mode Operation Defrost ControlFuzzy Operation C/O Model Fuzzy Operation H/P ModelFuzzy Operation for Cooling On-Timer Operation Airflow Speed SelectionFuzzy Operation for Dehumidification Fuzzy Operation for HeatingOff-Timer Operation Off-Timer ↔ On-Timer OperationSleep Timer Operation Chaos Swing ModeJet Cool Mode Operation H/P Model Remote Control Operation ModeForced Operation Test operationCompressor on Indicator Display FunctionSelf-diagnosis Function Heating ModelInstallation Installation of indoor, Outdoor unitSelect the best location Piping length and elevationPreparing work for Installation Open panel frontCover pipe and cover side remove Drain hose junctionHow to fix installation plate Flaring Work and Connection of Piping Flaring workConnection of piping Indoor Indoor unit installation Wrap the insulation material around the connecting portionInstallation Information For right piping Good case Bad caseConnection of the pipes-Outdoor For right piping. Follow the instruction belowConnecting The Cable Between Indoor Unit and Outdoor Unit Connection of the cableConnection method of the connecting cableExample For strand wiringChecking the Drainage and forming the pipings Checking the drainageForm the piping To check the drainageCircuit Breaker Use a circuit breaker or time delay fuse Connect the cable to the indoor unitAir Purging Air purgingAir purging with vacuum pump PreparationEvacuation Finishing the jobPanel Front Assembly Drive three screwsPrepare remote control Pump Down ProcedureTest Running Settlement of outdoor unitName and Function-Remote Control OperationTo remove the Grille from the Chassis To remove the Control BoxTo remove the Evaporator Before removing the Turbo FanTo remove the Motor Way, 3-way Valve Way Valve Liquid SideProcedure Air purgingCheck for gas leakage Purge the air from the systemPumping down Air purging of the charge hoseSet the 2-way valve to the closed position Re-air purging Balance refrigerant of the 2-way, 3-way valves Gas leakageEvacuation All amount of refrigerant leakedGas Charging After EvacuationConnect the charge hose to the charging cylinder Purge the air from the charge hoseCycle Troubleshooting Guide Trouble analysisYES Product is not operate with the remote controller Compressor/Outdoor Fan are unable to drive When Indoor Fan does not operate Check connecting condition of the CN-MOTOR ConnectorWhen Vertical Louver does not operate When a comunication error occurs Phenomena in case of connecting error Indoor UnitOutdoor Unit Voltage of Connectors according to No. of pinsIndoor Fan Speed Electronic Control Device Main PWB ASSYIndoor UnitMain PWB ASSYOutdoor Unit ModelDisplay PWB Assembly Indoor Unit SUB PCB ASMOutdoor Unit MicomExploded View and Replacement Parts List Parts Listindoor Location Description Remarks LSC183VMAOutdoor unit18K W0CZZParts Listoutdoor Location Description QTY Remarks LSC183VMAMemo Memo August