Haier 1590 SA, 3150 SB Warnings, Fire And Explosion Hazard, Pressurized Equipment Hazard, 310622L

Page 3
Warnings

Warnings

Warnings

The following general warnings are for the safe setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbols alert you to general warnings and the hazard symbols refer to procedure-specific risks. Refer back to these Warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

FIRE AND EXPLOSION HAZARD Warning

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground equipment and conductive objects in work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop operating and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only.

Do not alter or modify equipment.

For professional use only.

Use equipment only for its intended purpose. Call your Graco distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not use hoses to pull equipment.

Comply with all applicable safety regulations.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal- lowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

310622L

3

Image 3
Contents 310622L Model SA3AAA ShownInstructions/Parts List High Sanitation PumpsTechnical Data ContentsContents Dimensional DrawingPRESSURIZED EQUIPMENT HAZARD WarningsWarnings FIRE AND EXPLOSION HAZARDPERSONAL PROTECTIVE EQUIPMENT BURN HAZARDLeak Detection System InstallationInstallation General InformationFluid Suction Line Ground Wire ConnectionMountings Air LineTypical Installation FIG. 3 Typical Floor-Mount InstallationFluid Outlet Line Changing the Orientation of the Fluid Inlet and Outlet Ports Air Exhaust VentilationFIG. 4 Orientation of Fluid Ports C Air regulator D Air line quick disconnect FIG. 5 Venting Exhaust AirE Master air valve for accessories F Air line filter P Muffler A Air supply line B Bleed-type master air valve required for pumpSanitizing the Pump Before First Use Pressure Relief ProcedureStarting and Adjusting the Pump OperationLubrication MaintenanceRoutine Cleaning of Product Contact Section of Pump MaintenanceTask Preventive Maintenance ScheduleMaintenance Person Operator310622L Follow Pressure Relief Proce TroubleshootingTroubleshooting PROBLEMTighten clamp erly/cleanly due to imbalanceLeak in inlet or outlet sanitary fit Loose sanitary clampDisassembly ServiceRepairing the Air Valve ServiceReassembly 8. Install the valve carriage 105 so its tabs slip into the grooves on the narrow end of the actuator pis- tons 111. See FIG Check Valve Repair 3A Ball Check AssemblyTI8769a Service For Sanitary Ball Check pumps remove ball gasketSanitary Ball Check Assembly Flapper Check AssemblyTools Required Diaphragm Repairshaft side Sanitary Pump3A Pump diaphragm plate side high strength thread lockBearing and Air Gasket Removal Service Pump Matrix Pump Matrix3150 Stainless Steel Sanitary Pumps 1590 Stainless Steel Sanitary PumpsParts Drawing Sanitary Ball Check Valve AssemblyFlapper Check Valve Assembly Sanitary Diaphragm AssemblyParts List Parts ListPump Configuration Parts List Inlet and Outlet Parts List3150 Diaphragm Material Parts ListIndicates replacement parts † Indicates a recommended spare part PartIndicates replacement parts † Indicates a recommended spare part Check Ball Material Parts Listscrew threads and torque to 130-150 in-lbs center housing boreApply medium strength adhesive to outside Apply a medium strength thread locker toLeak Detector and Pump Stand Parts List Air Section PartsFluid Section Parts 15D990 Leak Detector AccessoriesAccessories 3150 Conversion KitsTI8778a Dimensional DrawingModel ModelTechnical Data Santoprene is a registered trademark of the Monsanto CoLoctite is a registered trademark of the Loctite Corporation To find Fluid Outlet Pressure Performance Chart1590 3A Performance Chart Test Conditions Pump tested in water with inlet submerged3A Ball Check Valve Pumps Sanitary Ball Check Valve PumpsFlapper Check Valve Pumps Santoprene is a registered trademark of the Monsanto Co 3150 3A Performance Chart 310622L Graco Information Graco Standard Pump WarrantyExtended Product Warranty Graco Warranties