Pump Matrix
Pump Matrix
3150 Stainless Steel Sanitary Pumps
Your Model No. is marked on the pump’s serial plate. To determine the Model No. of your pump from the follow- ing matrix, select the six digits which describe your pump, working from left to right. The first digit is always S, designating Graco Sanitary diaphragm pumps. The remaining five digits define the pump configuration, size, and materials of construction. For example, a sanitary
ball check pump with a three inch inlet and outlet, San- toprene balls and diaphragms, a pump stand, and no leak detector is model SB3661. To order replace- ment parts, refer to the part lists on pages 26 - 31. The digits in the matrix do not correspond to the reference numbers in the parts drawing and lists.
Sanitary | Pump | Inlet and Outlet | Diaphragm | Check Ball | Leak Detector, | ||||
Pump | Configuration | (in.) |
|
| Material | Pump Stand | |||
|
|
|
|
|
|
|
|
|
|
S - (for all pumps) | A 3A Approved | 1 | 1 1/2 x 1 1/2 | A | 3A Approved | A | 3A Approved | A | Leak Detec- |
|
|
|
|
| (EPDM) |
| (PTFE) |
| tor and Pump |
|
|
|
|
|
|
|
|
| Stand |
|
|
|
|
|
|
|
|
|
|
| B Ball Check | 2 | 2 x 2 | 6 | Santoprene® | 6 | Santoprene® | 1 | Pump Stand |
| F Flapper Check | 3 | 3 x 3 | 7 | 7 | 3 | None | ||
|
|
|
|
|
|
|
|
|
|
|
| 4 | 4 x 4 | 8 | fluoroelas- | 8 | fluoroelas- |
|
|
|
|
|
|
| tomer |
| tomer |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | 3 x 2 |
|
| F | Flapper |
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | NONE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1590 Stainless Steel Sanitary Pumps
The table below shows all available configurations for 1590 Stainless Steel Sanitary Pumps.
Model Number | Pump | Inlet and Outlet | Check Valve | Check Ball Mate- | Diaphragm |
| Configuration | (in.) | Style | rial | Material |
|
|
|
|
|
|
SABAAA | 3A Approved | 2 x 2 | 3A Ball Checks | 3A PTFE | 3A Approved |
|
|
|
|
| EPDM |
|
|
|
|
|
|
SBBAAA | 2 x 2 | 3A Ball Checks | 3A PTFE | 3A Approved | |
| No Leak Detector |
|
|
| EPDM |
|
|
|
|
|
|
SBBA11 | 2 x 2 | 3A Ball Checks | (3A) PTFE | PTFE | |
| No Leak Detector |
|
|
|
|
|
|
|
|
|
|
SBBA22 | 2 x 2 | 3A Ball Checks | Santoprene | Santoprene | |
| No Leak Detector |
|
|
|
|
|
|
|
|
|
|
310622L | 25 |