Haier 3150 SA, 3150 SB, 3150 SF Accessories, Conversion Kits, 15D990 Leak Detector, 310622L

Page 32
Accessories

Accessories

Accessories

15D990 Leak Detector

Sensor and control package that monitors the dia- phragm condition. In case of diaphragm failure, the con- trol will provide an audible alarm and relay contacts for remote alarms or solenoids. See Leak Detector manual 311200.

To be15D990 Leak Detector approved, a leak detection system must be used on the pump. Any pump with a leak detec- tor installed is NOT Atex approved.

3150 Conversion Kits

15H461 3A Approved Ball Check Conversion Kit

Converts flapper check valve to 3A ball check valve. Includes four seats and four ball stops. Balls need to be ordered separately.

Part No.

Description

Qty.

 

 

 

15B406

SEAT, ball

4

 

 

 

15H460

GASKET, 4 in.

12

 

 

 

510490

CLAMP, 4 in.

4

 

 

 

15H407

STOP, ball

4

 

 

 

15D989 Flapper Valve Conversion Kit

Converts ball check valve to flapper check valve. Includes four flapper assemblies. See Flapper Valve Assembly, page 26.

Part No.

Description

Qty.

 

 

 

513548

GASKET, 4 in.

8

 

 

 

249535

MODULE, flapper

4

 

 

 

15E285 Sanitary Ball Check Conversion Kit

Converts flapper check valve to sanitary ball check valve. Includes four seats and four ball stops. Balls need to be ordered separately.

Part No.

Description

Qty.

 

 

 

15D026

SEAT, ball

4

 

 

 

15D346

GASKET, ball stop

4

 

 

 

32

310622L

Image 32
Contents Model SA3AAA Shown Instructions/Parts ListHigh Sanitation Pumps 310622LContents ContentsDimensional Drawing Technical DataWarnings WarningsFIRE AND EXPLOSION HAZARD PRESSURIZED EQUIPMENT HAZARDBURN HAZARD PERSONAL PROTECTIVE EQUIPMENTInstallation InstallationGeneral Information Leak Detection SystemGround Wire Connection MountingsAir Line Fluid Suction LineFluid Outlet Line Typical InstallationFIG. 3 Typical Floor-Mount Installation FIG. 4 Orientation of Fluid Ports Changing the Orientation of the Fluid Inlet and Outlet PortsAir Exhaust Ventilation FIG. 5 Venting Exhaust Air E Master air valve for accessories F Air line filter P MufflerA Air supply line B Bleed-type master air valve required for pump C Air regulator D Air line quick disconnectPressure Relief Procedure Starting and Adjusting the PumpOperation Sanitizing the Pump Before First UseMaintenance Routine Cleaning of Product Contact Section of PumpMaintenance LubricationPreventive Maintenance Schedule Maintenance PersonOperator TaskMaintenance Troubleshooting TroubleshootingPROBLEM Follow Pressure Relief Proceerly/cleanly due to imbalance Leak in inlet or outlet sanitary fitLoose sanitary clamp Tighten clampService Repairing the Air ValveService DisassemblyReassembly 8. Install the valve carriage 105 so its tabs slip into the grooves on the narrow end of the actuator pis- tons 111. See FIG 3A Ball Check Assembly Check Valve RepairService For Sanitary Ball Check pumps remove ball gasket Sanitary Ball Check AssemblyFlapper Check Assembly TI8769aDiaphragm Repair Tools RequiredSanitary Pump 3A Pumpdiaphragm plate side high strength thread lock shaft sideBearing and Air Gasket Removal 310622L Pump Matrix 3150 Stainless Steel Sanitary Pumps1590 Stainless Steel Sanitary Pumps Pump MatrixSanitary Ball Check Valve Assembly Flapper Check Valve AssemblySanitary Diaphragm Assembly Parts DrawingParts List Pump Configuration Parts ListInlet and Outlet Parts List Parts ListDiaphragm Material Parts List Indicates replacement parts † Indicates a recommended spare partPart 3150Check Ball Material Parts List Indicates replacement parts † Indicates a recommended spare partcenter housing bore Apply medium strength adhesive to outsideApply a medium strength thread locker to screw threads and torque to 130-150 in-lbsFluid Section Parts Leak Detector and Pump Stand Parts ListAir Section Parts Accessories Accessories3150 Conversion Kits 15D990 Leak DetectorDimensional Drawing ModelModel TI8778aLoctite is a registered trademark of the Loctite Corporation Technical DataSantoprene is a registered trademark of the Monsanto Co Performance Chart 1590 3A Performance ChartTest Conditions Pump tested in water with inlet submerged To find Fluid Outlet PressureFlapper Check Valve Pumps 3A Ball Check Valve PumpsSanitary Ball Check Valve Pumps Technical Data 3150 3A Performance Chart Model Graco Standard Pump Warranty Extended Product WarrantyGraco Warranties Graco Information