Haier 1590 SB Technical Data, Santoprene is a registered trademark of the Monsanto Co, Model

Page 34

Model 1590

Model 1590

Technical Data

Maximum fluid working pressure

120 psi (0.8 MPa, 8 bar)

Air pressure operating range

20-120 psi (0.14-0.8 MPa, 1.4-8 bar)

Maximum air consumption

125 scfm

Air consumption at 70 psi air inlet pressure/60 gpm

50 scfm (see chart)

Maximum free-flow delivery

100 gpm (378.5 l/min)

Maximum pump speed

200 cpm

* Gallons (Liters) per cycle

0.5 (1.96)

Maximum suction lift

28 ft (8.5 m) wet, 15 ft (4.57 m) dry

Maximum size pumpable solids

5/8 in. (15.9 mm)

** Maximum Noise Level at 100 psi, full flow

90 dBa

** Sound Power Level

103 dBa

** Noise Level at 70 psi and 50 cpm

85 dBa

Maximum fluid operating temperature is based on the

PTFE 220°F (104.4°C)

following maximum diaphragm, ball, and o-ring tempera-

Santoprene® 180°F (82.2°C)

ture ratings

3A Approved EPDM 275°F (135°C)

Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 in. npt(f)

Wetted parts

***All fluid contact materials are FDA-compliant and meet the United States Code of Federal Regulations (CFR) Title 21, Section 177.

All fluid contact materials are FDA-compliant.

Wetted materials on all models . . . . . . . . . . . . . . . . . . . . 316 SST, 3A Approved EPDM, PTFE, Wetted material depending on model. . . . . . . . . . . . . . . . Santoprene®, 3A Approved EPDM, PTFE

CAUTION:

Santoprene® may be used only with non-fatty, non-oily foods or alcohols up to 15%.

Non-wetted external parts . . . . . . . . . . . . . . . . . . . . . . . .

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

300 series stainless steel, polyester (labels), LDPE foam (gasket)

97 lb (44 kg)

Santoprene® is a registered trademark of the Monsanto Co.

Loctite® is a registered trademark of the Loctite Corporation.

*Displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.

**Noise levels measured with the pump mounted on the stand. Sound power measured per ISO Standard 9614-1.

***The pump user must verify that the construction materials meet their specific application requirements.

34

310622L

Image 34
Contents High Sanitation Pumps Model SA3AAA ShownInstructions/Parts List 310622LDimensional Drawing ContentsContents Technical DataFIRE AND EXPLOSION HAZARD WarningsWarnings PRESSURIZED EQUIPMENT HAZARDBURN HAZARD PERSONAL PROTECTIVE EQUIPMENTGeneral Information InstallationInstallation Leak Detection SystemAir Line Ground Wire ConnectionMountings Fluid Suction LineFIG. 3 Typical Floor-Mount Installation Typical InstallationFluid Outlet Line Air Exhaust Ventilation Changing the Orientation of the Fluid Inlet and Outlet PortsFIG. 4 Orientation of Fluid Ports A Air supply line B Bleed-type master air valve required for pump FIG. 5 Venting Exhaust AirE Master air valve for accessories F Air line filter P Muffler C Air regulator D Air line quick disconnectOperation Pressure Relief ProcedureStarting and Adjusting the Pump Sanitizing the Pump Before First UseMaintenance MaintenanceRoutine Cleaning of Product Contact Section of Pump LubricationOperator Preventive Maintenance ScheduleMaintenance Person TaskMaintenance PROBLEM TroubleshootingTroubleshooting Follow Pressure Relief ProceLoose sanitary clamp erly/cleanly due to imbalanceLeak in inlet or outlet sanitary fit Tighten clampService ServiceRepairing the Air Valve DisassemblyReassembly 8. Install the valve carriage 105 so its tabs slip into the grooves on the narrow end of the actuator pis- tons 111. See FIG 3A Ball Check Assembly Check Valve RepairFlapper Check Assembly Service For Sanitary Ball Check pumps remove ball gasketSanitary Ball Check Assembly TI8769aDiaphragm Repair Tools Requireddiaphragm plate side high strength thread lock Sanitary Pump3A Pump shaft sideBearing and Air Gasket Removal Reassembly 1590 Stainless Steel Sanitary Pumps Pump Matrix3150 Stainless Steel Sanitary Pumps Pump MatrixSanitary Diaphragm Assembly Sanitary Ball Check Valve AssemblyFlapper Check Valve Assembly Parts DrawingInlet and Outlet Parts List Parts ListPump Configuration Parts List Parts ListPart Diaphragm Material Parts ListIndicates replacement parts † Indicates a recommended spare part 3150Check Ball Material Parts List Indicates replacement parts † Indicates a recommended spare partApply a medium strength thread locker to center housing boreApply medium strength adhesive to outside screw threads and torque to 130-150 in-lbsAir Section Parts Leak Detector and Pump Stand Parts ListFluid Section Parts 3150 Conversion Kits AccessoriesAccessories 15D990 Leak DetectorModel Dimensional DrawingModel TI8778aSantoprene is a registered trademark of the Monsanto Co Technical DataLoctite is a registered trademark of the Loctite Corporation Test Conditions Pump tested in water with inlet submerged Performance Chart1590 3A Performance Chart To find Fluid Outlet PressureSanitary Ball Check Valve Pumps 3A Ball Check Valve PumpsFlapper Check Valve Pumps Model 3150 3A Performance Chart Model Graco Warranties Graco Standard Pump WarrantyExtended Product Warranty Graco Information