11. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia
Connection & Test Pressures
Gas (Rp ½ at rear | Electric |
|
|
|
| ||
Natural Gas | 1kPa | 230V 50 Hz |
|
|
|
| |
Propane | 2.54 kPa |
|
|
|
|
| |
See appliance data badge for test pressures. |
|
|
|
|
| ||
Dimensions |
|
|
|
|
|
| |
Overall height |
| minimum 900 mm |
|
| maximum 925 mm |
| |
Overall width |
|
| 900 mm |
|
| ||
Overall depth |
| 600 mm (to fascia); 650 mm (over handles) |
| ||||
Minimum space above hotplate |
|
| 650 mm |
|
| ||
Refer to ‘Positioning the Cooker’. |
|
|
|
|
|
| |
Ratings |
|
|
|
|
|
| |
Hotplate | Natural Gas 1.0 kPa |
|
| LP Gas 2.54 kPa |
| ||
Input | Injector | Bypass | Input | Injector | Bypass | ||
| |||||||
Wok burner | 15.2 | internal 112 | 90 | 15.0 | internal 66 | 54 | |
external 164 | external 91 | ||||||
|
|
|
|
| |||
Large burner | 12.3 | 165 | 80 | 12.0 | 89 | 41 | |
Medium burners | 6.2 | 115 | 56 | 6.2 | 67 | 33 | |
Small burner | 3.7 | 92 | 48 | 3.3 | 48 | 25 |
Gas burner inputs based on Gross Caloric Value.
Oven Efficiency
Ovens |
| Main oven | Tall oven |
| Forced air convection | Forced air convection | |
|
| ||
Maximum power output @ 230V 50 Hz | 2.5 kW | 2.5 kW | |
Energy eciency class on a scale of A (more ecient) to G (less ecient) | A | A | |
Energy consumption based on standard load | 0.90 kWh | 0.99 kWh | |
Usable volume (litres) |
| 69 | 66 |
Size |
| Large | Large |
Time to cook standard load |
| 38 minutes | 49 minutes |
Surface area of the grid |
| 1400 cm2 | 790 cm2 |
Grill | 2.3 kW |
|
|
Maximum total electrical load at 230V (approximate total including oven lights, oven fan, etc.): 7.4 kW.