Acclaim Lighting 2490 Keep the Stove a Safe Distance From Surrounding Materials, Wall Shields

Page 10

Resolute® Acclaim Woodburning Stove

Keep the Stove a Safe Distance From

Surrounding Materials

Both a stove and its chimney connector radiate heat in all directions when operating. A safe installation re- quires that adequate clearance be maintained between the stove and nearby combustible materials to ensure that such materials do not overheat.

Clearance is the distance between either your stove or chimney connector, and nearby walls, floors, the ceiling, and any other fixed combustible surface. Keep furnish- ings and other combustible materials away from the stove as well. In general, a distance of 48” (1220 mm) must be maintained between the stove and moveable combustible items such as drying clothes, furniture, newspapers, firewood, etc. Keeping those clearance areas empty assures that nearby surfaces and objects will not overheat.

Safe Ways to Reduce Clearances

Your stove has special clearance requirements that have been established after careful research, and test- ing to UL and ULC standards.

Clearance requirements have been established to meet most installation possibilities, and they involve the com- bination of four basic variables:

When the stove has no listed heat shield mounted on it.

When the stove has a listed heat shield mounted on it.

When the wall has no listed heat shield mounted on it.

When the wall has a listed heat shield mounted on it.

In general, the greatest clearance is required when you are placing a stove with no heat shield near a wall with no heat shield. The least clearance is required when both the stove and the wall have heat shields. Reducing a stove clearance may require a listed heat shield on the chimney connector as well.

Clearances may be reduced only by means approved by the regulatory authority, or in accordance with the clearances listed in this manual.

Wall Shields

Wall shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible mate- rial such as 1/2” (13 mm) insulation board or common brick “laid on flat,” with the 3¹⁄₂" (89 mm) side down. (Fig. 13)

Shields must be spaced out from the combustible surface 1" (25 mm) on noncombustible spacers. The spacers should not be directly behind the stove or chim- ney connector.

Air must be able to flow between the wall and the shield. At least 50% of the bottom 1” (25 mm) of the shield should be open and the shield must be open at the top.

When calculating clearance, always measure from the top plate of the stove, or, from the chimney connector itself, to the adjacent combustible surface. Do not mea- sure from the heat shields of the stove or connector to the combustible surface.

Air Flow

 

Screen

 

Wall Shield

 

Stud Wall

 

Framing

 

Noncombustible

 

spacers and

Shield

fasteners

 

 

Metal

Drywall

Spacer

Air Flow

ST248

 

Fig. 13 Approved wall shield construction.

Reversing the Flue Collar

Your Resolute Acclaim is shipped with the flue collar in the top exit position. Depending on your requirements, you may wish to reverse the flue collar and extension plate to the rear exit position. The only tool necessary is a 7/16” wrench.

To reverse the flue collar position:

1.Remove the four (4) fasteners that hold the collar and extension plate. The fasteners are accessible by reaching through the flue collar of the stove.

2.Remove the flue collar and extension plate.

3.Examine the exposed gasket; contact your Vermont Castings Authorized Dealer if the gasket needs to be replaced.

4.Position the extension plate and flue collar in the appropriate orientation, making sure the gasket remains in place. The notched edge of the extension plate should be next to the griddle.

10

2000893

Image 10
Contents Resolute Acclaim Accessories Table of ContentsIntroduction Specifications Resolute Acclaim ModelWhat Kind of Chimney to Use InstallationMasonry Chimneys Prefabricated Chimneys Chimney Connector GuidelinesDouble-wall Chimney Connectors Chimney SizeSecuring the Single-wall Connector To a Masonry Chimney Single-wall Chimney ConnectorsFreestanding Installations Through a Fireplace Above a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection for Fireplace Installation Floor ProtectionWall Shields Keep the Stove a Safe Distance From Surrounding MaterialsSafe Ways to Reduce Clearances Reversing the Flue CollarFireplace Installations 6mmChimney Connector Clearance Resolute Acclaim Clearance ChartParallel Installation Corner Stove Clearance Front Clearance To CombustiblesStove Installed Stove in Corner Parallel to Wall Top Exit, No Heat ShieldsMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Alcove Installations Construction RequirementsUnpack the Stove Install Stove LegsOperation Two Controls Operate the StoveTwo Rules For Success Use the Air Control Settings That Work Best for YouRemovable Andirons For Greater Front-Loading Convenience Burn Only High-Quality FuelAir Setting Air Control Position Primary Air SettingsHow to Build and Sustain a Wood Fire Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Surface Thermometer is a Guide to PerformanceClear the Ash Frequently Rules for Open Fire ViewingRemove and Store Ash Safely Draft Management Fuel Draft TestingCreosote Back-puffingClean the Exhaust Channels MaintenanceCleaning the Glass Care of the Cast Iron SurfaceRepair Missing Cement in Seams Adjust the DoorAdjust the Damper as Needed Avoid Damaging the GlassReplace Broken Glass Immediately How to Replace GasketsResolute Acclaim Gaskets on Moving Parts Replacing the Griddle Gasket Gaskets on Resolute Acclaim Stationary PartsReplacing the Door Gaskets Replace Broken FirebricksDaily Resolute Acclaim Maintenance ScheduleYearly Spring Cleaning Two MonthsResolute Acclaim Woodburning Stove Item Description Part NumberResolute Acclaim Woodburning Stove Ashlip Door LegWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.