Acclaim Lighting 2490 Installation, What Kind of Chimney to Use, Masonry Chimneys

Page 4

Resolute® Acclaim Woodburning Stove

Installation

safety NOTICE: IF YOUR RESOLUTE ACCLAIM IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLATION, OPERA- TION AND MAINTENANCE DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRIC- TIONS AND INSTALLATION INSPECTION REQUIRE- MENTS IN YOUR AREA.

Before you begin an installation, review your plans to see that:

Your stove and chimney connector will be far enough from combustible material to meet all clearance requirements.

The floor protector is large enough and is con- structed properly to meet all requirements.

You have all necessary permits from local author- ities.

Your local building official is the final authority for ap- proving your installation as safe and determining that it meets local and state codes.

The metal label permanently attached to the back of every Vermont Castings stove indicates that it has been tested to current UL and ULC standards, and gives the name of the testing laboratory. Clearance and installa- tion information is also printed on the label. Local au- thorities generally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved.

Codes vary in different areas, however. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.

For any unresolved questions about installation, refer to the National Fire Protection Association’s publication ANSI/NFPA 211–1988 Standard for Chimneys, Fire- places, Vents and Solid Fuel Burning Appliances. In Canada, the equivalent publication is CSA CAN-B365, Installation Code for Solid Fuel Burning Appliances and Equipment. These standards are the basis for many national codes. They are nationally recognized and are accepted by most local authorities. Your local dealer or your local building official may have a copy of these regulations.

Important: Failure to follow these in- stallation instructions may result in a dangerous situation, including a chimney or house fire. Follow all instructions exactly and do not allow makeshift com- promises to endanger property and per- sonal safety.

What Kind of Chimney to Use

Your Resolute Acclaim may be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney. Whatever kind you use, the chimney and chimney connector must be in good condition and kept clean.

If you use an existing masonry chimney, it must be in- spected to ensure safe condition before the stove is in- stalled. Your local professional chimney sweep, building inspector, or fire department official will be able to make the inspection or to direct you to someone who can.

The chimney should extend at least 3’ (914 mm) above the highest point where it passes through a roof, and at least 2’ (610 mm) higher than any portion of a building within 10’ (3m). (Fig. 2)

 

0 To 10’

 

 

2’ Min. 3’

0 To 10’

 

Min.

 

 

 

2’ Min. 3’

 

 

Min.

Reference Point

AC617

 

 

Fig. 2

The 2’-3’-10’ rule for chimneys.

For proper draft and good performance, any chimney used with a Resolute Acclaim should extend at least 16’ (5m) above the flue collar of the stove.

Masonry Chimneys

An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chimney also should be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.

A prefabricated doube-wall insulated chimney

A tile-lined masonry chimney

ST241

Fig. 3 Standard chimney types.

2000893

Image 4
Contents Resolute Acclaim Accessories Table of ContentsIntroduction Specifications Resolute Acclaim ModelWhat Kind of Chimney to Use InstallationMasonry Chimneys Chimney Connector Guidelines Double-wall Chimney ConnectorsPrefabricated Chimneys Chimney SizeSecuring the Single-wall Connector To a Masonry Chimney Single-wall Chimney ConnectorsFreestanding Installations Through a Fireplace Above a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection for Fireplace Installation Floor ProtectionKeep the Stove a Safe Distance From Surrounding Materials Safe Ways to Reduce ClearancesWall Shields Reversing the Flue CollarFireplace Installations 6mmResolute Acclaim Clearance Chart Parallel Installation Corner Stove ClearanceChimney Connector Clearance Front Clearance To CombustiblesStove Installed Stove in Corner Parallel to Wall Top Exit, No Heat ShieldsMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Alcove Installations Construction RequirementsInstall Stove Legs OperationUnpack the Stove Two Controls Operate the StoveUse the Air Control Settings That Work Best for You Removable Andirons For Greater Front-Loading ConvenienceTwo Rules For Success Burn Only High-Quality FuelPrimary Air Settings How to Build and Sustain a Wood FireAir Setting Air Control Position Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Surface Thermometer is a Guide to PerformanceClear the Ash Frequently Rules for Open Fire ViewingRemove and Store Ash Safely Draft Management Draft Testing CreosoteFuel Back-puffingMaintenance Cleaning the GlassClean the Exhaust Channels Care of the Cast Iron SurfaceAdjust the Door Adjust the Damper as NeededRepair Missing Cement in Seams Avoid Damaging the GlassReplace Broken Glass Immediately How to Replace GasketsResolute Acclaim Gaskets on Moving Parts Gaskets on Resolute Acclaim Stationary Parts Replacing the Door GasketsReplacing the Griddle Gasket Replace Broken FirebricksResolute Acclaim Maintenance Schedule Yearly Spring CleaningDaily Two MonthsResolute Acclaim Woodburning Stove Item Description Part NumberResolute Acclaim Woodburning Stove Ashlip Door LegWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.