Acclaim Lighting 2490 Single-wall Chimney Connectors, Freestanding Installations

Page 6

Resolute® Acclaim Woodburning Stove

Single-wall Chimney Connectors

Beginning at the flue collar of the stove, assemble the

chimney connector. Insert the first crimped end into the

stove’s flue collar, and keep each crimped end pointing

toward the stove. Using

the holes in the flue collar

as guides, drill 1/8” (3mm)

holes in the bottom of the

Securing the Single-wall Connector

to a Masonry Chimney

Both freestanding masonry chimneys and fireplace masonry chimneys may be used for installation of your Resolute Acclaim.

first section of chimney

connector and secure it to the flue collar with three

(3)#10 x 1/2” sheet metal screws.

Secure each joint between sections of chim- ney connector, includ-

ing telescoping joints,

 

Fig. 4 The crimped end of

with at least three (3)

the connector points toward

sheet metal screws. The

the stove.

Thimble Sleeve

Chimney

Connector

Flue

Keep sleeve end flush with flue tile

ST243

predrilled holes in the top

of each section of chimney connector serve as guides when you drill 1/8” (3mm) holes in the bottom of the next section.

Secure the chimney connector to the chimney. In- structions for various installations follow.

Be sure the installed stove and chimney connector are correct distances from nearby combustible material. Note: Special slip pipes and thimble sleeves that form telescoping joints between sections of chimney con- nector are available to simplify installations. They often eliminate the need to cut individual connector sections. Consult your local dealer about these special pieces.

Securing the Single-wall Connector

to a Prefabricated Chimney

Follow the installation instructions of the chimney manufacturer exactly as you install the chimney. The manufacturer of the chimney will supply the acces- sories to support the chimney, either from the roof of the house, at the ceiling of the room where the stove is installed, or from an exterior wall.

Special adapters are available from your local dealer to make the connection between the prefabricated chimney and the chimney connector. The top of such adapters attach directly to the chimney or to the chim- ney’s ceiling support package, while the bottom of the adapter is screwed to the chimney connector.

These adapters are designed so the top end will fit outside the inner wall of the chimney, and the bottom end will fit inside the first section of chimney connector. When assembled in this way, any soot or creosote fall- ing from the inner walls of the chimney will stay inside the chimney connector.

Fig. 5 The thimble, made of either cermaic or metal, must be cemented securely in place.

Freestanding Installations

If the chimney connector must pass through a com- bustible wall to reach the chimney, follow the recom- mendations in the Wall Pass-Through section that follows. The opening through the chimney wall to the flue (the “breech”) must be lined with either a ceramic or metal cylinder, called the “thimble”, which is securely cemented in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly. (Fig. 6)

Chimney

Flue Liner

 

Elbow

Flue Liner

 

Slip Pipe

 

Standard

Thimble

 

Connector

 

 

Flue Collar

ST492

Fig. 6 Chimney connection is a freestanding installation.

2000893

Image 6
Contents Resolute Acclaim Table of Contents AccessoriesIntroduction Specifications Resolute Acclaim ModelInstallation What Kind of Chimney to UseMasonry Chimneys Prefabricated Chimneys Chimney Connector GuidelinesDouble-wall Chimney Connectors Chimney SizeSingle-wall Chimney Connectors Securing the Single-wall Connector To a Masonry ChimneyFreestanding Installations Above a Fireplace Through a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection for Fireplace Installation Floor ProtectionWall Shields Keep the Stove a Safe Distance From Surrounding MaterialsSafe Ways to Reduce Clearances Reversing the Flue CollarFireplace Installations 6mmChimney Connector Clearance Resolute Acclaim Clearance ChartParallel Installation Corner Stove Clearance Front Clearance To CombustiblesStove Installed Stove in Corner Parallel to Wall Top Exit, No Heat ShieldsMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Alcove Installations Construction RequirementsUnpack the Stove Install Stove LegsOperation Two Controls Operate the StoveTwo Rules For Success Use the Air Control Settings That Work Best for YouRemovable Andirons For Greater Front-Loading Convenience Burn Only High-Quality FuelAir Setting Air Control Position Primary Air SettingsHow to Build and Sustain a Wood Fire Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Surface Thermometer is a Guide to PerformanceRules for Open Fire Viewing Clear the Ash FrequentlyRemove and Store Ash Safely Draft Management Fuel Draft TestingCreosote Back-puffingClean the Exhaust Channels MaintenanceCleaning the Glass Care of the Cast Iron SurfaceRepair Missing Cement in Seams Adjust the DoorAdjust the Damper as Needed Avoid Damaging the GlassHow to Replace Gaskets Replace Broken Glass ImmediatelyResolute Acclaim Gaskets on Moving Parts Replacing the Griddle Gasket Gaskets on Resolute Acclaim Stationary PartsReplacing the Door Gaskets Replace Broken FirebricksDaily Resolute Acclaim Maintenance ScheduleYearly Spring Cleaning Two MonthsResolute Acclaim Woodburning Stove Item Description Part NumberResolute Acclaim Woodburning Stove Ashlip Door LegWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.