Acclaim Lighting 2490 Removable Andirons For Greater Front-Loading Convenience

Page 18

Resolute® Acclaim Woodburning Stove

Removable Andirons For Greater

Front-Loading Convenience

The andirons slip into pockets cast into the front of the bottom grate and can be removed when loading through the front door. (Most Acclaim owners, however, prefer the convenience of “smokeless” top loading.)

Important: The andirons must be in place during operation. (Fig. 28) They not only help keep the glass door panel clear for fireviewing, but they assure proper placement of the fuel load for efficient clean-burning operation.

Firebricks

Secondary Air

Ports

Removable

Ash Pan

Andirons

 

ST612

Bottom Crates

Fig. 28 A look inside the firebox of the Resolute Acclaim.

Two Rules For Success

Burning wood is said to be more of an art than a sci- ence. You’ll easily master the art if you start by using good, dry fuel, and understand how the stove’s air sup- ply system operates.

Burn Only High-Quality Fuel

This heater is designed to burn natural wood only; do not burn fuels other than those for which this heater was designed.

Higher efficiencies and lower emissions generally result when burning air-dried, seasoned woods as compared to softwoods or freshly cut hardwoods. Avoid burning “green” wood that has not been properly seasoned. Also, do not use construction materials or trash as fuel; the chemicals, coatings and hardware that may be present can cause damage to the refractory material.

The best hardwood fuels include oak, maple, beech, ash, and hickory that has been split, stacked, and air- dried outside under cover for at least one year. Avoid burning cordwood that is over 2 years old as such fuel can contribute to short burn times, backpuffing and over-firing.

For areas that do not have a supply of hardwood, some of the better softwoods that are commonly burned include tamarack, yellow pine, white pine, Eastern red cedar, fir, and redwood. They too should be properly dried. The length of the wood should be 16” (406 mm). Use of wood shorter than 16” may result in decreased burn times.

Wood should be stored under cover to maintain dry- ness. Even for short-term storage, keep wood a safe distance from the heater and keep it out of the areas around the heater used for refueling and ash removal.

Use the Air Control Settings

That Work Best for You

No single control setting will fit every situation. Each operation will differ depending on the quality of the fuel, the amount of heat desired, and how long you wish the fire to burn.

Control settings also depend on your particular instal- lation’s “draft,” or the force that moves air through the stove and up through the chimney. Draft is affected by such things as the length, type, and location of the chimney, local geography, nearby obstructions, and other factors.

Too much draft may cause excessive temperatures in the stove. On the other hand, too little draft can cause backpuffing into the room and/or insufficient heat.

How do you know if your draft is excessively high or low? Symptoms of too much draft include an uncontrol- lable burn or a part of the stove or chimney connector glowing red. Inadequate draft is indicated by smoke leaking into the room through the stove or chimney con- nector joints.

In some newer homes that are well-insulated and weather-tight, poor draft may result from insufficient air in the house. In such cases it may be necessary to duct combustion air to the stove directly from outside. In fact, in some areas, outside combustion air is required for stove installations in all new construction.

Your Resolute Acclaim is designed to easily incorporate outside combustion air with a Vermont Castings Out- side Air Duct Adapter #3255 available from your local dealer.

When first using the stove, keep track of the air control settings. You will quickly find that a specific setting will give you a fixed amount of heat. It may take a week or two to determine the amount of heat and the length of burn you should expect from various settings.

Most installations do not require a large amount of com- bustion air, especisally if adequate draft is available. Do not for any reason attempt to increase the firing rate of your heater by altering the air control adjustment range outlined in these directions.

18

2000893

Image 18
Contents Resolute Acclaim Table of Contents AccessoriesIntroduction Specifications Resolute Acclaim ModelInstallation What Kind of Chimney to UseMasonry Chimneys Prefabricated Chimneys Chimney Connector GuidelinesDouble-wall Chimney Connectors Chimney SizeSingle-wall Chimney Connectors Securing the Single-wall Connector To a Masonry ChimneyFreestanding Installations Above a Fireplace Through a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection for Fireplace Installation Floor ProtectionWall Shields Keep the Stove a Safe Distance From Surrounding MaterialsSafe Ways to Reduce Clearances Reversing the Flue CollarFireplace Installations 6mmChimney Connector Clearance Resolute Acclaim Clearance ChartParallel Installation Corner Stove Clearance Front Clearance To CombustiblesStove Installed Stove in Corner Parallel to Wall Top Exit, No Heat ShieldsMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Alcove Installations Construction RequirementsUnpack the Stove Install Stove LegsOperation Two Controls Operate the StoveTwo Rules For Success Use the Air Control Settings That Work Best for YouRemovable Andirons For Greater Front-Loading Convenience Burn Only High-Quality FuelAir Setting Air Control Position Primary Air SettingsHow to Build and Sustain a Wood Fire Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Surface Thermometer is a Guide to PerformanceRules for Open Fire Viewing Clear the Ash FrequentlyRemove and Store Ash Safely Draft Management Fuel Draft TestingCreosote Back-puffingClean the Exhaust Channels MaintenanceCleaning the Glass Care of the Cast Iron SurfaceRepair Missing Cement in Seams Adjust the DoorAdjust the Damper as Needed Avoid Damaging the GlassHow to Replace Gaskets Replace Broken Glass ImmediatelyResolute Acclaim Gaskets on Moving Parts Replacing the Griddle Gasket Gaskets on Resolute Acclaim Stationary PartsReplacing the Door Gaskets Replace Broken FirebricksDaily Resolute Acclaim Maintenance ScheduleYearly Spring Cleaning Two MonthsResolute Acclaim Woodburning Stove Item Description Part NumberResolute Acclaim Woodburning Stove Ashlip Door LegWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.